Noise spectrum analysis of superconducting kinetic inductance detectors

被引:1
|
作者
Shi, Zhong-Yu [1 ]
Dai, Xu-Cheng [1 ]
Wang, Hao-Yu [2 ,3 ]
Mai, Zhan-Zhang [1 ]
Ouyang, Peng-Hui [4 ]
Wang, Yi-Zhuo [4 ]
Chai, Ya-Qiang [4 ]
Wei, Lian-Fu [4 ]
Liu, Xu-Ming [3 ]
Pan, Chang-Zhao [2 ,3 ]
Guo, Wei-Jie [2 ,3 ]
Shu, Shi-Bo [5 ]
Wang, Yi-Wen [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Phys Sci & Technol, Quantum Optoelect Lab, Chengdu 610031, Peoples R China
[2] Southern Univ Sci & Technol, Shenzhen Inst Quantum Sci & Engn, Shenzhen 518055, Peoples R China
[3] Int Quantum Acad, Shenzhen 518048, Peoples R China
[4] Southwest Jiaotong Univ, Sch Informat Sci & Technol, Informat Quantum Technol Lab, Chengdu 610031, Peoples R China
[5] Chinese Acad Sci, Key Lab Particle Astrophys, Inst High Energy Phys, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
kinetic inductance detectors; superconducting resonator; noise spectrum;
D O I
10.7498/aps.73.20231504
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
As a newly developed pair-breaking superconducting detector, microwave kinetic inductance detectors aresimple to integrate in the frequency domain and have already been used in astronomical detection and arrayimaging at the (sub)millimeter and optical wavelengths. For these applications, the dark noise level of kineticinductance detector is one of the key performance indicators. Herein a noise power spectrum analysis method isintroduced in detail, which can accurately and effectively analyze the noise spectrum of kinetic inductancedetector in a wide frequency range. This method can well balance the noise spectrum resolution and varianceperformance, by taking the noise data at the resonance frequency with two sampling rates and setting theappropriate frequency resolutions for different frequency bands. This method is used to characterize andcompare the noise of aluminum (Al) kinetic inductance detectors made from two different micromachiningprocesses. We deposite a 25-nm-thick aluminum film on high-resistivity silicon substrate for one device, whileplace one silicon nitride (SiNx) film on the top and one on the bottom of the aluminum film for another device.It is found that the frequency noise of the device with two silicon nitride films is about 25% to 50% of the barealuminum device. Using this double silicon nitride film fabrication technique, we further fabricate a few groupsof lumped-element aluminum kinetic inductance detectors with various inductor and interdigitated capacitordesigns. We investigate the noise properties of these devices at different microwave driven power and bathtemperatures, and the experimental results show typical two-level system noise behaviors. Our work provides astandard method to characterize the noise power spectrum of kinetic inductor detector, and also paves the wayto developing low-noise aluminum kinetic inductance detectors for terahertz imaging, photon-counting andenergy-resolving applications
引用
收藏
页数:9
相关论文
共 32 条
  • [21] Mazin BA, 2002, AIP CONF PROC, V605, P309, DOI 10.1063/1.1457652
  • [22] Granular superconductors for high kinetic inductance and low loss quantum devices
    Moshe, Aviv Glezer
    Farber, Eli
    Deutscher, Guy
    [J]. APPLIED PHYSICS LETTERS, 2020, 117 (06)
  • [23] Noroozian O, 2009, AIP CONF PROC, V1185, P148, DOI 10.1063/1.3292302
  • [24] Calibration and performance of the NIKA2 camera at the IRAM 30-m Telescope
    Perotto, L.
    Ponthieu, N.
    Macias-Perez, J. F.
    Adam, R.
    Ade, P.
    Andre, P.
    Andrianasolo, A.
    Aussel, H.
    Beelen, A.
    Benoit, A.
    Berta, S.
    Bideaud, A.
    Bourrion, O.
    Calvo, M.
    Catalano, A.
    Comis, B.
    De Petris, M.
    Desert, F. -X.
    Doyle, S.
    Driessen, E. F. C.
    Garcia, P.
    Gomez, A.
    Goupy, J.
    John, D.
    Keruzore, F.
    Kramer, C.
    Ladjelate, B.
    Lagache, G.
    Leclercq, S.
    Lestrade, J. -F.
    Maury, A.
    Mauskopf, P.
    Mayet, F.
    Monfardini, A.
    Navarro, S.
    Penalver, J.
    Pierfederici, F.
    Pisano, G.
    Reveret, V.
    Ritacco, A.
    Romero, C.
    Roussel, H.
    Ruppin, F.
    Schuster, K.
    Shu, S.
    Sievers, A.
    Tucker, C.
    Zylka, R.
    [J]. ASTRONOMY & ASTROPHYSICS, 2020, 637
  • [25] DIGITAL INTERPOLATION BEAMFORMING FOR LOW-PASS AND BANDPASS SIGNALS
    PRIDHAM, RG
    MUCCI, RA
    [J]. PROCEEDINGS OF THE IEEE, 1979, 67 (06) : 904 - 919
  • [26] Terahertz superconducting kinetic inductance detectors demonstrating photon-noise-limited performance and intrinsic generation-recombination noise
    Shi, Qing
    Li, Jing
    Zhi, Qiang
    Wang, Zheng
    Miao, Wei
    Shi, Sheng-Cai
    [J]. SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2022, 65 (03)
  • [27] Ultrastable millimeter-wave kinetic inductance detectors
    Vissers, M. R.
    Austermann, J. E.
    Malnou, M.
    McKenney, C. M.
    Dober, B.
    Hubmayr, J.
    Hilton, G. C.
    Ullom, J. N.
    Gao, J.
    [J]. APPLIED PHYSICS LETTERS, 2020, 116 (03)
  • [28] Proximity-coupled Ti/TiN multilayers for use in kinetic inductance detectors
    Vissers, Michael R.
    Gao, Jiansong
    Sandberg, Martin
    Duff, Shannon M.
    Wisbey, David S.
    Irwin, Kent D.
    Pappas, David P.
    [J]. APPLIED PHYSICS LETTERS, 2013, 102 (23)
  • [29] USE OF FAST FOURIER TRANSFORM FOR ESTIMATION OF POWER SPECTRA - A METHOD BASED ON TIME AVERAGING OVER SHORT MODIFIED PERIODOGRAMS
    WELCH, PD
    [J]. IEEE TRANSACTIONS ON AUDIO AND ELECTROACOUSTICS, 1967, AU15 (02): : 70 - +
  • [30] Thermal-sensitive superconducting coplanar waveguide resonator used for weak light detection
    Zhou Pin-Jia
    Wang Yi-Wen
    Wei Lian-Fu
    [J]. ACTA PHYSICA SINICA, 2014, 63 (07)