Quantitative evaluation of scatter correction in 128-slice fan-beam computed tomography scan using geant4 application for tomographic emission Monte Carlo simulation

被引:0
作者
Azinkhah, Iman [1 ]
Sadeghi, Mahdi [1 ,4 ]
Sheikhzadeh, Peyman [2 ]
Malekzadeh, Malakeh [3 ]
机构
[1] Iran Univ Med Sci, Finetech Med Res Ctr, Sch Med, Dept Med Phys, Tehran, Iran
[2] Univ Tehran Med Sci, Imam Khomeini Hosp Complex, Dept Nucl Med, Tehran, Iran
[3] Iran Univ Med Sci, Sch Med, Dept Med Phys, Tehran, Iran
[4] Iran Univ Med Sci, Sch Med, Dept Med Phys, POB 14155-6183, Tehran, Iran
关键词
Correction; computed tomography; geant4 application for tomographic emission; scatter; GENERAL FRAMEWORK; RADIATION; REDUCTION; TOOLKIT;
D O I
10.4103/jmss.jmss_71_22
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Simulation of tomographic imaging systems with fan-beam geometry, estimation of scattered beam profile using Monte Carlo techniques, and scatter correction using estimated data have always been new challenges in the field of medical imaging. The most important aspect is to ensure the results of the simulation and the accuracy of the scatter correction. This study aims to simulate 128-slice computed tomography (CT) scan using the Geant4 Application for Tomographic Emission (GATE) program, to assess the validity of this simulation and estimate the scatter profile. Finally, a quantitative comparison of the results is made from scatter correction. Methods: In this study, 128-slice CT scan devices with fan-beam geometry along with two phantoms were simulated by GATE program. Two validation methods were performed to validate the simulation results. The data obtained from scatter estimation of the simulation was used in a projection-based scatter correction technique, and the post-correction results were analyzed using four quantities, such as: pixel intensity, CT number inaccuracy, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR). Results: Both validation methods have confirmed the appropriate accuracy of the simulation. In the quantitative analysis of the results before and after the scatter correction, it should be said that the pixel intensity patterns were close to each other, and the accuracy of the CT scan number reached <10%. Moreover, CNR and SNR have increased by more than 30%-65% respectively in all studied areas. Conclusion: The comparison of the results before and after scatter correction shows an improvement in CNR and SNR while a reduction in cupping artifact according to pixel intensity pattern and enhanced CT number accuracy.
引用
收藏
页码:280 / 289
页数:10
相关论文
共 37 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   The PENELOPE Physics Models and Transport Mechanics. Implementation into Geant4 [J].
Asai, Makoto ;
Cortes-Giraldo, Miguel A. ;
Gimenez-Alventosa, Vicent ;
Gimenez Gomez, Vicent ;
Salvat, Francesc .
FRONTIERS IN PHYSICS, 2021, 9
[3]   Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam x-ray CT [J].
Ay, MR ;
Zaidi, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20) :4863-4885
[4]  
Baer M, 2012, e-Journal Nondestr Test, P17
[5]   AN ANALYTICAL MODEL OF THE SCATTERED RADIATION DISTRIBUTION IN DIAGNOSTIC-RADIOLOGY [J].
BOONE, JM ;
SEIBERT, JA .
MEDICAL PHYSICS, 1988, 15 (05) :721-725
[6]   ROOT - An object oriented data analysis framework [J].
Brun, R ;
Rademakers, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 389 (1-2) :81-86
[7]   PHYSICAL CHARACTERISTICS OF SCATTERED RADIATION IN DIAGNOSTIC-RADIOLOGY - MONTE-CARLO SIMULATION STUDIES [J].
CHAN, HP ;
DOI, K .
MEDICAL PHYSICS, 1985, 12 (02) :152-165
[8]   Accelerated simulation of cone beam X-ray scatter projections [J].
Colijn, AP ;
Beekman, FJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) :584-590
[9]  
Darmian AN, 2011, IEEE NUCL SCI CONF R, P2692, DOI 10.1109/NSSMIC.2011.6152951
[10]   Scatter correction method for x-ray CT using primary modulation: Phantom studies [J].
Gao, Hewei ;
Fahrig, Rebecca ;
Bennett, N. Robert ;
Sun, Mingshan ;
Star-Lack, Josh ;
Zhu, Lei .
MEDICAL PHYSICS, 2010, 37 (02) :934-946