Transarterial Embolization of Ruptured Pancreaticoduodenal Artery Pseudoaneurysm Related to Chronic Pancreatitis

被引:2
作者
Marginean, Lucian [1 ,2 ]
Muresan, Adrian Vasile [3 ,4 ]
Arbanasi, Emil Marian [2 ,3 ,4 ]
Cosarca, Catalin Mircea [3 ,5 ]
Arbanasi, Eliza Mihaela [6 ]
Russu, Eliza [3 ,4 ]
Filep, Rares Cristian [1 ]
Kaller, Reka [2 ,3 ,4 ]
机构
[1] Mures Cty Emergency Hosp, Dept Radiol, Targu Mures 540136, Romania
[2] George Emil Palade Univ Med Pharm Sci & Technol T, Doctoral Sch Med & Pharm, Targu Mures 540142, Romania
[3] Mures Cty Emergency Hosp, Clin Vasc Surg, Targu Mures 540136, Romania
[4] George Emil Palade Univ Med Pharm Sci & Technol T, Dept Vasc Surg, Targu Mures 540139, Romania
[5] George Emil Palade Univ Med Pharm Sci & Technol T, Dept Anat, Targu Mures 540139, Romania
[6] George Emil Palade Univ Med Pharm Sci & Technol T, Fac Pharm, Targu Mures 540139, Romania
关键词
pseudoaneurysms; embolization; pancreaticoduodenal artery; choils; CTA; PDA; ENDOVASCULAR TREATMENT; COIL EMBOLIZATION; ANEURYSM; MANAGEMENT;
D O I
10.3390/diagnostics13061090
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We presented a 67-year-old woman with lightheadedness, diaphoresis, and acute epigastric and right hypochondrium pain, with a past medical history including stage 2 essential hypertension, chronic ischemic cardiomyopathy, and class 1 obesity. An abdominal contrast-enhanced CT scan showed an extensive hematoma (3 x 4 cm(2) in size) located intra-abdominally, adjacent to the duodenojejunal area, with hyperdensity around the duodenum, positioned inferior to the pancreas (30-59 HU). Moreover, the CT scan also revealed an enhancing lesion as a pseudoaneurysm of the inferior pancreaticoduodenal artery, measuring 5 x 8 x 8 mm(3) with active bleeding and associated hematoma. Following these investigations of the abdominal area, a decision was made to proceed with an endovascular intervention within the interventional radiology department. With the patient under conscious sedation, via a right common femoral artery approach, the superior mesenteric artery was catheterized. While injecting the contrast agent to obtain a better working projection, the pseudoaneurysm ruptured, and acute extravasation of the contrast agent was noted, followed by injection of a mixture of 1 mL Glubran 2 with 2 mL Lipiodol until complete obliteration of the pseudoaneurysm was obtained. The patient was hemodynamically stable at the end of the procedure and was discharged 6 days later in a good condition without active bleeding signs.
引用
收藏
页数:6
相关论文
共 42 条
[1]   Computed Tomography Angiography Markers and Intraluminal Thrombus Morphology as Predictors of Abdominal Aortic Aneurysm Rupture [J].
Arbanasi, Emil Marian ;
Muresan, Adrian Vasile ;
Cosarca, Catalin Mircea ;
Arbanasi, Eliza Mihaela ;
Niculescu, Raluca ;
Voidazan, Septimiu Toader ;
Ivanescu, Adrian Dumitru ;
Halmaciu, Ioana ;
Filep, Rarel Cristian ;
Marginean, Lucian ;
Suzuki, Shuko ;
Chirila, Traian, V ;
Kaller, Reka ;
Russu, Eliza .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (23)
[2]   Late Rupture of a Thrombosed Aortic Abdominal Aneurysm - a Case Report [J].
Arbanasi, Emil-Marian ;
Russu, Eliza ;
Muresan, Adrian Vasile ;
Arbanasi, Eliza-Mihaela .
JOURNAL OF CARDIOVASCULAR EMERGENCIES, 2021, 7 (03) :84-87
[3]   Replaced right hepatic artery pseudoaneurysm managed with coil embolisation [J].
Bains, Lovenish ;
Kori, Ronal ;
Sharma, Raman ;
Kaur, Daljit .
BMJ CASE REPORTS, 2019, 12 (09)
[4]  
Bradley Sara, 2019, Clin Pract Cases Emerg Med, V3, P132, DOI 10.5811/cpcem.2019.1.41057
[5]   Current management of visceral artery aneurysms [J].
Carr, SC ;
Pearce, WH ;
Vogelzang, RL ;
McCarthy, WJ ;
Nemcek, AA ;
Yao, JST .
SURGERY, 1996, 120 (04) :627-633
[6]   Endovascular Use of Cyanoacrylate-Lipiodol Mixture for Peripheral Embolization: Properties, Techniques, Pitfalls, and Applications [J].
Comby, Pierre-Olivier ;
Guillen, Kevin ;
Chevallier, Olivier ;
Lenfant, Marc ;
Pellegrinelli, Julie ;
Falvo, Nicolas ;
Midulla, Marco ;
Loffroy, Romaric .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (19)
[7]   Giant Celiac Artery Aneurysm Treated with a Flow-Diverting Multilayer Stent: Early Rupture as a Fatal Complication [J].
Coskun, Bilgen ;
Rozanes, Izzet ;
Erkan, Mert ;
Ates, Sanser ;
Akpek, Sergin .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (03) :468-470
[8]   Spontaneous inferior pancreaticoduodenal artery pseudoaneurysm rupture [J].
Dallara, Heidi ;
Habboushe, Joseph .
INTERNAL AND EMERGENCY MEDICINE, 2017, 12 (08) :1319-1321
[9]   Operative management of hepatic artery aneurysms [J].
Erben, Young ;
De Martino, Randall R. ;
Bjarnason, Haraldur ;
Duncan, Audra A. ;
Kalra, Manju ;
Oderich, Gustavo S. ;
Bower, Thomas C. ;
Gloviczki, Peter .
JOURNAL OF VASCULAR SURGERY, 2015, 62 (03) :610-615
[10]   Inferior pancreaticoduodenal artery pseudoaneurysm rupture caused by the pancreatic neuroendocrine tumor [J].
Fukami, Yasuyuki ;
Saito, Takuya ;
Arikawa, Takashi ;
Osawa, Takaaki ;
Komatsu, Shunichiro ;
Kaneko, Kenitiro ;
Suzuki, Kojiro ;
Takahashi, Emiko ;
Tsuzuki, Toyonori ;
Sano, Tsuyoshi .
SURGERY, 2020, 168 (01) :E1-E2