Investigation of LASSO Regression Method as a Correction Measurements' Factor for Low-Cost Air Quality Sensors

被引:7
作者
Christakis, Ioannis [1 ]
Sarri, Elena [1 ]
Tsakiridis, Odysseas [1 ]
Stavrakas, Ilias [1 ]
机构
[1] Univ West Attica, Fac Engn, Dept Elect & Elect Engn, Elect Devices & Mat Lab, Thivon Av 250, GR-12241 Athens, Greece
关键词
ozone (O-3); nitrogen dioxide (NO2); air quality IoT; low-cost sensing systems; optimization low-cost sensors measurements; LASSO regression; FIELD CALIBRATION; AVAILABLE SENSORS; MONITORING; PART; POLLUTION; PERFORMANCE; NETWORKS; CLUSTER; OZONE; MODEL; NO;
D O I
10.3390/signals5010004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Air quality is a subject of study, particularly in densely populated areas, as it has been shown to affect human health and the local ecosystem. In recent years, with the rapid development of technology, low-cost sensors have emerged, with many people interested in the quality of the air in their area turning to the procurement of such sensors as they are affordable. The reliability of measurements from low-cost sensors remains a question in the research community. In this paper, the determination of the correction factor of low-cost sensor measurements by applying the least absolute shrinkage and selection operator (LASSO) regression method is investigated. The results are promising, as following the application of the correction factor determined through LASSO regression the adjusted measurements exhibit a closer alignment with the reference measurements. This approach ensures that the measurements from low-cost sensors become more reliable and trustworthy.
引用
收藏
页码:60 / 86
页数:27
相关论文
共 43 条
[1]  
AAN, Alphasense Application Note AAN 104 How Electrochemical Gas Sensors Work
[2]   Using Low-Cost Air Quality Sensor Networks to Improve the Spatial and Temporal Resolution of Concentration Maps [J].
Ahangar, Faraz Enayati ;
Freedman, Frank R. ;
Venkatram, Akula .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (07)
[3]  
Alphasense, 2014, Alphasense Application Note AAN 803-01 Correcting for Background Currents in Four Electrode Toxic Gas Sensors
[4]  
Alphasense UK, Browse Gas Sensors & Air Quality Monitors
[5]  
[Anonymous], AMB OUTD AIR POLL
[6]  
[Anonymous], AIR POLLUTION MEASUR
[7]  
[Anonymous], PMS5003-LaserPM2.5 Sensor-Plantower Technology
[8]   Cross-sensitivities of electrochemical detectors used to monitor worker exposures to airborne contaminants: False positive responses in the absence of target analytes [J].
Austin, CC ;
Roberge, B ;
Goyer, N .
JOURNAL OF ENVIRONMENTAL MONITORING, 2006, 8 (01) :161-166
[9]  
Barcelo-Ordinas JM, 2018, IEEE WCNC
[10]   Performance of NO, NO2 low cost sensors and three calibration approaches within a real world application [J].
Bigi, Alessandro ;
Mueller, Michael ;
Grange, Stuart K. ;
Ghermandi, Grazia ;
Hueglin, Christoph .
ATMOSPHERIC MEASUREMENT TECHNIQUES, 2018, 11 (06) :3717-3735