Theoretical and experimental investigation on the effects of internal heat exchangers on a reversible automobile R744 air-conditioning system under various operating conditions

被引:5
作者
Zhang, Wenying [1 ]
Li, Wenzhe [1 ,2 ]
Cernicin, Vladimir [3 ]
Hrnjak, Pega [1 ,4 ]
机构
[1] Univ Illinois, ACRC, Urbana, IL 61820 USA
[2] Cent South Univ, Sch Energy Sci & Engn, Changsha 410083, Peoples R China
[3] Univ Belgrade, Fac Mech Engn, Belgrade, Serbia
[4] Creat Thermal Solut Inc, Urbana, IL USA
关键词
R744; Reversible Automobile System; Air-conditioning; Internal Heat Exchanger; Optimization; POSSIBLE ADVANTAGE; CO2; CYCLE; PERFORMANCE; FLOW;
D O I
10.1016/j.applthermaleng.2023.121569
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a theoretical cycle analysis and an experimental study of the effects of internal heat exchangers (IHXs) on reversible automobile R744 air conditioning systems. The cycle analysis shows that the system efficiency benefits most with a high-efficiency IHX in the transcritical mode where the gas cooler exit temperature is high, while the IHX generally has a trivial or even negative effect on the system performance in the subcritical mode. The experimental results reveal that with the IHX, the optimal refrigerant charge is reduced from 1450 g to 1300 g, and the optimal high-side pressure is reduced by 0.24 to 0.67 MPa. Moreover, for both basic and IHX systems, it is experimentally confirmed that one linear control equation can relate the COPmaximizing high-side pressure with the gas-cooler/condenser exit temperature and functions well in both trans- and subcritical modes. That reveals the potential of combing the high-side pressure control in the transcritical mode and the subcooling control in the subcritical mode. Agreed with the theoretical analysis, the IHX has a negligible effect on COP in the subcritical mode in the experiments, while it improves the system efficiency by up to 13.8% in the transcritical mode. The highest benefit is gained in the pull-down condition that has high ambient and cabin temperatures and requires fast cooling.
引用
收藏
页数:12
相关论文
共 37 条
[1]   A criterion for predicting the possible advantage of adopting a suction/liquid heat exchanger in refrigerating system [J].
Aprea, C ;
Ascani, M ;
de Rossi, F .
APPLIED THERMAL ENGINEERING, 1999, 19 (04) :329-336
[2]  
Bittle R.R., 1994, An experimental evaluation of capillary tubesuction line heat exchanger performance with alternative refrigerants HFC-134a and HFC-152a
[3]  
Boewe D, 1999, SAE Tech Pap, DOI [10.4271/1999-01-0583, DOI 10.4271/1999-01-0583]
[4]   Contribution of internal heat exchanger to transcritical R-744 cycle performance [J].
Boewe, DE ;
Bullard, CW ;
Yin, JM ;
Hrnjak, PS .
HVAC&R RESEARCH, 2001, 7 (02) :155-168
[5]   Experimental investigation on the influence of internal heat exchanger in a transcritical CO2 heat pump water heater [J].
Cao, Feng ;
Ye, Zuliang ;
Wang, Yikai .
APPLIED THERMAL ENGINEERING, 2020, 168
[6]   Theoretical analysis of internal heat exchanger in transcritical CO2 heat pump systems and its experimental verification [J].
Cao, Feng ;
Wang, Yikai ;
Ye, Zuliang .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 106 :506-516
[7]  
Cernicin V., 2022, Paper 2305
[8]   Cooling performance of a variable speed CO2 cycle with an electronic expansion valve and internal heat exchanger [J].
Cho, Honghyun ;
Ryu, Changgi ;
Kim, Yongchan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (04) :664-671
[9]   EVALUATION OF SUCTION-LINE LIQUID-LINE HEAT-EXCHANGE IN THE REFRIGERATION CYCLE [J].
DOMANSKI, PA ;
DIDION, DA ;
DOYLE, JP .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1994, 17 (07) :487-493
[10]   Cooling performance enhancement for the automobile transcritical CO2 air conditioning system with various internal heat exchanger effectiveness [J].
Fang, Jianmin ;
Yin, Xiang ;
Wang, Anci ;
Sun, Xifeng ;
Liu, Yuxuan ;
Cao, Feng .
APPLIED THERMAL ENGINEERING, 2021, 196