The monolithic coupling of straight tube Coriolis mass flowmeter with liquid hydrogen

被引:1
|
作者
Pei, Xiangxiang [1 ]
Chen, Qiangfeng [2 ]
Sun, Shien [3 ]
Song, Yucai [2 ]
Qiu, Limin [1 ]
Zhang, Xiaobin [1 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Peoples R China
[2] Zhejiang Zheneng Fuxing Fuel Co Ltd, Hangzhou 310003, Peoples R China
[3] Zhejiang Energy Technol Res Inst Co Ltd, Hangzhou 310003, Peoples R China
关键词
Coriolis mass flowmeter; Liquid hydrogen; Fluid-structure interaction; Monolithic coupling method; Flow-induced vibration;
D O I
10.1016/j.cryogenics.2022.103625
中图分类号
O414.1 [热力学];
学科分类号
摘要
The Coriolis mass flowmeter (CMF) has the advantages of a simple structure and direct measurement of fluid mass flow rate. This paper numerically simulates the fluid-structure interaction (FSI) of a straight tube CMF based on the monolithic coupling methods of hydrodynamics and structural mechanics with liquid hydrogen (LH2) as the working fluid. The simulated time lag for the CMF with water is firstly compared with the results from the published experiment and the iterative partitioned coupling method to validate the model. The com-parison shows that the results of the monolithic coupling are closer to the experimental results. Then the monolithic coupling method is used to analyze the FSI characteristics of the CMF with LH2. And the general flow -induced vibration results with LH2 are presented for the straight tube CMF, including the dry and wet vibration modes. The velocity and the detector positions on the time lag are specially discussed. The results reveal the FSI characteristics of the straight tube CMF with LH2.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A Novel Drive Scheme of Coriolis Mass Flowmeter Based on Adaptive Fuzzy Sliding Mode Control
    Ren, Jianxin
    Zhang, Rui
    Zang, Tian
    Yang, Xinghui
    Tang, Xiaodong
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL, CONTROL AND AUTOMATION ENGINEERING (ECAE 2017), 2017, 140 : 133 - 137
  • [32] HIGH-PRECISION CORIOLIS MASS FLOWMETER FOR BULK MATERIAL 2-PHASE FLOWS
    DIMACZEK, G
    FASSBINDER, HG
    EMMEL, A
    KUPFER, R
    FLOW MEASUREMENT AND INSTRUMENTATION, 1994, 5 (04) : 295 - 302
  • [33] A method for signal processing of Coriolis mass flowmeter based on combining AR model spectrum estimation with DFT
    Niu Penghhui
    Tu Yaqing
    2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, : 1417 - +
  • [34] A novel coriolis mass flowmeter signal processing method based on adaptive notch filter and Hilbert transform
    Shen Ting'ao
    Chen Liwei
    Huang Siyu
    Zhang Peili
    ENERGY REPORTS, 2022, 8 : 265 - 272
  • [35] A Novel Signal Processing Method for Coriolis Mass Flowmeter Based on Time-varying Signal Model
    Zhang, Haitao
    Tu, Yaqing
    Liu, Liangbing
    Niu, Penghui
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 6887 - +
  • [36] Experimental Study and Implementation of a Novel Digital Closed-Loop Control System for Coriolis Mass Flowmeter
    Hu, Chun
    Zheng, Dezhi
    Fan, Shangchun
    IEEE SENSORS JOURNAL, 2013, 13 (08) : 3032 - 3038
  • [37] Simulation and performance analysis of the perforated plate flowmeter for liquid hydrogen
    Jin, Tao
    Tian, Hong
    Gao, Xu
    Liu, Yuanliang
    Wang, Jie
    Chen, Hong
    Lan, Yuqi
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (06) : 3890 - 3898
  • [38] Multiple Adaptive Notch Filters Based A Time-varying Frequency Tracking Method for Coriolis Mass Flowmeter
    Su, F. -H.
    Tu, Y. -Q.
    Zhang, H. -T.
    Xu, Hua
    Shen, T. -A.
    2010 8TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2010, : 6782 - 6786
  • [40] Failure analysis of a titanium Coriolis mass flow meter: A case of hydrogen embrittlement
    Santos, I. G. R.
    Vacchi, G. S.
    Silva, R.
    Kugelmeier, C. L.
    Magalhaes, D. C. C.
    Campesan, G. R.
    Rovere, C. A. D.
    ENGINEERING FAILURE ANALYSIS, 2020, 115