Acceleration Factors for Combined-Accelerated Stress Testing of Photovoltaic Modules

被引:6
作者
Hacke, Peter [1 ]
Owen-Bellini, Michael [1 ]
Kempe, Michael D. [1 ]
Sulas-Kern, Dana B. [1 ]
Miller, David C. [1 ]
Jankovec, Marko [2 ]
Mitterhofer, Stefan [2 ]
Topic, Marko [2 ]
Spataru, Sergiu [3 ]
Gambogi, William [4 ]
Tanahashi, Tadanori [5 ]
机构
[1] Natl Renewable Energy Lab, Reliabil & Syst Performance, Golden, CO 80401 USA
[2] Univ Ljubljana, Fac Engn, Ljubljana 1000, Slovenia
[3] Tech Univ Denmark, Dept Elect & Photon Engn, DK-4000 Roskilde, Denmark
[4] DuPont Cent Res & Dev, Photovolta & Adv Mat, Wilmington, DE 19803 USA
[5] Natl Inst Adv Ind Sci & Technol, Renewable Energy Res Ctr, Koriyama 9630298, Japan
关键词
accelerated testing; durability; photovoltaic modules; reliability; DEGRADATION;
D O I
10.1002/solr.202300068
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Combined-accelerated stress testing (C-AST) is developed to establish the durability of photovoltaic (PV) products, including for degradation modes that are not a priori known or examined in standardized tests. C-AST aims to comprehensively represent the sample, stress factors, and their combinations using levels at the statistical tails of the natural environment. Acceleration factors for relevant climate sequences within the C-AST cycle with respect to the Florida USA climate are estimated for selected degradation mechanisms. It is found that for degradation of the outer backsheet polymer layer, the acceleration factor of the tropical climate sequence (the longest of the climate sequences) is f (T, G) = 17.3 with ultraviolet photodegradation; for polyethylene terephthalate hydrolysis (backsheets), f (T, RH) = 426; for electrochemical corrosion (PV cell), f (I) = 14.1; and for PbSn solder fatigue f (Delta T, r (T)) = 17.3. Here, T is the module temperature, G is the broadband spectrum irradiance on the plane of array of the module, RH is the relative humidity on the module surface, I is the leakage current through the module packaging, and r(T), the number of temperature reversals. The methods discussed herein are generally applicable for evaluating acceleration factors in other accelerated test methods.
引用
收藏
页数:8
相关论文
共 54 条
  • [1] [Anonymous], 2022, CUSTOM MARKET INSIGH
  • [2] [Anonymous], 2021, TECHNICAL SPECIFICAT
  • [3] [Anonymous], 2021, 6121522021 IEC
  • [4] [Anonymous], 2005, 61215 IEC
  • [5] [Anonymous], 2015, 628041 IEC
  • [6] [Anonymous], 2021, IEC IS 61215-2:2021 terrestrial photovoltaic (PV) modules-design qualification and type approval-part 2: test procedures
  • [7] [Anonymous], 2020, 632792020 TR IEC
  • [8] Measurement and simulation of vibrations of PV-modules induced by dynamic mechanical loads
    Assmus, Marcus
    Jack, Steffen
    Weiss, Karl-Anders
    Koehl, Michael
    [J]. PROGRESS IN PHOTOVOLTAICS, 2011, 19 (06): : 688 - 694
  • [9] PID: From material properties to outdoor performance & quality control counter measures
    Berghold, J.
    Koch, S.
    Pingel, S.
    Janke, S.
    Ukar, A.
    Grunow, P.
    Shioda, T.
    [J]. RELIABILITY OF PHOTOVOLTAIC CELLS, MODULES, COMPONENTS, AND SYSTEMS VIII, 2015, 9563
  • [10] Climate specific thermomechanical fatigue of flat plate photovoltaic module solder joints
    Bosco, Nick
    Silverman, Timothy J.
    Kurtz, Sarah
    [J]. MICROELECTRONICS RELIABILITY, 2016, 62 : 124 - 129