Comparison of corneal measurements in normal and keratoconus eyes using Anterior Segment Optical Coherence Tomography (AS-OCT) and Pentacam HR topographer

被引:1
|
作者
Said, Omar M. [1 ]
Kamal, Mahmoud [1 ]
Tawfik, Sara [1 ]
Saif, Ahmed Tamer Sayed [1 ]
机构
[1] Fayoum Univ, Fac Med, Dept Ophthalmol, Al Fayyum, Egypt
关键词
Topographic Corneal Thickness; Keratoconus; Pentacam; AS-OCT; EPITHELIAL THICKNESS; SCHEIMPFLUG CAMERA; REPEATABILITY; PACHYMETRY;
D O I
10.1186/s12886-023-02946-w
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundKeratoconus (KC) is easily recognized by its unique topographic pattern, but it can be difficult to distinguish subclinical form of the disease from the normal cornea. Optovue anterior segment optical coherence tomography (AS-OCT) helps diagnose KC.Aim of the workTo assess and the level of agreement of Keratometry-readings (K), Central Corneal Thickness (CCT) and Thinnest Corneal Thickness (TCT) measurements obtained by Optovue AS-OCT and Wavelight Oculyzer Pentacam HR in two groups: KC eyes and normal eyes.Patients and methodsThis is a prospective clinical observational study. The study included 110 eyes divided into two groups. The study group included 62 eyes with topographic evidence of KC. The control group included 48 eyes of normal subjects with no topographic evidence of KC. All of the participants underwent full cycloplegic refraction, spectacle best-corrected distance visual acuity, comprehensive slit-lamp biomicroscopy and fundoscopy. All participants underwent corneal topography by Pentacam HR and AS-OCT.ResultsThere were highly significant differences between the studied groups as regarding BCVA, intraocular pressure and CCT measurements which were found to be lower among KC group compared to the control one. There were highly significant differences between the studied groups regarding TCT measurement detected by Pentacam HR and AS-OCT which was found to be lower among the keratoconus group compared to the control one (470.9, 455.7 versus 541.9 and 518.7 respectively).ConclusionBoth Scheimpflug-based imaging and AS-OCT provide comparable readings with a good agreement regarding corneal pachymetry in keratoconus group with accurate identification of KC eyes and healthy ones. However, there was a significant difference in K readings between both devices in Keratoconus and control group.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Anterior Segment Optical Coherence Tomography (AS-OCT) Guided Reversal of Edematous Punctal Occlusion
    Elshorbagy, Mohammed Sameh
    Shalaby, Osama E.
    Eldesouky, Mohamed Ashraf
    Awara, Amr M.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1467 - 1472
  • [22] Corneal Epithelial Mapping Characteristics in Normal Eyes Using Anterior Segment Spectral Domain Optical Coherence Tomography
    Abusamak, Mohammad
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (03):
  • [23] Anterior segment optical coherence tomography to monitor corneal hydrops in pediatric keratoconus
    Ouederni, M.
    Ayedi, O.
    Khalifa, M. Ben Hadj
    Nefaa, F.
    Brour, J.
    Cheour, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (07): : 814 - 815
  • [24] Localization of Intraocular Lens Position in Anterior Segment Optical Coherence Tomography(AS-OCT) Using Deep Learning
    Moriguchi, Takaaki
    Tabuchi, Hitoshi
    Tanabe, Mao
    Deguchi, Hodaka
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [25] Comparison of Scheimpflug Corneal Tomography and Anterior Segment Optical Coherence Tomography Measurements in Corneal Cystinosis: A Case Series
    Vercauteren, Leonie
    Consejo, Alejandra
    De Vries, Meindert Jan
    Krolo, Iva
    Koppen, Carina
    Dhubhghaill, Sorcha Ni
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (07): : 321 - 328
  • [26] Anterior segment optical coherence tomography (AS-OCT) image analysis methods and applications: A systematic review
    Marin, Yoel F. Garcia
    Alonso-Caneiro, David
    Vincent, Stephen J.
    Collins, Michael J.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 146
  • [27] Full-Thickness Corneal Suture Analysis Using Anterior Segment Ocular Coherence Tomography (AS-OCT) in Traumatic Wounds
    Sara M. Pérez
    Valentina Cárdenas Arias
    Margarita María Perilla Pino
    Camilo Eduardo Martínez Sánchez
    SN Comprehensive Clinical Medicine, 5 (1)
  • [28] Comparison of corneal topographic indices of keratoconus versus normal eyes by using pentacam imaging
    Yekta, A. A.
    Khabazkhoob, M.
    Hashemi, H.
    Bakhshi, S.
    Ostadimoghaddam, H.
    Heravian, J.
    Rezvan, F.
    Yekta, R.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [29] The role of anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) in conjunctival nevi
    Lauwers, N.
    Janssens, K.
    Mertens, M.
    De Keizer, R. J. W.
    De Groot, V.
    ACTA OPHTHALMOLOGICA, 2016, 94
  • [30] THE ACCURACY OF ANTERIOR SEGMENT OPTICAL COHERENCE TOMOGRAPHY (AS-OCT) IN LOCALIZING EXTRAOCULAR RECTUS MUSCLES INSERTIONS
    Paciuc-Beja, Miguel
    Salcedo-Villanueva, Guillermo
    Quiroz-Mercado, Hugo
    JOURNAL OF AAPOS, 2015, 19 (05): : 489 - 490