BackgroundKeratoconus (KC) is easily recognized by its unique topographic pattern, but it can be difficult to distinguish subclinical form of the disease from the normal cornea. Optovue anterior segment optical coherence tomography (AS-OCT) helps diagnose KC.Aim of the workTo assess and the level of agreement of Keratometry-readings (K), Central Corneal Thickness (CCT) and Thinnest Corneal Thickness (TCT) measurements obtained by Optovue AS-OCT and Wavelight Oculyzer Pentacam HR in two groups: KC eyes and normal eyes.Patients and methodsThis is a prospective clinical observational study. The study included 110 eyes divided into two groups. The study group included 62 eyes with topographic evidence of KC. The control group included 48 eyes of normal subjects with no topographic evidence of KC. All of the participants underwent full cycloplegic refraction, spectacle best-corrected distance visual acuity, comprehensive slit-lamp biomicroscopy and fundoscopy. All participants underwent corneal topography by Pentacam HR and AS-OCT.ResultsThere were highly significant differences between the studied groups as regarding BCVA, intraocular pressure and CCT measurements which were found to be lower among KC group compared to the control one. There were highly significant differences between the studied groups regarding TCT measurement detected by Pentacam HR and AS-OCT which was found to be lower among the keratoconus group compared to the control one (470.9, 455.7 versus 541.9 and 518.7 respectively).ConclusionBoth Scheimpflug-based imaging and AS-OCT provide comparable readings with a good agreement regarding corneal pachymetry in keratoconus group with accurate identification of KC eyes and healthy ones. However, there was a significant difference in K readings between both devices in Keratoconus and control group.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Comparison of corneal measurements in normal and keratoconus eyes using Anterior Segment Optical Coherence Tomography (AS-OCT) and Pentacam HR topographer
    Omar M. Said
    Mahmoud Kamal
    Sara Tawfik
    Ahmed Tamer Sayed Saif
    BMC Ophthalmology, 23
  • [2] Anterior segment optical coherence tomography (AS-OCT) for the assessment of corneal alkali injury
    Lin, Jonathan
    Luisi, Jonathan
    Kraft, Edward R.
    Giannos, Steven
    Schmitz-Brown, Mary
    Motamedi, Massoud
    Gupta, Praveena
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [3] Repeatability and Comparison of Corneal Tomography in Mild to Severe Keratoconus Between the Anterior Segment OCT MS-39 and Pentacam HR
    Seiler, Theo G.
    Mueller, Maya
    Baiao, Tiago Mendes
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (04) : 250 - +
  • [4] Anterior Segment Optical Coherence Tomography (AS-OCT) Visualization of Anterior Vitritis
    Zicarelli, Federico
    Staurenghi, Giovanni
    Invernizzi, Alessandro
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2023, 31 (05) : 1101 - 1102
  • [5] Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus
    Schiano-Lomoriello, Domenico
    Bono, Valeria
    Abicca, Irene
    Savini, Giacomo
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [6] Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus
    Domenico Schiano-Lomoriello
    Valeria Bono
    Irene Abicca
    Giacomo Savini
    Scientific Reports, 10
  • [7] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Ghoreishi, Seyed Mohammad
    Mortazavi, Seyed Ali Akbar
    Abtahi, Zahra-Alsadat
    Abtahi, Mohammad-Ali
    Sonbolestan, Seyed Ali
    Abtahi, Seyed-Hossein
    Mohammadinia, Mohadeseh
    Isfahani, Kimia Nekouie
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (04) : 965 - 971
  • [8] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Seyed Mohammad Ghoreishi
    Seyed Ali Akbar Mortazavi
    Zahra-Alsadat Abtahi
    Mohammad-Ali Abtahi
    Seyed Ali Sonbolestan
    Seyed-Hossein Abtahi
    Mohadeseh Mohammadinia
    Kimia Nekouie Isfahani
    International Ophthalmology, 2017, 37 : 965 - 971
  • [9] Anterior segment optical coherence tomography (AS-OCT) in strabismus following trauma
    Kaur, Savleen
    Bradfield, Yasmin
    Vyshak, A. S.
    Gupta, Kajree
    Gupta, Pankaj
    Sukhija, Jaspreet
    JOURNAL OF AAPOS, 2024, 28 (04):
  • [10] Repeatability of topographic corneal thickness in keratoconus comparing Visante™ OCT and Oculus Pentacam HR® topographer
    Otchere, Heinz
    Sorbara, Luigina
    CONTACT LENS & ANTERIOR EYE, 2017, 40 (04): : 217 - 223