Colorimetric detection of mercury (Hg2+) using UV-vis spectroscopy and digital image analysis based on gold nanoparticles functionalized with bromelain enzyme

被引:6
|
作者
Suhaidi, Nurul Azreen [1 ]
Halmi, Mohd Izuan Effendi [1 ,6 ]
Rashidi, Asraf Alif [1 ]
Anuar, Mohd Firdaus Mohd [1 ]
Mahmud, Khairil [2 ,6 ]
Kusnin, Norzila [3 ]
Abd Gani, Siti Salwa [4 ]
Abd Shukor, Mohd Yunus [5 ]
机构
[1] Univ Putra Malaysia, Fac Agr, Dept Land Management, Serdang 43400, Selangor, Malaysia
[2] Univ Putra Malaysia UPM, Fac Agr, Dept Crop Sci, Serdang 43400, Selangor, Malaysia
[3] Univ Putra Malaysia, Inst Nanosci & Nanotechnol, Serdang 43400, Selangor, Malaysia
[4] Univ Putra Malaysia, Fac Agr, Dept Agr Technol, Serdang 43400, Selangor, Malaysia
[5] Univ Putra Malaysia, Fac Biotechnol & Biomol Sci, Dept Biochem, Serdang 43400, Selangor, Malaysia
[6] Univ Putra Malaysia, Inst Biosci, Unit Biodivers, Serdang 43400, Selangor, Malaysia
关键词
Mercury; Gold nanoparticles; Bromelain; Colorimetric detection; Response surface methodology; SURFACE METHODOLOGY RSM; HEAVY-METALS; OPTIMIZATION; SMARTPHONE; DESIGN; PAPER; WATER; ASSAY; LEAD; BLUE;
D O I
10.1007/s13205-023-03532-z
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A very sensitive and selective colorimetric biosensor for the measurement of mercury ion (Hg2+) in environmental samples has been developed using functionalized gold nanoparticles with bromelain enzyme (brn-AuNPs). This work has shown that Hg2+ measurement based on spectrophotometer and digital image analysis is a very innovative and successful method for providing an effective preliminary system and has promise for the future of water quality biomonitoring. Response Surface Methodology (RSM), a Box-Behnken design-based technique, was used to identify the optimum levels of functionalization of bromelain to AuNPs. The created model's validity was confirmed, and statistical analysis revealed that the ideal functionalize conditions were 1 mM of AuNPs, functionalize with 0.59 mM bromelain concentration on 14 celcius temperature and 72 h incubation time. The lowest colorimetric detection concentration (LOD) of brn-AuNPs of Hg2+ was 0.0092 ppm and 0.011 ppm for spectrophotometer and digital image analysis. As shown, digital image analysis had advantages based on the LOD result comparable to UV-VIS spectrophotometer. The practical application of the brn-AuNPs sensing was proven with mercury determination in water samples. The present study developed a robust sensor, which successfully implemented in a compact portable sensor kit, turning this sensor into a very potent tool for the development water quality biomonitoring system of Hg2+ application.
引用
收藏
页数:17
相关论文
共 34 条
  • [31] Improved detection of Hg2+ in aqueous solution with high sensitivity and selectivity by using mercury-specific DNA, Sybr Green I and gold nanoparticles
    Xu, Hui
    Gao, Shuli
    Chen, Jiannong
    Liu, Quanwen
    ADVANCED MATERIALS, PTS 1-4, 2011, 239-242 : 934 - +
  • [32] Reliable and reproducible colorimetric detection of mercury ions (Hg2+) using green synthesized optically active silver nanoparticles containing thin film on flexible plastic substrate
    Lokhande, A. C.
    Shinde, N. M.
    Shelke, A.
    Babar, P. T.
    Kim, Jin Hyeok
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2017, 21 (09) : 2747 - 2751
  • [33] Reliable and reproducible colorimetric detection of mercury ions (Hg2+) using green synthesized optically active silver nanoparticles containing thin film on flexible plastic substrate
    A. C. Lokhande
    N. M. Shinde
    A. Shelke
    P. T. Babar
    Jin Hyeok Kim
    Journal of Solid State Electrochemistry, 2017, 21 : 2747 - 2751
  • [34] A novel colorimetric sensor for naked-eye detection of cysteine and Hg2+ based on "on-off" strategy using Co/Zn-grafted mesoporous silica nanoparticles
    Aghayan, Morvarid
    Mahmoudi, Ali
    Sazegar, Mohammad Reza
    Adhami, Forogh
    DALTON TRANSACTIONS, 2021, 50 (38) : 13345 - 13356