Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

被引:5
|
作者
Nelson, Nicholas P. [1 ]
Culberson, Wesley S. [1 ]
Hyer, Daniel E. [2 ]
Geoghegan, Theodore J. [2 ]
Patwardhan, Kaustubh A. [2 ]
Smith, Blake R. [2 ]
Flynn, Ryan T. [2 ]
Yu, Jen [3 ]
Gutierrez, Alonso N. [3 ]
Hill, Patrick M. [4 ]
机构
[1] Univ Wisconsin Madison, Sch Med & Publ Hlth, Dept Med Phys, 1111 Highland Ave, Madison, WI 53705 USA
[2] Univ Iowa Hosp & Clin, Dept Radiat Oncol, 200 Hawkins Dr, Iowa City, IA 52242 USA
[3] Baptist Hlth South Florida, Miami Canc Inst, Dept Radiat Oncol, 8900 N Kendall Dr, Miami, FL 33176 USA
[4] Univ Wisconsin Madison, Sch Med & Publ Hlth, Dept Human Oncol, 600 Highland Ave, Madison, WI 53792 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
proton therapy; collimation; Monte Carlo; dosimetry; IONIZATION-CHAMBER ARRAY; BRAIN-TUMORS; SPOT SIZE; QUALITY; SYSTEM; IMPACT;
D O I
10.1088/1361-6560/acb6cd
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 x 3 x 3 cm(3) target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic (TM) EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Clinical Outcome of Sacral Chordoma Patients Treated with Pencil Beam Scanning Proton Therapy
    Walser, M.
    Bojaxhiu, B.
    Kawashiro, S.
    Tran, S.
    Beer, J.
    Leiser, D.
    Pica, A.
    Bachtiary, B.
    Weber, D. C.
    CLINICAL ONCOLOGY, 2021, 33 (12) : E578 - E585
  • [42] Effects of spot size errors in DynamicARC pencil beam scanning proton therapy planning
    Rana, Suresh
    Rosenfeld, Anatoly B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (23)
  • [43] Detectors for quality assurance of pencil beam scanning gantries for proton therapy
    Gagnon-Moisan, F.
    van der Meer, R.
    Chowdhuri, Z.
    Eichin, M.
    Koenig, S.
    Schmid, F. -J.
    Weber, D. C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S44 - S45
  • [44] An adaptive spot placement method on Cartesian grid for pencil beam scanning proton therapy
    Lin, Bowen
    Fu, Shujun
    Lin, Yuting
    Rotondo, Ronny L.
    Huang, Weizhang
    Li, Harold H.
    Chen, Ronald C.
    Gao, Hao
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (23)
  • [45] Evaluation of the ray-casting analytical algorithm for pencil beam scanning proton therapy
    Winterhalter, Carla
    Zepter, Stefan
    Shim, Sojin
    Meier, Gabriel
    Bolsi, Alessandra
    Fredh, Anna
    Hrbacek, Jan
    Oxley, David
    Zhang, Ye
    Weber, Damien C.
    Lomax, Antony
    Safai, Sairos
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06)
  • [46] A pre-absorber optimization technique for pencil beam scanning proton therapy treatments
    Fracchiolla, Francesco
    Fellin, Francesco
    Innocenzi, Marta
    Lipparini, Mirko
    Lorentini, Stefano
    Widesott, Lamberto
    Farace, Paolo
    Schwarz, Marco
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 145 - 152
  • [47] Pencil-beam scanning proton therapy for low-grade glioma patients
    Willmann, Jonas
    Leiser, Dominic
    Weber, Damien Charles
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S822 - S825
  • [48] Dose perturbations in proton pencil beam delivery investigated by dynamically deforming silicone-based radiochromic dosimeters
    Jensen, Simon, V
    Muren, Ludvig P.
    Balling, Peter
    Petersen, Jorgen B. B.
    Valdetaro, Lia B.
    Poulsen, Per R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (23)
  • [49] Dosimetric Impact of In-Air Spot Size Variations for Commissioning a Room-Matched Beam Model for Pencil Beam Scanning Proton Therapy
    Zhang, Y.
    Giebeler, A.
    Mascia, A.
    Piskulich, F.
    Perles, L.
    Lepage, R.
    Dong, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 112 - +
  • [50] Synchrotron-Based Pencil Beam Scanning Nozzle with an Integrated Mini-Ridge Filter: A Dosimetric Study to Optimize Treatment Delivery
    Wang, Xianliang
    Li, Yupeng
    Zhang, Xiaodong
    Li, Heng
    Miyazaki, Koichi
    Fujimoto, Rintaro
    Akiyama, Hiroshi
    Gillin, Michael T.
    Poenisch, Falk
    Sahoo, Narayan
    Grosshans, David
    Gunn, Brandon
    Frank, Steven Jay
    Wang, Pei
    Lang, Jinyi
    Hou, Qing
    Zhu, Xiaorong Ronald
    CANCERS, 2017, 9 (12):