Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

被引:5
|
作者
Nelson, Nicholas P. [1 ]
Culberson, Wesley S. [1 ]
Hyer, Daniel E. [2 ]
Geoghegan, Theodore J. [2 ]
Patwardhan, Kaustubh A. [2 ]
Smith, Blake R. [2 ]
Flynn, Ryan T. [2 ]
Yu, Jen [3 ]
Gutierrez, Alonso N. [3 ]
Hill, Patrick M. [4 ]
机构
[1] Univ Wisconsin Madison, Sch Med & Publ Hlth, Dept Med Phys, 1111 Highland Ave, Madison, WI 53705 USA
[2] Univ Iowa Hosp & Clin, Dept Radiat Oncol, 200 Hawkins Dr, Iowa City, IA 52242 USA
[3] Baptist Hlth South Florida, Miami Canc Inst, Dept Radiat Oncol, 8900 N Kendall Dr, Miami, FL 33176 USA
[4] Univ Wisconsin Madison, Sch Med & Publ Hlth, Dept Human Oncol, 600 Highland Ave, Madison, WI 53792 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 05期
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
proton therapy; collimation; Monte Carlo; dosimetry; IONIZATION-CHAMBER ARRAY; BRAIN-TUMORS; SPOT SIZE; QUALITY; SYSTEM; IMPACT;
D O I
10.1088/1361-6560/acb6cd
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 x 3 x 3 cm(3) target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic (TM) EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Technical note: Delivery benefit and dosimetric implication of synchrotron-based proton pencil beam scanning using continuous scanning mode
    Liang, Xiaoying
    Beltran, Chris J.
    Liu, Chunbo
    Shen, Jiajian
    Li, Heng
    Furutani, Keith M.
    MEDICAL PHYSICS, 2023, 50 (08) : 5252 - 5261
  • [32] Dosimetric Impact of intra- and inter-fraction motion in liver pencil beam scanning proton therapy
    Nankali, Saber
    Worm, Esben Schjodt
    Thomsen, Jakob Borup
    Stick, Line Bjerregaard
    Hoyer, Morten
    Weber, Britta
    Mortensen, Hanna Rahbek
    Poulsen, Per Rugaard
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4193 - S4196
  • [33] Pencil beam scanning proton therapy for pediatric intracranial ependymoma
    Ares, Carmen
    Albertini, Francesca
    Frei-Welte, Martina
    Bolsi, Alessandra
    Grotzer, Michael A.
    Goitein, Gudrun
    Weber, Damien C.
    JOURNAL OF NEURO-ONCOLOGY, 2016, 128 (01) : 137 - 145
  • [34] Validation and application of a fast Monte Carlo algorithm for assessing the clinical impact of approximations in analytical dose calculations for pencil beam scanning proton therapy
    Huang, Sheng
    Souris, Kevin
    Li, Siyang
    Kang, Minglei
    Montero, Ana Maria Barragan
    Janssens, Guillaume
    Lin, Alexander
    Garver, Elizabeth
    Ainsley, Christopher
    Taylor, Paige
    Xiao, Ying
    Lin, Liyong
    MEDICAL PHYSICS, 2018, 45 (12) : 5631 - 5642
  • [35] Dosimetric analysis of local failures in skull-base chordoma and chondrosarcoma following pencil beam scanning proton therapy
    Basler, Lucas
    Poel, Robert
    Schroeder, Christina
    Bolsi, Alessandra
    Lomax, Antony
    Tanadini-Lang, Stephanie
    Guckenberger, Matthias
    Weber, Damien C.
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [36] Dosimetric Correlation of Acute Radiation Dermatitis in Patients With Breast Cancer Undergoing Hypofractionated Proton Beam Therapy Using Pencil Beam Scanning
    Huang, Eng-Yen
    Ho, Meng Wei
    Wang, Yu-Ming
    JOURNAL OF BREAST CANCER, 2024, 27 (03) : 187 - 200
  • [37] Experimental validation of a 4D dose calculation routine for pencil beam scanning proton therapy
    Pfeiler, Tina
    Baeumer, Christian
    Engwall, Erik
    Geismar, Dirk
    Spaan, Bernhard
    Timmermann, Beate
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (02): : 121 - 133
  • [38] Dosimetric analysis of local failures in skull-base chordoma and chondrosarcoma following pencil beam scanning proton therapy
    Lucas Basler
    Robert Poel
    Christina Schröder
    Alessandra Bolsi
    Antony Lomax
    Stephanie Tanadini-Lang
    Matthias Guckenberger
    Damien C. Weber
    Radiation Oncology, 15
  • [39] Proton FLASH: passive scattering or pencil beam scanning?
    Zhang, Guoliang
    Wang, Junliang
    Wang, Yuenan
    Peng, Hao
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03):
  • [40] A method to select aperture margin in collimated spot scanning proton therapy
    Wang, Dongxu
    Smith, Blake R.
    Gelover, Edgar
    Flynn, Ryan T.
    Hyer, Daniel E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (07): : N109 - N119