Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

被引:5
|
作者
Nelson, Nicholas P. [1 ]
Culberson, Wesley S. [1 ]
Hyer, Daniel E. [2 ]
Geoghegan, Theodore J. [2 ]
Patwardhan, Kaustubh A. [2 ]
Smith, Blake R. [2 ]
Flynn, Ryan T. [2 ]
Yu, Jen [3 ]
Gutierrez, Alonso N. [3 ]
Hill, Patrick M. [4 ]
机构
[1] Univ Wisconsin Madison, Sch Med & Publ Hlth, Dept Med Phys, 1111 Highland Ave, Madison, WI 53705 USA
[2] Univ Iowa Hosp & Clin, Dept Radiat Oncol, 200 Hawkins Dr, Iowa City, IA 52242 USA
[3] Baptist Hlth South Florida, Miami Canc Inst, Dept Radiat Oncol, 8900 N Kendall Dr, Miami, FL 33176 USA
[4] Univ Wisconsin Madison, Sch Med & Publ Hlth, Dept Human Oncol, 600 Highland Ave, Madison, WI 53792 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 05期
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
proton therapy; collimation; Monte Carlo; dosimetry; IONIZATION-CHAMBER ARRAY; BRAIN-TUMORS; SPOT SIZE; QUALITY; SYSTEM; IMPACT;
D O I
10.1088/1361-6560/acb6cd
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 x 3 x 3 cm(3) target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic (TM) EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Development and validation of an optimal GATE model for proton pencil-beam scanning delivery
    Asadi, Ali
    Akhavanallaf, Azadeh
    Hosseini, Seyed Abolfazl
    Vosoughi, Naser
    Zaidi, Habib
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (04): : 591 - 600
  • [22] The dosimetric enhancement of GRID profiles using an external collimator in pencil beam scanning proton therapy
    Smith, Blake R.
    Nelson, Nicholas P.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Hill, Patrick M.
    Yu, Jen
    Gutierrez, Alonso N.
    Allen, Bryan G.
    Hyer, Daniel E.
    MEDICAL PHYSICS, 2022, 49 (04) : 2684 - 2698
  • [23] Dosimetric Comparison of Patient Alignment Techniques in Pencil Beam Scanning Proton Therapy for Prostate Cancer
    Remick, J.
    Snider, J. W., III
    Diwanji, T.
    Houser, T.
    Langner, U.
    Zhu, M.
    Bentzen, S. M.
    Feigenberg, S. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E714 - E714
  • [24] Dosimetric response of radiophotoluminescent glass detectors in a scanning pencil proton beam
    Pasaricek, Luka
    Knezevic, Zeljka
    Brkic, Hrvoje
    Davidkova, Marie
    Navratil, Matej
    Vondracek, Vladimir
    Majer, Marija
    RADIATION MEASUREMENTS, 2024, 176
  • [25] Dosimetric uncertainties in pencil beam proton therapy for breast cancer
    Tommasino, F.
    Lorentini, S.
    Schwarz, M.
    Fellin, F.
    Farace, P.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S68 - S68
  • [26] Dynamically Collimated Proton Arc Therapy
    Smith, B.
    Flynn, R.
    Hyer, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E211 - E211
  • [27] Pencil Beam Scanning:: a dynamical approach to proton therapy
    Sepulchre, R
    Gérard, M
    Marchand, B
    Prieels, D
    Bauvir, B
    IEEE INTERNATIONAL SYMPOSIUM ON BIO-INFORMATICS AND BIOMEDICAL ENGINEERING, PROCEEDINGS, 2000, : 370 - 375
  • [28] Factors Predicting Dosimetric Consequence of Gastrointestinal Density in Pencil Beam Scanning Proton Therapy for Abdominal Neuroblastoma
    Lim, P. S.
    Rompokos, V.
    Bizzocchi, N.
    Gillies, C.
    Gosling, A.
    Royle, G.
    Chang, Y. -C.
    Gains, J.
    Gaze, M.
    PEDIATRIC BLOOD & CANCER, 2020, 67 : S73 - S74
  • [29] Theoretical Benefits of Dynamic Collimation in Pencil Beam Scanning Proton Therapy for Brain Tumors: Dosimetric and Radiobiological
    Moignier, Alexandra
    Gelover, Edgar
    Wang, Dongxu
    Smith, Blake
    Flynn, Ryan
    Kirk, Maura
    Lin, Liyong
    Solberg, Timothy
    Lin, Alexander
    Hyer, Daniel
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 171 - 180
  • [30] A CASE STUDY IN PROTON PENCIL-BEAM SCANNING DELIVERY
    Kooy, Hanne M.
    Clasie, Benjamin M.
    Lu, Hsiao-Ming
    Madden, Thomas M.
    Bentefour, Hassan
    Depauw, Nicolas
    Adams, Judy A.
    Trofimov, Alexei V.
    Demaret, Denis
    Delaney, Thomas F.
    Flanz, Jacob B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (02): : 624 - 630