Effect of Arthrodesis Device Type and Trajectory on Subtalar Joint Compression

被引:0
|
作者
Beals, Caitlyn J. [1 ]
Dupont, Kenneth M. [2 ]
Gross, Christopher E. [3 ]
Safranski, David L. [2 ,4 ,5 ]
机构
[1] Georgia Inst Technol, WH Coulter Dept Biomed Engn, Atlanta, GA USA
[2] Enovis Foot & Ankle, Clin Affairs, Atlanta, GA USA
[3] Med Univ South Carolina, Dept Orthopaed Surg, Foot & Ankle Div, Charleston, SC USA
[4] Georgia Inst Technol, Sch Mat Sci & Engn, Atlanta, GA USA
[5] Enovis Foot & Ankle, Clin Affairs, 1575 Northside Dr NW,Suite 440, Atlanta, GA 30318 USA
关键词
biomechanics; nitinol; subtalar arthrodesis; sustained dynamic compression; FIXATION; FUSION;
D O I
10.1053/j.jfas.2023.04.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The use of subtalar arthrodesis procedures has been widely implemented to relieve hindfoot issues after failure of conservative treatments; however, fusion failures persist in some patients with certain risk factors. Currently, surgeons utilize cannulated screws in these arthrodesis procedures to immobilize the subtalar joint. Recent clinical studies have demonstrated improved fusion outcomes in at-risk patients using sustained dynamic compression devices in the tibiotalocalcaneal complex. These devices utilize pseudoelastic nitinol which enables sustained dynamic compression when faced with postoperative bone resorption, joint settling, and bone relaxation. While the clinical success of these devices has been established in the tibiotalocalcaneal complex, the ability of sustained dynamic compression devices to apply joint compression in the subtalar joint has not been quantified. As such, the goals of this study were to (1) compare the ability of static compression devices and sustained dynamic compression devices to apply joint compression and (2) assess the impact of device trajectory on joint compression. A custom mechanical testing fixture was utilized to test the compression applied across the subtalar joint by one sustained dynamic compression device (in anterior and posterior trajectories) as compared to 2 cannulated screws (in both parallel and diverging trajectories). Testing revealed the sustained dynamic compression devices generated 53% greater compression as compared to the static compression devices, despite single versus dual device usage, respectively. Additionally, both types of devices applied joint compression forces in an insertion trajectory-independent manner. These data illustrate the ability of a single SDC device to maintain significantly improved joint compressive forces as compared to 2 static cannulated screws, regardless of insertion trajectory. These SDC devices may be of particular interest for at-risk patients or in revision cases. (c) 2023 The Author(s). This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)
引用
收藏
页码:812 / 815
页数:4
相关论文
共 50 条
  • [31] Compensatory Motion of the Subtalar Joint Following Tibiotalar Arthrodesis: An in Vivo Dual-Fluoroscopy Imaging Study
    Lenz, Amy L.
    Nichols, Jennifer A.
    Roach, Koren E.
    Foreman, K. Bo
    Barg, Alexej
    Saltzman, Charles L.
    Anderson, Andrew E.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2020, 102 (07) : 600 - 608
  • [32] Proximal Interphalangeal Joint Arthrodesis of the Hand Utilising a Rigid Intramedullary Device
    Taylor, Fraser
    Johns, Nicholas
    Manohoran, Varuguna
    Graham, David
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2023, 28 (02) : 297 - 300
  • [33] CONTACT CHARACTERISTICS OF THE SUBTALAR JOINT - THE EFFECT OF TALAR NECK MISALIGNMENT
    SANGEORZAN, BJ
    WAGNER, UA
    HARRINGTON, RM
    TENCER, AF
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (04) : 544 - 551
  • [34] Evaluation of Midterm Results of the Panta Nail: An Active Compression Tibiotalocalcaneal Arthrodesis Device
    Griffin, Matthew J.
    Coughlin, Michael J.
    JOURNAL OF FOOT & ANKLE SURGERY, 2018, 57 (01) : 74 - 80
  • [35] Distal interphalangeal joint arthrodesis with a headless compression screw: morphometric and functional analyses
    Song, Joo-Hyoun
    Lee, Joo-Yup
    Chung, Yang-Guk
    Park, Il-Jung
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (05) : 663 - 669
  • [36] Advantages of a compression screw for the arthrodesis of the first metatarsophalangeal joint of the foot : comparative study
    Neri, Thomas
    Beach, Aaron Beach
    Farizon, Frederic
    Philippot, Remi
    ACTA ORTHOPAEDICA BELGICA, 2020, 86 (S 2): : 144 - 151
  • [37] Three-Plane Calcaneal Osteotomy With Joint Preservation vs Subtalar Arthrodesis to Treat Painful Calcaneal Fracture Malunions
    Feng, Hui
    Ji, Dong-Dong
    Yang, Xin-Quan
    Yue, Yang
    Wang, Zhe
    Zhang, Yan
    Liu, Pei-Long
    Liang, Jing-Qi
    Zhao, Hong-Mou
    FOOT & ANKLE INTERNATIONAL, 2025, 46 (03) : 295 - 302
  • [38] Effect of Pathology on Union of First Metatarsophalangeal Joint Arthrodesis
    Korim, Muhammad Tawfiq
    Allen, Patricia E.
    FOOT & ANKLE INTERNATIONAL, 2015, 36 (01) : 51 - 54
  • [39] Torsional stiffness after subtalar arthrodesis using second generation headless compression screws: Biomechanical comparison of 2-screw and 3-screw fixation
    Riedl, Markus
    Glisson, Richard R.
    Matsumoto, Takumi
    Hofstaetter, Stefan G.
    Easley, Mark E.
    CLINICAL BIOMECHANICS, 2017, 45 : 32 - 37
  • [40] Arthrodesis of proximal inter-phalangeal joint for hammertoe: intramedullary device options
    Guelfi M.
    Pantalone A.
    Daniel J.C.
    Vanni D.
    Guelfi M.G.B.
    Salini V.
    Journal of Orthopaedics and Traumatology, 2015, 16 (4) : 269 - 273