Homogeneous immunoassay utilizing fluorescence resonance energy transfer from quantum dots to tyramide dyes deposited on full immunocomplexes

被引:0
|
作者
Xu, Zihan [1 ]
Liu, Xiaojun [1 ]
Zong, Chenghua [1 ]
Zhang, Qingquan [1 ]
Gai, Hongwei [1 ]
机构
[1] Jiangsu Normal Univ, Sch Chem & Mat Sci, Shanghai Rd 101, Xuzhou, Jiangsu, Peoples R China
关键词
PROXIMITY HYBRIDIZATION;
D O I
10.1039/d3an01174g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is an urgent need for homogeneous immunoassays that offer sufficient sensitivity for routine clinical practice. In this study, we have developed a highly sensitive, fluorescence resonance energy transfer (FRET)-based homogeneous immunoassay. Unlike previous FRET-based homogeneous immunoassays, where acceptors were attached to antibody molecules located far from the donor, we employed acceptors to label the entire sandwich-structured immunocomplex, including two antibodies and one antigen. As a result, the FRET signal was amplified by a factor of 10, owing to the reduced distance between the donor and acceptors. We validated our method by quantifying carcinoembryonic antigen (CEA) and & alpha;-fetoprotein (AFP) in PBS buffer and blank plasma. The limits of detection (LOD) for CEA and AFP in both PBS buffer and blank plasma were comparable, reaching sub-femtomolar levels. Furthermore, we successfully quantified CEA and AFP in three human plasma samples, thereby confirming the reliability of our method for clinical applications. By depositing Tyramide dyes on a QD labelled full immunocomplex, FRET between QDs and activated dyes occurs and a wash free, high sensitivity immunoassay is developed.
引用
收藏
页码:4877 / 4884
页数:8
相关论文
共 50 条
  • [1] Fluorescence resonance energy transfer between two quantum dots with immunocomplexes of antigen and antibody as a bridge
    Li, Yabing
    Ma, Qiang
    Wang, Xinyan
    Su, Xingguang
    LUMINESCENCE, 2007, 22 (01) : 60 - 66
  • [2] HOMOGENEOUS FLUORESCENCE RESONANCE ENERGY TRANSFER IMMUNOASSAY FOR THE DETERMINATION OF ZEARALENONE
    Li, Taihua
    Kim, Bo Bae
    Shim, Won-Bo
    Byun, Ju-Young
    Chung, Duck-Hwa
    Shin, Yong-Beom
    Kim, Min-Gon
    ANALYTICAL LETTERS, 2014, 47 (03) : 453 - 464
  • [3] Upconversion fluorescence resonance energy transfer in a homogeneous immunoassay for estradiol
    Kuningas, K
    Ukonaho, T
    Päkkilä, H
    Rantanen, T
    Rosenberg, J
    Lövgren, T
    Soukka, T
    ANALYTICAL CHEMISTRY, 2006, 78 (13) : 4690 - 4696
  • [4] General Bioluminescence Resonance Energy Transfer Homogeneous Immunoassay for Small Molecules Based on Quantum Dots
    Yu, Xuezhi
    Wen, Kai
    Wang, Zhanhui
    Zhang, Xiya
    Li, Chenglong
    Zhang, Suxia
    Shen, Jianzhong
    ANALYTICAL CHEMISTRY, 2016, 88 (07) : 3512 - 3520
  • [5] Homogeneous FRET immunoassay based on lanthanides to quantum dots energy transfer
    Hildebrandt, Niko
    Charbonniere, Loic J.
    Ziessel, Raymond F.
    Loehmannsroeben, Hans-Gerd
    COLLOIDAL QUANTUM DOTS FOR BIOMEDICAL APPLICATIONS II, 2007, 6448
  • [6] Studies on fluorescence resonance energy transfer between dyes and water-soluble quantum dots
    Chen, QD
    Ma, QA
    Wan, Y
    Su, XG
    Lin, ZB
    Jin, QH
    LUMINESCENCE, 2005, 20 (4-5) : 251 - 255
  • [7] Studies on fluorescence resonance energy transfer between dyes and water-soluble quantum dots
    Wang, Xin-Yan
    Ma, Qiang
    Li, Ya-Bing
    Li, Bing
    Su, Xing-Guang
    Jin, Qin-Han
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2005, 50 (03): : 141 - 146
  • [8] Quantum dots as fluorescence resonance energy transfer donors in cells
    McGrath, Nicole
    Barroso, Margarida
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (03)
  • [9] Homogeneous noncompetitive immunoassay for 17ß-Estradiol based on fluorescence resonance energy transfer
    Kokko, Tiina
    Kokko, Leena
    Loevgren, Tirno
    Soukka, Tero
    ANALYTICAL CHEMISTRY, 2007, 79 (15) : 5935 - 5940
  • [10] Fluorescence immunoassay of octachlorostyrene based on Forster resonance energy transfer between CdTe quantum dots and rhodamine B
    Wang, Xin
    Sheng, Pengtao
    Zhou, Liping
    Tong, Xi
    Shi, Lei
    Cai, Qingyun
    BIOSENSORS & BIOELECTRONICS, 2014, 60 : 52 - 56