Experimental evaluation of flat slabs strengthened with post-installed shear bolts with pre-loading

被引:3
|
作者
Bolesova, Maria [1 ]
Gajdosova, Katarina [1 ]
机构
[1] Slovak Univ Technol Bratislava, Fac Civil Engn, Dept Concrete Struct & Bridges, Radlinskeho 11, Bratislava 81005, Slovakia
关键词
Flat slab; Strengthening; Punching; Bolts; Pre-loading; REINFORCED-CONCRETE SLABS; PUNCHING SHEAR; COLUMN CONNECTIONS; BEHAVIOR; CAPACITY; RETROFIT; TESTS;
D O I
10.1016/j.engstruct.2023.116659
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Based on the possibility of brittle failure of flat slabs, there are relevant requirements for their strengthening in cases of deficient design or increasing loads. One of the essential factors to consider is, that an existing structure requiring strengthening always has some history of loading. An experimental study was performed in order to verify the effect of strengthening with post-installed shear reinforcement on flat slabs with pre-loading. Four full-size square flat slabs with dimensions of 2500 x 2500 mm, strengthened with shear bolts, were tested, as well as a reference slab without any shear reinforcement. The shear reinforcement was installed before loading in two specimens. For this purpose, bolts consisting of threaded rods, nuts and washers were used. Two types of threaded rods were used, i.e. rods of a diameter of 12 mm and a steel grade of 8.8 and rods of a diameter of 10 mm with 4.8 steel grade, which predestined the failure mode of the flat slab. Two other specimens were loaded up to 50% and 75% of their initial shear resistance without shear reinforcement - obtained as the resistance of the reference slab. Subsequently, they were unloaded or loaded on 50% of their resistance and strengthened with shear bolts. The pre-loading of flat slabs before strengthening demonstrated a decreasing effect on the achieved resistance of flat slabs strengthened by post-installed shear reinforcement (resistance 1715 kN for slab without pre-loading, 1647 kN for slab pre-loaded to 50% of initial resistance, and 1563 kN for slab pre-loaded to 75% of initial resistance). The measured decrease in the resistance compared to the slab strengthened before loading was 5% to 10%, depending on the pre-loading level.
引用
收藏
页数:13
相关论文
共 19 条
  • [1] Experimental and numerical study into the punching shear strengthening of RC flat slabs using post-installed steel bolts
    Saleh, Haifa
    Kalfat, Robin
    Abdouka, Kamiran
    Al-Mahaidi, Riadh
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 188 : 28 - 39
  • [2] Shear and flexural strengthening of deficient flat slabs with post-installed bolts and CFRP composites bonded through EBR and EBROG
    Torabian, Ala
    Isufi, Brisid
    Mostofinejad, Davood
    Pinho Ramos, Antonio
    STRUCTURAL CONCRETE, 2021, 22 (02) : 1147 - 1164
  • [3] Strengthening of Flat Slabs Against Punching Shear Using Post-Installed Shear Reinforcement
    Ruiz, Miguel Fernandez
    Muttoni, Aurelio
    Kunz, Jakob
    ACI STRUCTURAL JOURNAL, 2010, 107 (04) : 434 - 442
  • [4] Behavior of RC flat slabs with shear bolts under reversed horizontal cyclic loading
    Almeida, Andre F. O.
    Ramos, Antonio P.
    Lucio, Valter
    Marreiros, Rui
    STRUCTURAL CONCRETE, 2020, 21 (02) : 501 - 516
  • [5] Evaluation of design concepts for post-installed punching shear retrofitting
    Olalusi, Oladimeji B.
    Spyridis, Panagiotis
    Strauss, Alfred
    STRUCTURES, 2020, 27 : 1710 - 1721
  • [6] Experimental and numerical evaluation of punching strength of RC flat slabs strengthened using FRP fabrics
    Gowda, C. Prasad
    Ravindra, P. M.
    Puttegowda, B. S.
    MULTISCALE AND MULTIDISCIPLINARY MODELING EXPERIMENTS AND DESIGN, 2024, 7 (02) : 1327 - 1338
  • [7] Post-Installed Shear Connectors: Monitoring a Bridge Strengthened with Coiled Spring Pins
    Hallmark, Robert
    Collin, Peter
    STRUCTURAL ENGINEERING INTERNATIONAL, 2019, 29 (02) : 225 - 233
  • [8] Behavior of post-installed shear connectors under static and fatigue loading
    Kwon, Gunup
    Engelhardt, Michael D.
    Klingner, Richard E.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (04) : 532 - 541
  • [9] Experimental study on shear transfer across interfaces with post-installed shear reinforcement
    Nie, Xin
    Huang, Da
    Liu, Tai
    Fan, Jiansheng
    JOURNAL OF BUILDING ENGINEERING, 2024, 97
  • [10] Bonded anchors with post-installed supplementary reinforcement under tension loading-Experimental investigations
    Vita, Norbert
    Sharma, Akanshu
    Hofmann, Jan
    ENGINEERING STRUCTURES, 2022, 252