Effects of fastener type, end distance, layer arrangement, and panel strength direction on lateral resistance of single shear lap joints in cross-laminated timber (CLT)

被引:11
作者
Abdoli, Farshid [1 ]
Rashidi, Maria [2 ]
Rostampour-Haftkhani, Akbar [3 ]
Layeghi, Mohammad [4 ]
Ebrahimi, Ghanbar [4 ]
机构
[1] Univ Tarbiat Modares, Fac Nat Resources, Dept Wood & Paper Sci, Tehran 13116, Iran
[2] Western Sydney Univ, Ctr Infrastructure Engn, Sydney 2000, Australia
[3] Univ Mohaghegh Ardabili, Fac Agr & Nat Resources, Dept Nat Resources, Wood Sci & Technol, Ardebil 11367, Iran
[4] Univ Tehran, Coll Nat Resources, Dept Wood & Paper Sci & Technol, Karaj, Iran
关键词
Cross-laminated timber; Lateral resistance; Nails; Screws; End distance; Layer arrangement; PERFORMANCE;
D O I
10.1016/j.cscm.2022.e01727
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research investigated the effects of the fastener type, end distance, layer arrangement, and panel strength direction on the lateral resistance of nailed and screwed single shear lap joints in CLT panels. Three-ply CLT panels were made out of poplar wood (Populus alba) with two layer arrangements: 0/90/0 degrees and 0/45/0 degrees. The lateral resistance of nine types of fasteners with end distances of one, two, and three centimeters in two major and minor strength directions of CLT panels was measured by Instron (model 4486) testing machine. The major axis of CLT panels with the 0/45/0 degrees arrangement showed the highest lateral resistance; however, its minor axis showed the lowest one. Among fasteners, Lag screws (10 mm) had the highest lateral resistance, while steel nails had the weakest. In all CLT samples, by changing the fastener type, end distance, layer arrangement, and panel strength direction, the lateral resistance changed 155.8 %, 72.1 %, 3.3 %, and 19.6 %, respectively. Furthermore, changing the failure mode of the fasteners from Im to IV, and CLT members from shear to bearing mode due to the increase in the end distance enhanced lateral resistance, leading to ductile behavior. The NDS, Eurocode 5, and CSA 086 theoretical models were applied to predict the yield lateral loads of the connections. The results showed that Eurocode 5, and CSA 086 better predicted the lateral load of connections with MAPE of 33.8 % and 34.24 %.
引用
收藏
页数:20
相关论文
共 39 条
[1]   Withdrawal Performance of Nails and Screws in Cross-Laminated Timber (CLT) Made of Poplar (Populus alba) and Fir (Abies alba) [J].
Abdoli, Farshid ;
Rashidi, Maria ;
Rostampour-Haftkhani, Akbar ;
Layeghi, Mohammad ;
Ebrahimi, Ghanbar .
POLYMERS, 2022, 14 (15)
[2]  
[Anonymous], 2013, C HDB CROSS LAMINATE, VSP-529E
[3]  
[Anonymous], 1999, ASTM D1037
[4]  
AWC (American Wood Council), 2018, NAT DES SPEC WOOD CO
[5]   Cross laminated timber (CLT): overview and development [J].
Brandner, R. ;
Flatscher, G. ;
Ringhofer, A. ;
Schickhofer, G. ;
Thiel, A. .
EUROPEAN JOURNAL OF WOOD AND WOOD PRODUCTS, 2016, 74 (03) :331-351
[6]   Structural performance of dowelled cross-laminated timber hold-down connections with increased row spacing and end distance [J].
Brown, Justin R. ;
Li, Minghao .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 271
[7]  
Buck D, 2016, BIORESOURCES, V11, P4633
[8]  
C. Group, 2019, O86 CSA
[9]   Structural performance of laminated-bamboo lumber nailed connection [J].
Chen, Guo ;
Yin, Mingyang ;
Wu, Xintao ;
Wang, Zhenguo ;
Jiang, Hao .
WOOD MATERIAL SCIENCE & ENGINEERING, 2022, 17 (06) :989-1001
[10]   Experimental analysis of nailed LBL-to-LBL connections loaded parallel to grain [J].
Chen, Guo ;
Jiang, Hao ;
Yu, Yun-fei ;
Zhou, Tong ;
Wu, Jing ;
Li, Xiang .
MATERIALS AND STRUCTURES, 2020, 53 (04)