Hydrogen sulfide removal from simulated synthesis gas using a hot gas cleaning system

被引:7
|
作者
Ngo, Thi Ngoc Lan Thao [1 ,2 ,3 ]
Chiang, Kung-Yuh [1 ]
机构
[1] Natl Cent Univ, Grad Inst Environm Engn, Tao Yuan City 32001, Taiwan
[2] Ho Chi Minh City Univ Technol HCMUT, Fac Environm & Nat Resources, 268 Ly Thuong Kiet St, Ho Chi Minh City, Vietnam
[3] Vietnam Natl Univ Ho Chi Minh City, Linh Trung Ward, Ho Chi Minh City, Vietnam
来源
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING | 2023年 / 11卷 / 02期
关键词
Hot gas cleaning system; Zeolite; Calcined dolomite; Activated carbon; Hydrogen sulfide; Gasification; DRIED SEWAGE-SLUDGE; H2S REMOVAL; BIOMASS GASIFICATION; ACTIVATED CARBONS; BIOGAS USE; TG-FTIR; TEMPERATURE; ADSORPTION; ENHANCEMENT; PERFORMANCE;
D O I
10.1016/j.jece.2023.109592
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated the removal, adsorption, and regeneration performances of simulated H2S produced from rice straw gasification in a hot gas cleaning system with combination of three types of adsorbents including zeolite, calcined dolomite and activated carbon. These experiments were conducted at 250 degrees C hot gas cleaning system and simulated synthesis gas containing hydrogen sulfide (H2S) concentration at 200 ppm. The experi-mental results indicated that the tested H2S removal efficiency and adsorbed capacity were observed to be adsorbed in decreasing order: activated carbon > calcined dolomite > zeolite. The adsorption capacities of zeolite, calcined dolomite, and activated carbon are 2.22, 3.16, 5.88 mg S/g adsorbents, respectively. In this research, the calcined dolomite shows poor adsorption-regeneration ability due to its deactivation by H2S. However, the tested zeolite and activated carbon could be fully regenerated at 350 degrees C with a stable sulfur adsorption capacity during four adsorption-regeneration cycles. These results gained from this study could significantly support researchers obtaining more information about the synthesis gas contaminants removal during hot gas temperature operation process.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Improving the Synthesis Gas Quality in Catalytic Gasification of Rice Straw by an Integrated Hot-Gas Cleaning System
    Chiang, Kung-Yuh
    Lin, Ming-Hui
    Lu, Cheng-Han
    Chien, Kuang-Li
    Lin, Yun-His
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2015, 12 (10) : 1005 - 1011
  • [2] Hot gas removal of tars, ammonia, and hydrogen sulfide from Biomass gasification gas
    Torres, Walter
    Pansare, Sourabh S.
    Goodwin, James G., Jr.
    CATALYSIS REVIEWS-SCIENCE AND ENGINEERING, 2007, 49 (04): : 407 - 456
  • [3] Hydrogen production enhancement using hot gas cleaning system combined with prepared Ni-based catalyst in biomass gasification
    Thi Ngoc Lan Thao Ngo
    Chiang, Kung-Yuh
    Liu, Chiung-Fang
    Chang, Ying-His
    Wan, Hou-Peng
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (20) : 11269 - 11283
  • [4] Enhanced trace pollutants removal efficiency and hydrogen production in rice straw gasification using hot gas cleaning system
    Ngo Thi Ngoc Lan Thao
    Chiang, Kung-Yuh
    Wan, Hou-Peng
    Hung, Wei-Chun
    Liu, Chiung-Fang
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (06) : 3363 - 3372
  • [5] A Review of Hot Gas Cleaning Techniques for Hydrogen Chloride Removal from Biomass-Derived Syngas
    Marcantonio, Vera
    Mueller, Michael
    Bocci, Enrico
    ENERGIES, 2021, 14 (20)
  • [6] Simultaneous removal of hydrogen sulfide and ammonia in the gas phase: a review
    Jiang, Qi
    Li, Tianguo
    He, Yongmei
    Wu, Yonglin
    Zhang, Jilai
    Jiang, Ming
    ENVIRONMENTAL CHEMISTRY LETTERS, 2022, 20 (02) : 1403 - 1419
  • [7] Gas cleaning with molten tin for hydrogen sulfide and tar in producer gas generated from biomass gasification
    Moon, Jihong
    Jo, Woojin
    Jeong, Soohwa
    Bang, Byungryeul
    Choi, Youngtai
    Hwang, Jungho
    Lee, Uendo
    ENERGY, 2017, 130 : 318 - 326
  • [8] REMOVAL OF CARBONYL SULFIDE AND HYDROGEN-SULFIDE FROM SYNTHESIS GAS BY CHLOROBIUM-THIOSULFATOPHILUM
    BASU, R
    KLASSON, KT
    CLAUSEN, EC
    GADDY, JL
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1994, 45-6 : 787 - 797
  • [9] Effect of multi-component gas on removal of trace hydrogen sulfide activity from blast furnace gas using activated carbon adsorbent
    Wan, Jun
    Liu, Meng
    Liu, Wei
    Ding, Wenxi
    Duan, Yufeng
    INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2024, 22 (08) : 867 - 878
  • [10] Hydrogen sulfide removal from the waste gas of phosphoric acid plant
    Lagha, Arwa
    Ouederni, Abdelmottaleb
    Ben Abdallah, Hedi
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2020, 39 (01)