Generalizable Deep Learning-Based Sleep Staging Approach for Ambulatory Textile Electrode Headband Recordings

被引:6
作者
Rusanen, Matias [1 ,2 ]
Huttunen, Riku [1 ,2 ]
Korkalainen, Henri [1 ,2 ]
Myllymaa, Sami [1 ,2 ]
Toeyraes, Juha [1 ,3 ,4 ]
Myllymaa, Katja [1 ,2 ]
Sigurdardottir, Sigridur [5 ]
Olafsdottir, Kristin A. [5 ]
Leppaenen, Timo [1 ,2 ,4 ]
Arnardottir, Erna S. [5 ,6 ]
Kainulainen, Samu [1 ,2 ]
机构
[1] Univ Eastern Finland, Dept Tech Phys, FI-70211 Kuopio, Finland
[2] Kuopio Univ Hosp, Diagnost Imaging Ctr, FI-70211 Kuopio, Finland
[3] Kuopio Univ Hosp, Sci Serv Ctr, FI-70211 Kuopio, Finland
[4] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, QLD 4067, Australia
[5] Reykjavik Univ, Sch Technol, Sleep Inst, IS-102 Reykjavik, Iceland
[6] Landspitali Natl Univ Hosp Iceland, IS-101 Reykjavik, Iceland
基金
欧盟地平线“2020”; 芬兰科学院;
关键词
Sleep; Electrodes; Recording; Electroencephalography; Textiles; Electrooculography; Standards; Deep learning; electrooculography; sleep; textile electrodes; wearables; convolutional neural network; POLYSOMNOGRAPHY; DIAGNOSIS; CENTERS; APNEA;
D O I
10.1109/JBHI.2023.3240437
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Reliable, automated, and user-friendly solutions for the identification of sleep stages in home environment are needed in various clinical and scientific research settings. Previously we have shown that signals recorded with an easily applicable textile electrode headband (FocusBand Technologies, T 2 Green Pty Ltd) contain characteristics similar to the standard electrooculography (EOG, E1-M2). We hypothesize that the electroencephalographic (EEG) signals recorded using the textile electrode headband are similar enough with standard EOG in order to develop an automatic neural network-based sleep staging method that generalizes from diagnostic polysomnographic (PSG) data to ambulatory sleep recordings of textile electrode-based forehead EEG. Standard EOG signals together with manually annotated sleep stages from clinical PSG dataset (n = 876) were used to train, validate, and test a fully convolutional neural network (CNN). Furthermore, ambulatory sleep recordings including a standard set of gel-based electrodes and the textile electrode headband were conducted for 10 healthy volunteers at their homes to test the generalizability of the model. In the test set (n = 88) of the clinical dataset, the model's accuracy for 5-stage sleep stage classification was 80% (? = 0.73) using only the single-channel EOG. The model generalized well for the headband-data, reaching 82% (? = 0.75) overall sleep staging accuracy. In comparison, accuracy of the model was 87% (? = 0.82) in home recordings using the standard EOG. In conclusion, the CNN model shows potential on automatic sleep staging of healthy individuals using a reusable electrode headband in a home environment.
引用
收藏
页码:1869 / 1880
页数:12
相关论文
共 56 条
[21]   Limitations of Rechtschaffen and Kales [J].
Himanen, SL ;
Hasan, J .
SLEEP MEDICINE REVIEWS, 2000, 4 (02) :149-167
[22]   Home-Use and Real-Time Sleep-Staging System Based on Eye Masks and Mobile Devices with a Deep Learning Model [J].
Hsieh, Tsung-Hao ;
Liu, Meng-Hsuan ;
Kuo, Chin-En ;
Wang, Yung-Hung ;
Liang, Sheng-Fu .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2021, 41 (05) :659-668
[23]  
Hu J, 2018, PROC CVPR IEEE, P7132, DOI [10.1109/CVPR.2018.00745, 10.1109/TPAMI.2019.2913372]
[24]   Deep Transfer Learning for Single-Channel Automatic Sleep Staging with Channel Mismatch [J].
Huy Phan ;
Chen, Oliver Y. ;
Koch, Philipp ;
Mertins, Alfred ;
De Vos, Maarten .
2019 27TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2019,
[25]   A Systematic Review of Sensing Technologies for Wearable Sleep Staging [J].
Imtiaz, Syed Anas .
SENSORS, 2021, 21 (05) :1-21
[26]   Comparison of EEG Signal Characteristics Between Polysomnography and Self Applied Somnography Setup in a Pediatric Cohort [J].
Kainulainen, Samu ;
Korkalainen, Henri ;
Sigurdardottir, Sigriur ;
Myllymaa, Sami ;
Serwatko, Marta ;
Sigurdardottir, Sigurveig Pora ;
Clausen, Michael ;
Leppanen, Timo ;
Arnardottir, Erna Sif .
IEEE ACCESS, 2021, 9 :110916-110926
[27]   Self-Applied Home Sleep Recordings The Future of Sleep Medicine [J].
Korkalainen, Henri ;
Nikkonen, Sami ;
Kainulainen, Samu ;
Dwivedi, Amit Krishna ;
Myllymaa, Sami ;
Leppanen, Timo ;
Toyras, Juha .
SLEEP MEDICINE CLINICS, 2021, 16 (04) :545-556
[28]   Accurate Deep Learning-Based Sleep Staging in a Clinical Population With Suspected Obstructive Sleep Apnea [J].
Korkalainen, Henri ;
Aakko, Juhani ;
Nikkonen, Sami ;
Kainulainen, Samu ;
Leino, Akseli ;
Duce, Brett ;
Afara, Isaac O. ;
Myllymaa, Sami ;
Toyras, Juha ;
Leppanen, Timo .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (07) :2073-2081
[29]   A Protocol for Comparing Dry and Wet EEG Electrodes During Sleep [J].
Leach, Sven ;
Chung, Ku-young ;
Tushaus, Laura ;
Huber, Reto ;
Karlen, Walter .
FRONTIERS IN NEUROSCIENCE, 2020, 14
[30]   Interrater reliability of sleep stage scoring: a meta-analysis [J].
Lee, Yun Ji ;
Lee, Jae Yong ;
Cho, Jae Hoon ;
Choi, Ji Ho .
JOURNAL OF CLINICAL SLEEP MEDICINE, 2022, 18 (01) :193-202