Improvement of intermediate vision with new monofocal intraocular lenses: A systematic review and meta-analysis

被引:8
作者
Redruello-Guerrero, Pablo [1 ,2 ]
Rivera-Izquierdo, Mario [3 ,4 ]
Jimenez-Gutierrez, Carmen [5 ]
Jesus Lainez-Ramos-Bossini, Antonio [6 ]
Yela, Ruben [1 ]
Lopez-Marin, Ignacio [1 ]
机构
[1] Visioon Clin Ctr, Ophthalmol Dept, Granada, Spain
[2] Univ Granada, Dept Human Anat & Embryol, Granada, Spain
[3] Univ Granada, Dept Prevent Med & Publ Hlth, Granada, Spain
[4] San Cecilio Univ Hosp, Dept Prevent Med & Publ Hlth, Granada, Spain
[5] Univ Granada, Dept Nursing, Granada, Spain
[6] Virgen de las Nieves Univ Hosp, Radiol Dept, Granada, Spain
关键词
Cataract; intraocular lens; ICB00; tecnis eyhance; intermediate vision; meta-analysis; EXTENDED DEPTH; IOLS; QUALITY;
D O I
10.1177/11206721221127075
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Monofocal intraocular lenses (IOLs) used in cataract surgery are designed to improve visual acuity (VA). The available evidence of new monofocal IOLs" functional benefits is limited. The aim of this meta-analysis was to analyze the improvement in VA using Tecnis Eyhance monofocal IOLs compared to standard monofocal IOLs Tecnis ZCB00. Methods MEDLINE, Web of Science and Scopus were searched for studies assessing improvement in intermediate VA using Tecnis Eyhance IOLs versus Tecnis ZCB00 IOLs. Studies evaluating post-operative VA in patients who underwent cataract surgery were selected. This meta-analysis followed PRISMA guidelines and was registered in PROSPERO. The Cochrane Risk of Bias Tool 2.0. was used to assess the methodological quality of the included studies, risk of selection bias and comparability of cohorts and outcomes. Results The search resulted in 1153 articles. Five studies met the inclusion criteria and were included in the meta-analysis. A total of 604 eyes were evaluated, of which 309 received Tecnis Eyhance IOLs and 295 were implanted with Tecnis ZCB00 IOLs. Mean binocular distant-corrected intermediate VA with Tecnis Eyhance IOLs at 2 weeks-1 month showed a significant difference of -0,21 logMAR, p < 0.001; and mean binocular distance-corrected intermediate VA with Tecnis Eyhance IOLs at 6 months showed a significant difference of -0,11 logMAR, p < 0.001. Conclusion Near VA could not be assessed in this meta-analysis as it was measured in very few studies. Preliminary pooled evidence indicates that intermediate VA improved with Tecnis Eyhance IOLs. Further studies evaluating near VA and with longer follow-up are still necessary.
引用
收藏
页码:1308 / 1319
页数:12
相关论文
共 19 条
  • [1] Clinical evaluation of a new monofocal IOL with enhanced intermediate function in patients with cataract
    Auffarth, Gerd U.
    Gerl, Matthias
    Tsai, Linda
    Janakiraman, D. Priya
    Jackson, Beth
    Alarcon, Aixa
    Dick, H. Burkhard
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (02) : 184 - 191
  • [2] de Luis Eguileor B, 2020, Arch Soc Esp Oftalmol (Engl Ed), V95, P523, DOI 10.1016/j.oftal.2020.06.009
  • [3] Guirao A, 2002, ARCH OPHTHALMOL-CHIC, V120, P1143
  • [4] Measuring inconsistency in meta-analyses
    Higgins, JPT
    Thompson, SG
    Deeks, JJ
    Altman, DG
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7414): : 557 - 560
  • [5] Khalafallah A, 2010, MEDITERR J HEMATOL I, V2, DOI [10.4084/MJHID.2010.005, 10.1136/bmj.l4898]
  • [6] Long-term Effect of Intraocular Lens vs Contact Lens Correction on Visual Acuity After Cataract Surgery During Infancy A Randomized Clinical Trial
    Lambert, Scott R.
    Cotsonis, George
    DuBois, Lindreth
    Nizam, Azhar
    Kruger, Stacey J.
    Hartmann, E. Eugenie
    Weakley, David R., Jr.
    Drews-Botsch, Carolyn
    [J]. JAMA OPHTHALMOLOGY, 2020, 138 (04) : 365 - 372
  • [7] Special Report: American Academy of Ophthalmology Task Force Consensus Statement for Extended Depth of Focus Intraocular Lenses
    MacRae, Scott
    Holladay, Jack T.
    Glasser, Adrian
    Calogero, Don
    Hilmantel, Gene
    Masket, Samuel
    Stark, Walter
    Tarver, Michelle E.
    Nguyen, Tieuvi
    Eydelman, Malvina
    [J]. OPHTHALMOLOGY, 2017, 124 (01) : 139 - 141
  • [8] Visual outcome, optical quality, and patient satisfaction with a new monofocal IOL, enhanced for intermediate vision: preliminary results
    Mencucci, Rita
    Cennamo, Michela
    Venturi, Daniel
    Vignapiano, Roberto
    Favuzza, Eleonora
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (03) : 378 - 387
  • [9] Moher D, 2010, INT J SURG, V8, P336, DOI [10.1016/j.ijsu.2010.02.007, 10.1136/bmj.b2700, 10.1371/journal.pmed.1000097, 10.1186/2046-4053-4-1, 10.1016/j.ijsu.2010.07.299, 10.1136/bmj.b2535, 10.1136/bmj.i4086]
  • [10] Accommodative intraocular lens versus standard monofocal intraocular lens implantation in cataract surgery
    Ong, Hon Shing
    Evans, Jennifer R.
    Allan, Bruce D. S.