False-Positive and False-Negative Contrast-enhanced Mammograms: Pitfalls and Strategies to Improve Cancer Detection

被引:5
作者
Carnahan, Molly B. [1 ]
Harper, Laura [1 ]
Brown, Parker J. [1 ]
Bhatt, Asha A. [2 ]
Eversman, Sarah [1 ]
Sharpe, Richard E. [1 ]
Patel, Bhavika K. [1 ]
机构
[1] Mayo Clin Arizona, Dept Radiol, 5777 E Mayo Blvd, Phoenix, AZ 85054 USA
[2] Mayo Clin Rochester, Dept Radiol, Rochester, MN USA
关键词
IDIOPATHIC GRANULOMATOUS MASTITIS; BREAST MRI; IMAGING CHARACTERISTICS; SPECTRAL MAMMOGRAPHY; DIGITAL MAMMOGRAPHY; FAT NECROSIS; LESIONS; WOMEN; FEATURES; CARCINOMA;
D O I
10.1148/rg.230100
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Contrast-enhanced mammography (CEM) is a relatively new breast imaging modality that uses intravenous contrast material to increase detection of breast cancer. CEM combines the structural information of conventional mammog-raphy with the functional information of tumor neovascularity. Initial studies have demonstrated that CEM and MRI perform with similar accuracies, with CEM having a slightly higher specificity (fewer false positives), although larger studies are needed. There are various reasons for false positives and false neg-atives at CEM. False positives at CEM can be caused by benign lesions with vascularity, including benign tumors, infection or inflammation, benign lesions in the skin, and imaging artifacts. False negatives at CEM can be attributed to incomplete or inadequate visualization of lesions, marked background parenchymal enhancement (BPE) obscuring cancer, lack of lesion contrast enhancement due to technical issues or less-vascular cancers, artifacts, and errors of lesion perception or characterization. When possible, real-time interpretation of CEM studies is ideal. If additional views are necessary, they may be obtained while contrast material is still in the breast pa-renchyma. Until recently, a limitation of CEM was the lack of CEM-guided biopsy capability. However, in 2020, the U.S. Food and Drug Administration cleared two devices to support CEM-guided biopsy us-ing a stereotactic biopsy technique. The authors review various causes of false-positive and false-negative contrast-enhanced mammograms and discuss strategies to reduce these diagnostic errors to improve cancer detection while mitigating unnecessary additional imaging and procedures.
引用
收藏
页数:18
相关论文
共 77 条
[1]   Contrast-Enhanced Digital Mammography in the Surgical Management of Breast Cancer [J].
Ali-Mucheru, Mariam ;
Pockaj, Barbara ;
Patel, Bhavika ;
Pizzitola, Victor ;
Wasif, Nabil ;
Stucky, Chee-Chee ;
Gray, Richard .
ANNALS OF SURGICAL ONCOLOGY, 2016, 23 :S649-S655
[2]   Comparison of False-Positive Versus True-Positive Findings on Contrast-Enhanced Digital Mammography [J].
Amir, Tali ;
Hogan, Molly P. ;
Jacobs, Stefanie ;
Sevilimedu, Varadan ;
Sung, Janice ;
Jochelson, Maxine S. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (05) :797-808
[3]  
[Anonymous], 2020, Affirm Contrast Biopsy510(k)premarketnotificationsubmissionapproval letter
[4]  
[Anonymous], 2007, Breast Imaging
[5]  
[Anonymous], 2020, Pristina Serena Bright 510(k) premarket notification submission approval letter
[6]   False-Positive Findings at Contrast-Enhanced Breast MRI: A BI-RADS Descriptor Study [J].
Baltzer, Pascal A. T. ;
Benndorf, Matthias ;
Dietzel, Matthias ;
Gajda, Mieczyslaw ;
Runnebaum, Ingo B. ;
Kaiser, Werner A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (06) :1658-1663
[7]   MAMMOGRAPHIC POSITIONING - EVALUATION FROM THE VIEW BOX [J].
BASSETT, LW ;
HIRBAWI, IA ;
DEBRUHL, N ;
HAYES, MK .
RADIOLOGY, 1993, 188 (03) :803-806
[8]   Papillary lesions of the breast diagnosed by core needle biopsy: 71 cases with surgical follow-up [J].
Bernik, Stephanie F. ;
Troob, Scott ;
Ying, Benjamin L. ;
Simpson, Scott A. ;
Axelrod, Deborah M. ;
Siegel, Beth ;
Moncrief, Robyn M. ;
Mills, Christopher ;
Aziz, Mohamed .
AMERICAN JOURNAL OF SURGERY, 2009, 197 (04) :473-478
[9]   Contrast-enhanced Spectral Mammography: Technique, Indications, and Clinical Applications [J].
Bhimani, Chandni ;
Matta, Danielle ;
Roth, Robyn G. ;
Liao, Lydia ;
Tinney, Elizabeth ;
Brill, Kristin ;
Germaine, Pauline .
ACADEMIC RADIOLOGY, 2017, 24 (01) :84-88
[10]   Intramammary lymph nodes: normal and abnormal multimodality imaging features [J].
Bitencourt, Almir G., V ;
Ferreira, Eduardo V. L. ;
Bastos, David C. ;
Sperandio, Vitor A. ;
Graziano, Luciana ;
Guatelli, Camila S. ;
Albuquerque, Maria L. L. ;
Souza, Juliana A. ;
Marques, Elvira F. .
BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1103)