Influence of seasonal and operator variations on diagnostic accuracy of lateral flow devices during the COVID-19 pandemic: a systematic review and meta-analysis

被引:5
作者
Krishnamoorthy, Ashwin [1 ,2 ]
Chandrapalan, Subashini [1 ]
JalayeriNia, Gohar [1 ]
Hussain, Yaqza [1 ]
Bannaga, Ayman [1 ]
Lei, Ian Io [1 ]
Arasaradnam, Ramesh [1 ]
机构
[1] Univ Hosp Coventry & Warwickshire NHS Trust, Coventry, England
[2] Univ Hosp Coventry & Warwickshire, Res & Dev, Clifford Bridge Rd, Coventry CV2 2DX, England
关键词
coronavirus; COVID-19; SARS-CoV-2; viral antigen detection; rapid antigen test;
D O I
10.7861/clinmed.2022-0319
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Lateral flow tests (LFT) are point-of-care rapid antigen tests that allow isolation and control of disease outbreaks through convenient, practical testing. However, studies have shown significant variation in their diagnostic accuracy. We conducted a systematic review of the diagnostic accuracy of LFTs for the detection of severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) to identify potential factors affecting their performance. Methods A systematic search of online databases was carried out to identify studies assessing the sensitivity and specificity of LFTs compared with polymerase chain reaction (PCR) tests. Data were extracted and used to calculate pooled sensitivity and specificity. Meta-regression analysis was conducted to identify covariates influencing diagnostic accuracy. Results In total, 76 articles with 108,820 test results were identified for analysis. Pooled sensitivity and specificity were 72% (95% confidence interval (CI): 0.68-0.76) and 100% (95% CI: 0.99-1.00), respectively. Staff operation of the LFT showed a statistically significant increase in sensitivity (p=0.04) and specificity (p=0.001) compared with self-operation by the test subjects. The use of LFTs in symptomatic patient subgroups also resulted in higher test sensitivity. Conclusion LFTs display good sensitivity and extremely good specificity for SARS-CoV-2 antigen detection; they become more sensitive in patients with symptoms and when performed by trained professionals.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 15 条
[11]   Testing at scale during the COVID-19 pandemic [J].
Mercer, Tim R. ;
Salit, Marc .
NATURE REVIEWS GENETICS, 2021, 22 (07) :415-426
[12]   A systematic review of the sensitivity and specificity of lateral flow devices in the detection of SARS-CoV-2 [J].
Mistry, Dylan A. ;
Wang, Jenny Y. ;
Moeser, Mika-Erik ;
Starkey, Thomas ;
Lee, Lennard Y. W. .
BMC INFECTIOUS DISEASES, 2021, 21 (01)
[13]   Diagnostic test accuracy:application and practice using R software [J].
Shim, Sung Ryul ;
Kim, Seong-Jang ;
Lee, Jonghoo .
EPIDEMIOLOGY AND HEALTH, 2019, 41
[14]   Self-testing for the detection of SARS-CoV-2 infection with rapid antigen tests for people with suspected COVID-19 in the community [J].
Stohr, Joep J. J. M. ;
Zwart, Vivian F. ;
Goderski, Gabriel ;
Meijer, Adam ;
Nagel-Imming, Carla R. S. ;
Kluytmans-van den Bergh, Marjolein F. Q. ;
Pas, Suzan D. ;
van den Oetelaar, Femke ;
Hellwich, Marloes ;
Gan, Kim H. ;
Rietveld, Ariene ;
Verweij, Jaco J. ;
Murk, Jean-Luc ;
van den Bijllaardt, Wouter ;
Kluytmans, Jan A. J. W. .
CLINICAL MICROBIOLOGY AND INFECTION, 2022, 28 (05) :695-700
[15]  
World Health Organization, 2020, COVID-19 Target product profiles for priority diagnostics to support response to the COVID-19 pandemic v.0.1