NeuTHOR Station-A Novel Integrated Platform for Monitoring BNCT Clinical Treatment, Animal and Cell Irradiation Study at THOR

被引:5
作者
Huang, Yu-Shiang [1 ]
Peir, Jinn-Jer [1 ]
Wu, Chuan-Jen [1 ]
Wang, Mei-Ya [1 ]
Chen, Yi-Wei [2 ,3 ]
Lee, Jia-Cheng [2 ,3 ]
Chou, Fong-In [1 ,4 ]
机构
[1] Natl Tsing Hua Univ, Nucl Sci & Technol Dev Ctr, Hsinchu, Taiwan
[2] Taipei Vet Gen Hosp, Dept Heavy Particles & Radiat Oncol, Taipei 11217, Taiwan
[3] Yuanpei Univ Med Technol, Dept Med Imaging & Radiol Technol, Hsinchu 30015, Taiwan
[4] Natl Tsing Hua Univ, Inst Nucl Engn & Sci, Hsinchu 300044, Taiwan
来源
LIFE-BASEL | 2023年 / 13卷 / 03期
关键词
NeuTHOR Station; integrated platform; BNCT; THOR; NEUTRON-CAPTURE THERAPY; LOCALLY RECURRENT HEAD; ACID-MEDIATED BNCT; BORIC-ACID; NECK-CANCER; DNA-DAMAGE; SYSTEM; EFFICACY; AGENT; TUMOR;
D O I
10.3390/life13030800
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
(1) Background: A well-established Boron Neutron Capture Therapy (BNCT) facility includes many essential systems, which are the epithermal neutron beam system, on-line monitoring system (OMS), QA/QC (quality assurance or quality control) system, boron concentration (BC) measurement system, and treatment planning system (TPS). Accurate data transmission, monitoring, and deposition among these systems are of vital importance before, during, and after clinical, animal, and cell BNCT irradiation. This work developed a novel integrated platform NeuTHOR Station (NeuTHORS) for BNCT at Tsing Hua Open-pool Reactor (THOR). Apart from the data of the OMS and QA/QC system, the data of BC and TPS can be loaded on NeuTHORS before BNCT clinical, animal, and cell irradiation. (2) Methods: A multi-paradigm computer programming language c# (c sharp) was used to develop the integrated platform NeuTHORS. The design of NeuTHORS is based on the standard procedures of BNCT treatment or experiment at THOR. Moreover, parallel testing with OMS-BNCT (the former OMS) and QA/QC of THOR was also performed for more than 70 times to verify the validation of NeuTHORS. (3) Results: According to the comparisons of the output, NeuTHORS and OMS-BNCT and QA/QC of THOR show very good consistency. NeuTHORS is now installed on an industrial PC (IPC) and successfully performs the monitoring of BNCT Treatment at THOR. Patients' f BC and TPS data are also input into NeuTHORS and stored on IPC through an internal network from BC measurement room and TPS physicist. Therefore, the treatment data of each patient can be instantaneously established after each BNCT treatment for further study on BNCT. NeuTHORS can also be applied on data acquisition for a BNCT-related study, especially for animal or cell irradiation experiments. (4) Conclusions: A novel integrated platform NeuTHOR Station for monitoring BNCT clinical treatment and animal and cell irradiation study has been successfully established at THOR. With this platform, BNCT radiobiology investigations will be efficiently performed and a thorough data storage and analysis system of BNCT treatments or experiments can thus be systematically built up for the further investigation of BNCT at THOR.
引用
收藏
页数:15
相关论文
共 33 条
  • [1] A realistic appraisal of boron neutron capture therapy as a cancer treatment modality
    Barth, Rolf F.
    Zhang, Zizhu
    Liu, Tong
    [J]. CANCER COMMUNICATIONS, 2018, 38
  • [2] Demonstration of the importance of a dedicated neutron beam monitoring system for BNCT facility
    Chao, Der-Sheng
    Liu, Yuan-Hao
    Jiang, Shiang-Huei
    [J]. APPLIED RADIATION AND ISOTOPES, 2016, 107 : 312 - 316
  • [3] Analysis of DNA Damage Responses After Boric Acid-mediated Boron Neutron Capture Therapy in Hepatocellular Carcinoma
    Chen, Kuan-Hao
    Lai, Zih-Yin
    Li, Ding-Yu
    Lin, Yu-Chuan
    Chou, Fong-In
    Chuang, Yung-Jen
    [J]. ANTICANCER RESEARCH, 2019, 39 (12) : 6661 - 6671
  • [4] Chen Y.-W., 2020, Ther Radiol Oncol, V4, P30, DOI [10.21037/tro-20-20, DOI 10.21037/TRO-20-20]
  • [5] Compassionate Treatment of Brainstem Tumors with Boron Neutron Capture Therapy: A Case Series
    Chen, Yi-Wei
    Lee, Yi-Yen
    Lin, Chun-Fu
    Huang, Ting-Yu
    Ke, Shih-Hung
    Mu, Pei-Fan
    Pan, Po-Shen
    Chen, Jen-Kun
    Lan, Tien-Li
    Hsu, Ping-Chuan
    Liang, Muh-Lii
    Chen, Hsin-Hung
    Chang, Feng-Chi
    Wu, Chih-Chun
    Lin, Shih-Chieh
    Lee, Jia-Cheng
    Chen, Shih-Kuan
    Liu, Hong-Ming
    Peir, Jinn-Jer
    Tsai, Hui-Yu
    Lin, Ko-Han
    Peng, Nan-Jing
    Chen, Kuan-Hsuan
    Wu, Yuan-Hung
    Kang, Yu-Mei
    Yang, Wan-Chin
    Liou, Shueh-Chun
    Huang, Wei-Hsuan
    Tanaka, Hiroki
    Wong, Tai-Tong
    Chao, Yee
    Chou, Fong-In
    [J]. LIFE-BASEL, 2022, 12 (04):
  • [6] Salvage Boron Neutron Capture Therapy for Malignant Brain Tumor Patients in Compliance with Emergency and Compassionate Use: Evaluation of 34 Cases in Taiwan
    Chen, Yi-Wei
    Lee, Yi-Yen
    Lin, Chun-Fu
    Pan, Po-Shen
    Chen, Jen-Kun
    Wang, Chun-Wei
    Hsu, Shih-Ming
    Kuo, Yu-Cheng
    Lan, Tien-Li
    Hsu, Sanford P. C.
    Liang, Muh-Lii
    Chen, Robert Hsin-Hung
    Chang, Feng-Chi
    Wu, Chih-Chun
    Lin, Shih-Chieh
    Liang, Hsiang-Kuang
    Lee, Jia-Cheng
    Chen, Shih-Kuan
    Liu, Hong-Ming
    Peir, Jinn-Jer
    Lin, Ko-Han
    Huang, Wen-Sheng
    Chen, Kuan-Hsuan
    Kang, Yu-Mei
    Liou, Shueh-Chun
    Wang, Chun-Chieh
    Pai, Ping-Ching
    Li, Chih-Wei
    Chiek, Daniel Quah Song
    Wong, Tai-Tong
    Chiou, Shih-Hwa
    Chao, Yee
    Tanaka, Hiroki
    Chou, Fong-In
    Ono, Koji
    [J]. BIOLOGY-BASEL, 2021, 10 (04):
  • [7] Chou FI, 1999, ANTICANCER RES, V19, P1759
  • [8] Potential of using boric acid as a boron drug for boron neutron capture therapy for osteosarcoma
    Hsu, C. F.
    Lin, S. Y.
    Peir, J. J.
    Liao, J. W.
    Lin, Y. C.
    Chou, F. I.
    [J]. APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1782 - 1785
  • [9] Boron Neutron Capture Therapy Eliminates Radioresistant Liver Cancer Cells by Targeting DNA Damage and Repair Responses
    Huang, Chu-Yu
    Lai, Zih-Yin
    Hsu, Tzu-Jung
    Chou, Fong-In
    Liu, Hong-Ming
    Chuang, Yung-Jen
    [J]. JOURNAL OF HEPATOCELLULAR CARCINOMA, 2022, 9 : 1385 - 1401
  • [10] Suitability of boric acid as a boron drug for boron neutron capture therapy for hepatoma
    Hung, Yi-Hsuan
    Lin, Yu-Chuan
    Lin, Yu-Ting
    Shih, Guan-Wen
    Liao, Jiunn-Wang
    Chen, Kuan-Sheng
    Liu, Hong-Ming
    Chen, Yi-Wei
    Chuang, Yung-Jen
    Yang, Chia-Min
    Peir, Jinn-Jer
    Yang, Chin-Hua
    Chou, Fong-In
    [J]. APPLIED RADIATION AND ISOTOPES, 2020, 164