Simulation and economic analysis of the high-temperature heat storage system of thermal power plants oriented to the smart grid

被引:4
作者
Zhang, Hongwei [1 ]
Zhao, Mingyuan [2 ]
Li, Yanbing [2 ]
Liu, Junqing [1 ]
Liang, Wenbin [1 ]
机构
[1] Natl Inst Clean & Low Carbon Energy, Beijing, Peoples R China
[2] CHN Energy Jinjie Energy Co Ltd, Yulin, Peoples R China
关键词
smart grid (SG); high temperature; thermal energy storage (TES); economic analysis (EA); thermal power plant (TPP); ENERGY-STORAGE; COOLING PROCESS; PERFORMANCE; SALT; OPTIMIZATION; MANAGEMENT; ELECTRICITY; EMISSIONS; TANKS;
D O I
10.3389/fenrg.2022.1006972
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the continuous increase of the grid-connected proportion of intermittent renewable energy, in order to ensure the reliability of smart grid operation, it is urgent to improve the operational flexibility of thermal power plants. Electric heat storage technology has broad prospects in terms of in-depth peak shaving of power grids, improving new energy utilization rates and improving the environment. It is an important means to promote electric energy substitution. In this study, the economics of technical application scenarios are compared and analyzed, the principle of solid heat storage technology is discussed, and its application in heating fields such as industrial steam, district heating, and deep peak regulation of congeneration units is expounded. The results indicate that in the scenario where the peak shaving subsidy and the heat storage duration are the same, as the unit output increases, the investment recovery period increases. Moreover, the results also indicate that in the 0.3 yuan/kW power market peaking subsidy scenario, only when the unit output is 0 and the heat storage time is greater than 8 h, the investment can be recovered in 5 years, while in the 0.7 yuan/kW power market peaking subsidy scenario, except for the scenario where the unit output is 40% and the heat storage time is 7 h, the investment cannot be recovered; in other scenarios, the investment can be recovered within 5 years.
引用
收藏
页数:9
相关论文
共 76 条
[1]   Joint Energy Management and Energy Trading in Residential Microgrid System [J].
Ahmad, Sadiq ;
Alhaisoni, Majed M. ;
Naeem, Muhammad ;
Ahmad, Ayaz ;
Altaf, Muhammad .
IEEE ACCESS, 2020, 8 :123334-123346
[2]  
Andersen T. V., 2009, INTEGRATION 50 WIND
[3]  
Bai Z.H., 2019, Distribution & Utilization, V36, P20
[4]   Optimization methods applied to renewable and sustainable energy: A review [J].
Banos, R. ;
Manzano-Agugliaro, F. ;
Montoya, F. G. ;
Gil, C. ;
Alcayde, A. ;
Gomez, J. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (04) :1753-1766
[5]  
Bejan A., 1995, Thermal design and optimization
[6]  
Cao Min, 2019, Power DSM, V21, P52
[7]  
Chinese Government, 2020, CER PRES FLOW BASK P
[8]  
[邓佳乐 Deng Jiale], 2016, [电力系统自动化, Automation of Electric Power Systems], V40, P41
[9]   Improved accounting of emissions from utility energy storage system operation [J].
Denholm, P ;
Holloway, T .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (23) :9016-9022
[10]   Life cycle energy requirements and greenhouse gas emissions from large scale energy storage systems [J].
Denholm, P ;
Kulcinski, GL .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (13-14) :2153-2172