Verification of the active pharmaceutical ingredient in tablets using a low-cost near-infrared spectrometer

被引:5
作者
Gabel, Julia [1 ]
Gnegel, Gesa [1 ]
Kessler, Waltraud [2 ]
Sacre, Pierre-Yves [3 ]
Heide, Lutz [1 ]
机构
[1] Eberhard Karls Univ Tubingen, Pharmaceut Inst, D-72070 Tubingen, Germany
[2] Reutlingen Univ, Sch Life Sci, D-72762 Reutlingen, Germany
[3] Univ Liege ULiege, Dept Pharm, Res Support Unit Chemometr, CIRM, B-4000 Liege, Belgium
来源
TALANTA OPEN | 2023年 / 8卷
关键词
Near -infrared spectroscopy; Pharmaceuticals; Medicine quality; Substandard and falsified medicines; DD-SIMCA; Authentication; HAND-HELD NIR; SPECTROSCOPY; STANDARDIZATION; MEDICINES;
D O I
10.1016/j.talo.2023.100270
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present study investigated the possibilities and limitations of using a low-cost NIR spectrometer for the verification of the presence of the declared active pharmaceutical ingredients (APIs) in tablet formulations, especially for medicine screening studies in low-resource settings. Spectra from 950 to 1650 nm were recorded for 170 pharmaceutical products representing 41 different APIs, API combinations or placebos. Most of the products, including 20 falsified medicines, had been collected in medicine quality studies in African countries. After exploratory principal component analysis, models were built using data-driven soft independent modelling of class analogy (DD-SIMCA), a one-class classifier algorithm, for tablet products of penicillin V, sulfamethox-azole/trimethoprim, ciprofloxacin, furosemide, metronidazole, metformin, hydrochlorothiazide, and doxycy-cline. Spectra of amoxicillin and amoxicillin/clavulanic acid tablets were combined into a single model. Models were tested using Procrustes cross-validation and by projection of spectra of tablets containing the same or different APIs. Tablets containing no or different APIs could be identified with 100 % specificity in all models. A separation of the spectra of amoxicillin and amoxicillin/clavulanic acid tablets was achieved by partial least squares discriminant analysis. 15 out of 19 external validation products (79 %) representing different brands of the same APIs were correctly identified as members of the target class; three of the four rejected samples showed an API mass percentage of the total tablet weight that was out of the range covered in the respective calibration set. Therefore, in future investigations larger and more representative spectral libraries are required for model building. Falsified medicines containing no API, incorrect APIs, or grossly incorrect amounts of the declared APIs could be readily identified. Variation between different NIR-S-G1 spectroscopic devices led to a loss of accuracy if spectra recorded with different devices were pooled. Therefore, piecewise direct standardization was applied for calibration transfer. The investigated method is a promising tool for medicine screening studies in low-resource settings.
引用
收藏
页数:16
相关论文
共 70 条
[1]  
[Anonymous], 2010, ASSESSMENT MED REGUL
[2]   Discrimination of Substandard and Falsified Formulations from Genuine Pharmaceuticals Using NIR Spectra and Machine Learning [J].
Awotunde, Olatunde ;
Roseboom, Nicholas ;
Cai, Jin ;
Hayes, Kathleen ;
Rajane, Revati ;
Chen, Ruoyan ;
Yusuf, Abdullah ;
Lieberman, Marya .
ANALYTICAL CHEMISTRY, 2022, 94 (37) :12586-12594
[3]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[4]   Improvement of the piecewise direct standardisation procedure for the transfer of NIR spectra for multivariate calibration [J].
Bouveresse, E ;
Massart, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 32 (02) :201-213
[5]   Principal component analysis [J].
Bro, Rasmus ;
Smilde, Age K. .
ANALYTICAL METHODS, 2014, 6 (09) :2812-2831
[6]  
Buckley G.J., 2013, COUNTERING PROBLEM F
[7]   OPLS discriminant analysis:: combining the strengths of PLS-DA and SIMCA classification [J].
Bylesjo, Max ;
Rantalainen, Mattias ;
Cloarec, Olivier ;
Nicholson, Jeremy K. ;
Holmes, Elaine ;
Trygg, Johan .
JOURNAL OF CHEMOMETRICS, 2006, 20 (8-10) :341-351
[8]   A comparative field evaluation of six medicine quality screening devices in Laos [J].
Caillet, Celine ;
Vickers, Serena ;
Zambrzycki, Stephen ;
Fernandez, Facundo N. ;
Vidhamaly, Vayouly ;
Boutsamay, Kem ;
Boupha, Phonepasith ;
Peerawaranun, Pimnara ;
Mukaka, Mavuto ;
Newton, Paul .
PLOS NEGLECTED TROPICAL DISEASES, 2021, 15 (09)
[9]   Application of near-infrared spectroscopy and class-modeling to antibiotic authentication [J].
Chen, Hui ;
Lin, Zan ;
Tan, Chao .
ANALYTICAL BIOCHEMISTRY, 2020, 590
[10]   Comparison of several strategies for the deployment of a multivariate regression model on several handheld NIR instruments. Application to the quality control of medicines [J].
Ciza, P. H. ;
Sacre, P-Y ;
Waffo, C. ;
Kimbeni, T. M. ;
Masereel, B. ;
Hubert, Ph ;
Ziemons, E. ;
Marini, R. D. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 215