Failure experiment on CFRP-strengthened prestressed concrete cylinder pipe with broken wires

被引:26
作者
Zhai, Kejie [1 ,2 ]
Fang, Hongyuan [1 ]
Li, Bin [1 ]
Guo, Chengchao [2 ]
Yang, Kangjian [1 ]
Du, Xueming [1 ]
Du, Mingrui [1 ]
Wang, Niannian [1 ]
机构
[1] Zhengzhou Univ, Yellow River Lab, Zhengzhou 450001, Peoples R China
[2] Sun Yat Sen Univ, Sch Civil Engn, Guangzhou 510275, Peoples R China
基金
中国国家自然科学基金;
关键词
Prestressed concrete cylinder pipe (PCCP); Broken wires; Carbon fiber reinforced polymer (CFRP); Strain gauging; Failure experiment; COATING DELAMINATION; RADIAL TENSION; PERFORMANCE; PCCP;
D O I
10.1016/j.tust.2023.105032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The prestressed concrete cylinder pipe (PCCP) has been used widely in hydraulic engineering. However, due to hydrogen embrittlement and corrosion, the prestressing wires in PCCP can break and cause pipe failure. In this study, a retrofitting technique of using externally bonded carbon fiber reinforced polymer (CFRP) to repair PCCP was proposed. The technique is particularly useful when shutting down water is not possible. The proposed strategy was evaluated by using a full-scale PCCP with a 2.8 m inside diameter loaded with internal water pressure. First, the PCCP strains before and after repair were compared under different internal pressures. In the presence of CFRP, the strains near the broken wires significantly decreased under the same internal pressure, and the carrying capacity of the PCCP increased. PCCPs with 13 %, 15 %, and 18 % wire breakage ratios were then evaluated and compared. The strain in each material increased with increasing wire breakage ratio, and the maximum strain in CFRP was observed at the location of wire breakage. Considering the PCCP with 18 % wire breakage ratio, the section 2300 mm from the pipe end was in the linear state under an internal pressure of 0-0.9 MPa, and the PCCP reached its serviceability and elastic limit states when the internal pressure increased to about 1.0 MPa and 1.2 MPa, respectively. Finally, when the internal water pressure was increased to 1.27 MPa, which was higher than the internal design pressure of 1.12 MPa, the PCCP failed due to the rupture of CFRP.
引用
收藏
页数:12
相关论文
共 36 条
[1]  
American Water Works Association, 2014, STAND DES PRESTR CON
[2]  
AWWA (American Water Works Association), 2018, CFRP Renewal and Strengthening of Prestressed Concrete Cylinder Pipe (PCCP), Standard C305
[3]   Mechanical properties and loading response of prestressed concrete cylinder pipes under internal water pressure [J].
Cheng, Bingqing ;
Dou, Tiesheng ;
Xia, Shifa ;
Zhao, Lijun ;
Yang, Jinxin ;
Zhang, Qi .
ENGINEERING STRUCTURES, 2020, 216
[4]  
[窦铁生 Dou Tiesheng], 2018, [水利学报, Journal of Hydraulic Engineering], V49, P207
[5]  
[窦铁生 Dou Tiesheng], 2017, [水利学报, Journal of Hydraulic Engineering], V48, P1438
[6]  
Ge S., 2015, Journal of Materials Science Research, V4, P59, DOI [10.5539/jmsr.v4n3p59, DOI 10.5539/JMSR.V4N3P59]
[7]   Failure Analysis, Condition Assessment Technologies, and Performance Prediction of Prestressed-Concrete Cylinder Pipe: State-of-the-Art Literature Review [J].
Ge, Shaoqing ;
Sinha, Sunil .
JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2014, 28 (03) :618-628
[8]  
Geisbush Jim, 2015, Proceedings of the Pipelines 2015 Conference. Recent Advances in Underground Pipeline Engineering and Construction, P1376
[9]  
Geisbush Jim, 2013, Pipelines 2013. Pipelines and Trenchless Construction and Renewals - a Global Perspective. Proceedings of the Pipelines 2013 Conference, P171
[10]  
Gipsov M., 2013, REHABILITATION LARGE, V2013, P220