A novel fully-automated method to measure steroids in serum by liquid chromatography-tandem mass spectrometry

被引:8
作者
Fraissinet, Francois [1 ]
Pereira, Tony [1 ]
Violin, Alizee [2 ]
Feugray, Guillaume [1 ,3 ]
Bach-Ngohou, Kalyane [2 ,4 ]
Brunel, Valery [1 ]
机构
[1] Rouen Univ Hosp, Dept Gen Biochem, F-76000 Rouen, France
[2] Nantes Univ, Dept Biol, Lab Biochem, CHU Nantes, F-44000 Nantes, France
[3] Normandie Univ, UNIROUEN, INSERM U1096, Rouen, France
[4] Nantes Univ, CHU Nantes, INSERM, Enter Nervous Syst Gut & Brain Disorders,IMAD, F-44000 Nantes, France
来源
JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB | 2023年 / 27卷
关键词
Radioimmunoassay; Liquid chromatography tandem mass; spectrometry; Automation; Testosterone; Steroids; CANDIDATE REFERENCE METHOD; TOTAL TESTOSTERONE; ANDROSTENEDIONE; QUANTIFICATION; PROFILE; PLASMA; ASSAY;
D O I
10.1016/j.jmsacl.2022.12.004
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Steroids play a key role in numerous physiological processes. Steroid determination is a useful tool to explore various endocrine diseases. Because of its specificity, mass spectrometry is considered to be a reference method for the determination of steroids in serum compared to radioimmunoassay. This technology could progress towards more automation for the optimal organization of clinical laboratories and ultimately for the benefit of patients.Methods: A fully automated ultra-high-performance liquid chromatography-tandem mass spectrometry method was developed and fully validated to determine five steroids in serum. Sample preparation was based on protein precipitation with filtration followed by online solid phase extraction. Chromatographic separation was performed using a biphenyl stationary phase.Results: The method was successfully validated according to European Medicine Agency guidelines. Coefficients of variation did not exceed, respectively, 8.4% and 8.1% for intra-and inter-assay precision. Method comparison with radioimmunoassay showed a proportional bias for all compounds, except for testosterone in men. Comparison with another LC-MS/MS method demonstrated acceptable concordance for all steroids, although a small bias was observed for androstenedione.Conclusion: The novelty of this method is that it has been fully automated. Automation provides benefits in traceability and allows significant savings in cost and time.
引用
收藏
页码:24 / 32
页数:9
相关论文
共 31 条
  • [1] refineR: A Novel Algorithm for Reference Interval Estimation from Real-World Data
    Ammer, Tatjana
    Schuetzenmeister, Andre
    Prokosch, Hans-Ulrich
    Rauh, Manfred
    Rank, Christopher M.
    Zierk, Jakob
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry Candidate Reference Method for Total Testosterone in Human Serum
    Botelho, Julianne Cook
    Shacklady, Christopher
    Cooper, Hans C.
    Tai, Susan S. -C.
    Van Uytfanghe, Katleen
    Thienpont, Linda M.
    Vesper, Hubert W.
    [J]. CLINICAL CHEMISTRY, 2013, 59 (02) : 372 - 380
  • [3] A Curious Case of Primary Amenorrhea
    Burns, Angela D.
    Taylor, Norman F.
    Taylor, David R.
    Bhake, Ragini C.
    Rahman, Faizanur
    [J]. CLINICAL CHEMISTRY, 2020, 66 (09) : 1150 - 1154
  • [4] Comparison of eight routine unpublished LC-MS/MS methods for the simultaneous measurement of testosterone and androstenedione in serum
    Buttler, Rahel M.
    Martens, Frans
    Ackermans, Mariette T.
    Davison, Andrew S.
    van Herwaarden, Antonius E.
    Kortz, Linda
    Krabbe, Johannes G.
    Lentjes, Eef G. W.
    Syme, Charlotte
    Webster, Rachel
    Blankenstein, Marinus A.
    Heijboer, Annemieke C.
    [J]. CLINICA CHIMICA ACTA, 2016, 454 : 112 - 118
  • [5] Impact of testosterone assay standardization efforts assessed via accuracy-based proficiency testing
    Cao, Zhimin
    Botelho, Julianne Cook
    Rej, Robert
    Vesper, Hubert
    Astles, J. Rex
    [J]. CLINICAL BIOCHEMISTRY, 2019, 68 : 37 - 43
  • [6] Simultaneous measurement of 18 steroids in human and mouse serum by liquid chromatography-mass spectrometry without derivatization to profile the classical and alternate pathways of androgen synthesis and metabolism
    Desai, Reena
    Harwood, D. Tim
    Handelsman, David J.
    [J]. CLINICAL MASS SPECTROMETRY, 2019, 11 : 42 - 51
  • [7] Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns containing phenyl moieties using principal component analysis
    Euerby, Melvin R.
    Petersson, Patrik
    Campbell, William
    Roe, Wendy
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) : 138 - 151
  • [8] European Medicine Agency, 2011, GUIDELINE BIOANALYTI
  • [9] Serum steroid profiling by isotopic dilution-liquid chromatography-mass spectrometry: Comparison with current immunoassays and reference intervals in healthy adults
    Fanelli, Flaminia
    Belluomo, Ilaria
    Di Lallo, Valentina D.
    Cuomo, Gaia
    De Iasio, Rosaria
    Baccini, Margherita
    Casadio, Elena
    Casetta, Bruno
    Vicennati, Valentina
    Gambineri, Alessandra
    Grossi, Gabriele
    Pasquali, Renato
    Pagotto, Uberto
    [J]. STEROIDS, 2011, 76 (03) : 244 - 253
  • [10] Fiet J, 2017, J ENDOCR SOC, V1, P186, DOI 10.1210/js.2016-1048