Reproducibility of Three-Dimensional Volumetric Measurement of Periocular Tumor Models

被引:2
作者
Fan, Wanlin [1 ]
Rokohl, Alexander C. [1 ,2 ]
Kupka, Patrick [1 ]
Hou, Xiaoyi [1 ]
Liu, Jinhua [1 ]
Li, Senmao [1 ]
Kopecky, Adam [3 ]
Ju, Sitong [1 ]
Matos, Philomena A. Wawer [1 ]
Guo, Yongwei [4 ,5 ]
Heindl, Ludwig M. [1 ,2 ]
机构
[1] Univ Cologne, Dept Ophthalmol, Fac Med, Kerpener Str 62, D-50937 Cologne, Germany
[2] Ctr Integrated Oncol CIO Aachen Bonn Cologne Duss, Cologne, Germany
[3] Univ Hosp Ostrava, Ophthalmol Clin, Ostrava, Czech Republic
[4] Zhejiang Univ, Affiliated Hosp 2, Eye Ctr, Sch Med, 88 Jiefang Rd, Hangzhou 310009, Peoples R China
[5] Zhejiang Prov Key Lab Ophthalmol, Hangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Reproducibility; Stereophotogrammetry; Three-dimensional; Tumor; Volume; BASAL-CELL CARCINOMA; AUSTRALIAN MOHS DATABASE; RELIABILITY; MALIGNANCIES; MANAGEMENT; ACCURACY; INVASION; SURGERY; SYSTEM; FACE;
D O I
10.1007/s40123-022-00595-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction In this study, we measured the volume of customized tumor models in the periocular area using three-dimensional (3D) stereophotogrammetry and evaluated the reproducibility of these measurements. Methods Five tumor models of different colors and sizes were placed in different periocular positions, and 3D facial images were obtained from 68 healthy adult volunteers. Subsequently, the volumes of the tumor models were measured, and the intra- and interrater reproducibility was assessed. Results The gray 6 mm model revealed the highest reliable measurements in both Caucasians (intra- and interrater intraclass correlation coefficients of 0.981 and 0.899, mean absolute difference of 1.446 and 3.327 mm(3), relative error measurement of 3.497% and 8.120%, technical error of measurement of 1.450 and 3.105 mm(3), and relative technical error of measurement of 3.506% and 7.580%) and Asians (0.968 and 0.844, 1.974 and 4.067 mm(3), 4.772% and 9.526%, 2.100 and 4.302 mm(3), and 5.076% and 10.076%, respectively). The highest reliability of measurements in the lateral upper eyelid (0.88 and 0.95, 4.042 and 3.626 mm(3), 9.730% and 9.020%, 5.714 and 3.358 mm(3), and 9.730% and 8.350%, respectively) and medial upper eyelid (0.81 and 0.89, 4.313 and 4.226 mm(3), 9.730% and 9.020%, 6.098 and 4.069 mm(3), and 9.730% and 8.350%, respectively) with eyes closed was evident in Caucasians, while the same trend (0.841 and 0.815, 2.828 and 3.757 mm(3), 9.860% and 9.840%, 4.052 and 4.308 mm(3), and 9.860% and 9.740%, respectively) was observed in Asians in the medial canthus with eyes closed. Conclusions This study confirms, for the first time, the high reliability of periocular tumor volume measurements using 3D stereophotogrammetry, suggesting its feasibility for eyelid tumor measurement. Further trials are required to investigate its clinical use for documentation and follow-up of different eyelid tumors.
引用
收藏
页码:111 / 123
页数:13
相关论文
共 49 条
[1]  
Arlette J P, 1998, J Cutan Med Surg, V2, P205
[2]   Clinical factors influencing periocular surgical defects after Mohs micrographic surgery [J].
Carter, KD ;
Nerad, JA ;
Whitaker, DC .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 15 (02) :83-91
[3]   Dermoscopy for the diagnosis of eyelid margin tumours [J].
Cinotti, E. ;
La Rocca, A. ;
Labeille, B. ;
Grivet, D. ;
Lambert, V. ;
Kaspi, M. ;
Nami, N. ;
Cambazard, F. ;
Fimiani, M. ;
Thuret, G. ;
Gain, P. ;
Tognetti, L. ;
Rubegni, P. ;
Perrot, J. L. .
BRITISH JOURNAL OF DERMATOLOGY, 2019, 181 (02) :397-398
[4]   Epidemiologic characteristics and clinical course of patients with malignant eyelid tumors in an incidence cohort in Olmsted County, Minnesota [J].
Cook, BE ;
Bartley, GB .
OPHTHALMOLOGY, 1999, 106 (04) :746-750
[5]   Treatment options and future prospects for the management of eyelid malignancies - An evidence-based update [J].
Cook, BE ;
Bartley, GB .
OPHTHALMOLOGY, 2001, 108 (11) :2088-2098
[6]  
Day Christian J, 2006, World J Orthod, V7, P15
[7]   Accuracy and reliability of 3D stereophotogrammetry: A comparison to direct anthropometry and 2D photogrammetry [J].
Dindaroglu, Furkan ;
Kutlu, Pinar ;
Duran, Gokhan Serhat ;
Gorgulu, Serkan ;
Aslan, Erhan .
ANGLE ORTHODONTIST, 2016, 86 (03) :487-494
[8]   Squamous cell carcinoma of the eyelids [J].
Donaldson, MJ ;
Sullivan, TJ ;
Whitehead, KJ ;
Williamson, RM .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (10) :1161-1165
[9]   Volume Measurement Using the Polhemus FastSCAN 3D Laser Scanning: A Novel Application for Burns Clinical Research [J].
Edgar, Dale ;
Day, Rob ;
Briffa, N. Kathy ;
Cole, Joan ;
Wood, Fiona .
JOURNAL OF BURN CARE & RESEARCH, 2008, 29 (06) :994-1000
[10]   Validation of the Portable Next-Generation VECTRA H2 3D Imaging System for Periocular Anthropometry [J].
Fan, Wanlin ;
Guo, Yongwei ;
Hou, Xiaoyi ;
Liu, Jinhua ;
Li, Senmao ;
Ju, Sitong ;
Matos, Philomena Alice Wawer ;
Simon, Michael ;
Rokohl, Alexander C. ;
Heindl, Ludwig M. .
FRONTIERS IN MEDICINE, 2022, 9