A Rapid, Simple, and Low-Blank Pumped Ion-Exchange Column Chromatography Technique for Boron Purification From Carbonate and Seawater Matrices

被引:3
|
作者
Xu, Chen [1 ]
Jurikova, Hana [1 ]
Nuber, Sophie [1 ,2 ,3 ]
Steele, Robert C. J. [1 ]
Trudgill, Molly [1 ,4 ]
Barker, Stephen [2 ]
Lear, Caroline H. [2 ]
Burke, Andrea [1 ]
Rae, James [1 ]
机构
[1] Univ St Andrews, Sch Earth & Environm Sci, St Andrews, Scotland
[2] Cardiff Univ, Sch Earth & Environm Sci, Cardiff, Wales
[3] Natl Taiwan Univ, Dept Geosci, Taipei, Taiwan
[4] Univ Paris Saclay, Lab Sci Climat & Environm, LSCE IPSL, CEA CNRS UVSQ, Gif Sur Yvette, France
基金
欧洲研究理事会;
关键词
boron isotope; column chromatography; boron purification; ICP-MS; ISOTOPE; PH; FRACTIONATION; SEPARATION; SEA;
D O I
10.1029/2023GC011228
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Boron isotope ratios (delta 11B) are used across the Earth Sciences and are increasing analyzed by Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS). Accurate delta 11B MC-ICPMS analysis requires boron purification from the sample matrix using ion-exchange column chromatography. However, the traditional gravity-drip column method is time-consuming and prone to airborne contamination due to its long duration and open resin surface. To address these issues, we designed a novel, simple, and reliable column chromatography technique called "peri-columns." This method uses a peristaltic pump to generate vacuum on a commonly used column set up. This method uses sealed collection beakers and does not require solutions to pass through pump tubing, minimizing contamination. The duration is reduced by eight-fold, processing 12 samples in just 1.5 hr. It also yields low and consistent total procedural blanks, averaging 11 pg. The efficiency and efficacy of this method were tested by repeated boron purification from calcium carbonate and high-sodium matrices with international and in-house reference materials. The results matched those obtained using the gravity column method and fell within our laboratory long-term and international certified values. The mean delta 11B and 2SD (standard deviation) of repeatedly processed NIST 8301f were 14.57 +/- 0.26 parts per thousand (n = 31), NIST 8301c was 24.19 +/- 0.33 parts per thousand (n = 10), STAiG-F1 was 16.20 +/- 0.26 parts per thousand (n = 13), and seawater was 39.52 +/- 0.32 parts per thousand (n = 10). All the components of our techniques are commercially available, and it is easily adaptable to other laboratories and isotope systems. Scientists use boron isotope ratios to study changes in seawater acidity, atmospheric carbon dioxide levels, pollution, and volatile cycling in the Earth. To measure these changes, they need to purify boron from a carbonate matrix, such as foraminifera and coral fossils or seawater, using ion-exchange column chromatography. However, the traditional gravity-drip column method is time-consuming and prone to airborne contamination. To address this issue, we developed a new technique called "peri-columns," where we connect manufactured columns to a peristaltic pump. The pump creates a vacuum, which pulls the liquid through columns faster than gravity. This new method is around eight times faster than the existing gravity method and, due to the shorter timescale and the closed nature of the columns, produces lower levels of contamination. We tested this technique using several international and in-house reference materials and found that it produced the same boron isotope ratio results as the traditional method but faster and cleaner. New peristaltic pump-based boron ion-exchange column chromatography achieving eight-fold faster boron separation This technique produces lower total procedure boron blanks than gravity columns
引用
收藏
页数:13
相关论文
共 11 条
  • [2] Rapid purification and monitoring of immunoglobulin M from ascites by perfusion ion-exchange chromatography
    McCarthy, E
    Vella, G
    Mhatre, R
    Lim, YP
    JOURNAL OF CHROMATOGRAPHY A, 1996, 743 (01) : 163 - 170
  • [3] Improved ion-exchange column chromatography for Cu purification from high-Na matrices and isotopic analysis by MC-ICPMS
    Kidder, James Andrew
    Voinot, Alexandre
    Sullivan, Kaj Vaughan
    Chipley, Donald
    Valentino, Marissa
    Layton-Matthews, Daniel
    Leybourne, Matthew
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (04) : 776 - 783
  • [4] RAPID PREPARATIVE-SCALE PURIFICATION OF PEPTIDES DERIVED FROM CASEINS USING MASS ION-EXCHANGE CHROMATOGRAPHY
    CHAPLIN, LC
    ANDREWS, AT
    JOURNAL OF CHROMATOGRAPHY, 1988, 450 (03): : 420 - 425
  • [5] RAPID PURIFICATION OF MONOCLONAL-ANTIBODY IN ASCITES BY HIGH-PERFORMANCE ION-EXCHANGE COLUMN CHROMATOGRAPHY FOR DIMINISHING NON-SPECIFIC STAINING
    TASAKA, K
    KOBAYASHI, M
    TANAKA, T
    INAGAKI, C
    ACTA HISTOCHEMICA ET CYTOCHEMICA, 1984, 17 (03) : 283 - 286
  • [6] RAPID AND SIMPLE PROCEDURE FOR THE PREPARATION OF HUMAN LACTATE DEHYDROGENASE-2 FROM ERYTHROCYTES USING AN ION-EXCHANGE MINI-COLUMN
    PETTIT, S
    NEALON, DA
    HENDERSON, AR
    CLINICA CHIMICA ACTA, 1980, 100 (01) : 59 - 63
  • [7] Purification of IgG from Sera of Rabbit and Guinea Pig by Flow-Through Mode Ion-Exchange Chromatography using DEAE Sepharose Fast Flow Column
    Ying Wang
    Peiyin Zhang
    Shujun Liu
    Yongsheng Zhang
    Tiesuo Zhao
    Wenhui Huang
    Chunyan He
    Yongli Yu
    Liying Wang
    Min Wan
    Chromatographia, 2011, 74 : 209 - 214
  • [8] Purification of IgG from Sera of Rabbit and Guinea Pig by Flow-Through Mode Ion-Exchange Chromatography using DEAE Sepharose Fast Flow Column
    Wang, Ying
    Zhang, Peiyin
    Liu, Shujun
    Zhang, Yongsheng
    Zhao, Tiesuo
    Huang, Wenhui
    He, Chunyan
    Yu, Yongli
    Wang, Liying
    Wan, Min
    CHROMATOGRAPHIA, 2011, 74 (3-4) : 209 - 214
  • [9] Ion-Exchange Sample Displacement Chromatography as a Method for Fast and Simple Isolation of Low- and High-Abundance Proteins from Complex Biological Mixtures
    Gajdosik, Martina Srajer
    Kovac, Spomenka
    Malatesti, Nela
    Mueller, Egbert
    Josic, Djuro
    FOOD TECHNOLOGY AND BIOTECHNOLOGY, 2014, 52 (01) : 58 - 63
  • [10] A simple and rapid technique for recovery of 99mTc from low specific activity (n,γ)99Mo based on solvent extraction and column chromatography
    Chattopadhyay, Sankha
    Das, Sujata Saha
    Barua, Luna
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (01) : 1 - 4