Bump deposition techniques for hybrid X-ray detectors

被引:3
作者
Schneider, Andreas [1 ]
Ghorbanian, Navid [1 ]
Osborn, Jack [1 ]
Cross, Simon P. [1 ]
Lipp, John D. [1 ]
French, Marcus J. [1 ]
机构
[1] Rutherford Appleton Lab RAL, Sci & Technol Facil Council STFC, Harwell Campus, Didcot OX11 0QX, England
来源
JOURNAL OF INSTRUMENTATION | 2023年 / 18卷 / 06期
关键词
Gamma detectors (scintillators; CZT; HPGe; HgI etc); Manufacturing; X-ray detectors;
D O I
10.1088/1748-0221/18/06/C06009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Flip-chip bonding is a common method for joining application-specific integrated circuits (ASIC) to pixel sensors in order to build hybrid radiation detectors for X-rays and gamma-rays. STFC-RAL is using two methods for the interconnects between ASIC and sensor pixels. These are either indium bumps which are deposited on ASIC and sensor prior to bonding or alternatively electrically conductive adhesive dots are printed on the sensor pixel array and flip-chip bonded to gold studs attached to each pixel of the ASIC. Conventionally the indium deposition is carried out on wafer-scale using a photolithographic lift-off process. Sensor and ASIC with indium bumps are singulated from wafers afterwards. Some sensor material (e.g. CdZnTe) which is required for high-energy and high-flux X-ray detectors at X-ray Free Electron Lasers (XFEL) or in other scientific experiments is only available as individual die instead of wafers. The stencil printing of conductive epoxy dots onto those sensor dies together with gold ball studding of ASICs is a suitable method for those dies. However, due to the size of printed epoxy dots this method has a limited pixel pitch and is currently only used for sensors with 250 gm-pitch or for larger pitch. A novel method for indium deposition was developed for such dies. A shadow mask with small apertures is optically aligned to the pixel array and mechanically clamped to the sensor die. After indium evaporation onto this assembly and after removal of the mask, indium bumps as small as 50 gm with a height of & SIM; 5 gm are deposit onto the pixel array of the sensor. The same is done for a matching ASIC. A comparison of these two methods indicates that indium bumps created by the shadow mask technique are approx. half the size of the epoxy dots and comparable with gold studs. Using this method, at present a pitch of 100 gm for those indium bumps can be achieved and development for further improvement towards smaller pitch is carried out currently. This novel indium deposition method is compared with the conventional wafer-scale indium lift-off method and the epoxy/gold stud flip-chip bonding in terms of interconnect quality, bond yield, and suitability for hybrid radiation detectors.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Interconnect and bonding techniques for pixelated X-ray and gamma-ray detectors
    Schneider, A.
    Veale, M. C.
    Duarte, D. D.
    Bell, S. J.
    Wilson, M. D.
    Lipp, J. D.
    Seller, P.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [2] Measuring the Quantum Efficiency of X-Ray Hybrid CMOS Detectors
    Colosimo, Joseph M.
    Falcone, Abraham D.
    Wages, Mitchell
    Hull, Samuel, V
    Burrows, David N.
    Range, Mitchell
    Hancock, Fredric
    Armstrong, Cole R.
    McCormick, Gooderham
    LaRocca, Daniel M.
    UV, X-RAY, AND GAMMA-RAY SPACE INSTRUMENTATION FOR ASTRONOMY XXII, 2021, 11821
  • [3] X-ray detectors for astrophysics
    Remillard, RA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2) : 285 - 291
  • [4] X-ray Peltier cooled detectors for X-ray fluorescence analysis
    Loupilov, A
    Sokolov, A
    Gostilo, V
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 463 - 464
  • [5] Characterizing Redlen CZT detectors for X-ray astronomy
    Pike, Sean N.
    Harrison, Fiona A.
    Burnham, Jill A.
    Cook, Walter W.
    Grefenstette, Brian W.
    Madsen, Kristin K.
    Miyasaka, Hiromasa
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY VIII, 2018, 10709
  • [6] X-ray detectors in medical imaging
    Spahn, Martin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 731 : 57 - 63
  • [7] Amorphous silicon X-ray detectors
    Hoheisel, M
    Arques, M
    Chabbal, J
    Chaussat, C
    Ducourant, T
    Hahm, G
    Horbaschek, H
    Schulz, R
    Spahn, M
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 1998, 227 : 1300 - 1305
  • [8] Dependence of x-ray sensitivity of direct conversion x-ray detectors on x-ray exposure and exposure history
    Kabir, MZ
    Yunus, M
    Kasap, SO
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 170 - 176
  • [9] Perspective of perovskite-based X-ray hybrid pixel array detectors
    Fiederle, Michael
    Baumbach, Tilo
    FRONTIERS IN PHYSICS, 2024, 12
  • [10] Hard X-ray and γ-ray detectors for the NeXT mission
    Takahashi, T
    Makishima, K
    Fukazawa, Y
    Kokubun, M
    Nakazawa, K
    Nomachi, M
    Tajima, H
    Tashiro, M
    Terada, Y
    NEW ASTRONOMY REVIEWS, 2004, 48 (1-4) : 269 - 273