Five-Year Clinical Outcomes After XIENCE PRIME Everolimus Elution Coronary Stent System (EECSS) Implantation

被引:0
|
作者
Shen, Rongrong [1 ,4 ]
Zhang, Peiyu [1 ]
Liu, Jing [1 ,2 ]
Guo, Rong [1 ]
Xu, Yawei [1 ,3 ]
机构
[1] Tongji Univ, Shanghai Peoples Hosp 10, Dept Cardiol, Sch Med, Shanghai 200072, Peoples R China
[2] Med Sch Shihezi Univ, Affiliated Hosp 1, Shihezi, Xinjiang, Peoples R China
[3] Tongji Univ, Pan Vasc Res Inst, Heart Lung & Blood Ctr, Shanghai, Peoples R China
[4] Tongji Univ, Shanghai Peoples Hosp 10, Dept Cardiol, Sch Med, 301 Yanchang Zhong Rd, Shanghai 200072, Peoples R China
关键词
major adverse cardiac events; major bleeding events; stent thrombosis; XIENCE PRIME Everolimus Elution Coronary Stent System; APPROVAL; SAFETY;
D O I
10.15212/CVIA.2023.0013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/aim: This study was aimed at evaluating 5-year effectiveness and safety in participants after XIENCE PRIME Everolimus Elution Coronary Stent System (EECSS) implantation. Materials and methods: From December 2013 to May 2014, 108 patients (127 lesions) were treated with the XIENCE PRIME EECSS. The entire follow-up included annual assessments for 5 years after treatment or until one of the clinical endpoints was reached. We evaluated the 5-year clinical outcomes with Kaplan-Meier analysis and the Cox regression model.Results: Nearly three-quarters of the participants were men (76.8%), and the average age was 65.6 +/- 10.8 years. Bifurcation lesions accounted for 96.1% (122 lesions), and left main lesions accounted for 3.9% (five lesions), with a total count of 127 lesions. The cumulative rate of major adverse cardiac events was as follows: 1 year, 1.9%; 2 year, 4.0%; and 5 year, 10.0%. No definite or probable stent thrombosis was observed, and the rate of target lesion failure was only 3.3% over 5 years. The cumulative rate of major bleeding eventually increased to only 4.4%.Conclusions: The 5-year clinical outcomes were favorable in patients treated with XIENCE PRIME EECSS, and the incidence of stent thrombosis and target lesion failure was relatively low. The incidence of major bleeding gradually increased but remained moderate.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [31] Comparison of Everolimus- and Paclitaxel-Eluting Stents in Patients With Acute and Stable Coronary Syndromes Pooled Results From the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) Trials
    Planer, David
    Smits, Pieter C.
    Kereiakes, Dean J.
    Kedhi, Elvin
    Fahy, Martin
    Xu, Ke
    Serruys, Patrick W.
    Stone, Gregg W.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (10) : 1104 - 1115
  • [32] The efficacy of everolimus-eluting stent implantation in patients with ST-segment elevation myocardial infarction: outcomes of 2-year clinical follow-up
    Hideki Yano
    Shigeo Horinaka
    Mayuko Ishikawa
    Toshihiko Ishimitsu
    Heart and Vessels, 2016, 31 : 1609 - 1615
  • [33] The efficacy of everolimus-eluting stent implantation in patients with ST-segment elevation myocardial infarction: outcomes of 2-year clinical follow-up
    Yano, Hideki
    Horinaka, Shigeo
    Ishikawa, Mayuko
    Ishimitsu, Toshihiko
    HEART AND VESSELS, 2016, 31 (10) : 1609 - 1615
  • [34] Impact of Dual Antiplatelet Therapy Beyond 1 Year on Clinical Outcomes of Patients With Stent Fracture or Peri-Stent Contrast Staining After Sirolimus-Eluting Stent Implantation
    Fuku, Yasushi
    Kadota, Kazushige
    Amano, Hidewo
    Kubo, Shunsuke
    Otsuru, Suguru
    Habara, Seiji
    Tada, Takeshi
    Tanaka, Hiroyuki
    Goto, Tsuyoshi
    CIRCULATION JOURNAL, 2018, 82 (01) : 211 - +
  • [35] The relationship between coronary stent strut thickness and the incidences of clinical outcomes after drug-eluting stent implantation: A systematic review and meta-regression analysis
    Saito, Akira
    Dai, Zhehao
    Ono, Masafumi
    Kanie, Takayoshi
    Takaoka, Yoshimitsu
    Mizuno, Atsushi
    Komiyama, Nobuyuki
    Asano, Taku
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (03) : 575 - 582
  • [36] Assessment of the LDL-C/HDL-C ratio as a predictor of one year clinical outcomes in patients with acute coronary syndromes after percutaneous coronary intervention and drug-eluting stent implantation
    Zhixiong Zhong
    Jingyuan Hou
    Qifeng Zhang
    Wei Zhong
    Bin Li
    Cunren Li
    Zhidong Liu
    Min Yang
    Pingsen Zhao
    Lipids in Health and Disease, 18
  • [37] Assessment of the LDL-C/HDL-C ratio as a predictor of one year clinical outcomes in patients with acute coronary syndromes after percutaneous coronary intervention and drug-eluting stent implantation
    Zhong, Zhixiong
    Hou, Jingyuan
    Zhang, Qifeng
    Zhong, Wei
    Li, Bin
    Li, Cunren
    Liu, Zhidong
    Yang, Min
    Zhao, Pingsen
    LIPIDS IN HEALTH AND DISEASE, 2019, 18 (1)
  • [38] Impact of stent size on angiographic and clinical outcomes after implantation of everolimus-eluting bioresorbable scaffolds in daily practice: insights from the ISAR-ABSORB registry
    Wiebe, Jens
    Hoppmann, Petra
    Kufner, Sebastian
    Harada, Yukinori
    Colleran, Roisin
    Michel, Jonathan
    Giacoppo, Daniele
    Schneider, Simon
    Cassese, Salvatore
    Ibrahim, Tareq
    Schunkert, Heribert
    Laugwitz, Karl-Ludwig
    Kastrati, Adnan
    Byrne, Robert A.
    EUROINTERVENTION, 2016, 12 (02) : E137 - E143
  • [39] The Impact of Patient and Lesion Complexity on Clinical and Angiographic Outcomes After Revascularization With Zotarolimus- and Everolimus-Eluting Stents A Substudy of the RESOLUTE All Comers Trial (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention)
    Stefanini, Giulio G.
    Serruys, Patrick W.
    Silber, Sigmund
    Khattab, Ahmed A.
    van Geuns, Robert J.
    Richardt, Gert
    Buszman, Pawel E.
    Kelbaek, Henning
    van Boven, Adrianus J.
    Hofma, Sjoerd H.
    Linke, Axel
    Klauss, Volker
    Wijns, William
    Macaya, Carlos
    Garot, Philippe
    Di Mario, Carlo
    Manoharan, Ganesh
    Kornowski, Ran
    Ischinger, Thomas
    Bartorelli, Antonio L.
    Gobbens, Pierre
    Windecker, Stephan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (22) : 2221 - 2232
  • [40] Final five-year outcomes after implantation of biodegradable polymer-coated biolimus-eluting stents versus durable polymer-coated sirolimus-eluting stents
    Jakobsen, Lars
    Christiansen, Evald H.
    Maeng, Michael
    Hansen, Knud N.
    Kristensen, Steen D.
    Botker, Hans E.
    Terkelsen, Christian J.
    Jensen, Svend E.
    Raungaard, Bent
    Madsen, Morten
    Lassen, Jens F.
    Jensen, Lisette O.
    EUROINTERVENTION, 2017, 13 (11) : 1337 - 1345