Enhancing the performance of a solar air heater by employing the broken V-shaped ribs

被引:5
|
作者
Rajendran, Vijayakumar [1 ]
Vikram, Muthuraman Ponrajan [2 ]
Kim, Sung Chul [3 ]
Gullo, Paride [4 ]
Alodhayb, Abdullah [5 ]
Pandiaraj, Saravanan [6 ]
Prabakaran, Rajendran [3 ]
机构
[1] Natl Engn Coll, Dept Mech Engn, KR Nagar, Kovilpatti 628503, Tamilnadu, India
[2] SIMATS, Inst Mech Engn, Saveetha Sch Engn, Chennai 602105, India
[3] Yeungnam Univ, Sch Mech Engn, 280 Daehak Ro, Gyongsan 712749, Gyeongbuk, South Korea
[4] Univ Southern Denmark SDU, Dept Mech & Elect Engn, Als 2, DK-6400 Sonderborg, Denmark
[5] King Saud Univ, Coll Sci, Dept Phys & Astron, POB 2455, Riyadh 11451, Saudi Arabia
[6] King Saud Univ, Dept Basic Sci & Selfdev skills, CFY Deanship, POB 2455, Riyadh 11451, Saudi Arabia
关键词
Solar energy; Air heaters; Surface modification; Baffles; Thermal efficiency; THERMAL PERFORMANCE; THERMOHYDRAULIC PERFORMANCE; TRANSFER ENHANCEMENT; RECTANGULAR DUCT; TRANSVERSE RIBS; CFD ANALYSIS; FLUID-FLOW;
D O I
10.1007/s11356-023-27814-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work aims to enhance the performance of a solar air heater (SAH) by introducing broken V-ribs as roughness elements on the absorber plate. The unit with a conventional flat absorber plate is referred to as the "FSAH," while the unit with a broken V-rib-shaped absorber plate is called the "VSAH." The experiment was performed for three air velocities: 25 m/s, 20 m/s, and 15 m/s and the corresponding air flow rates were 0.037 kg/s, 0.031 kg/s, and 0.023 kg/s, respectively. The results showed that the maximum temperature was experienced on the absorber plate, followed by the glass plate for both SAHs. Overall, the average absorber and glass plate temperatures of the VSAH were 0.6-1.4 degrees C and 0.4-1.9 degrees C lower than those of the FSAH. Compared to the FSAH, the experimental results showed that the VSAH experienced useful power and thermal efficiency that were 16.6-19.8% and 15.7-20.4% higher, respectively, while the top surface heat losses were found to decrease by 2.1-8.1%. Due to the disrupted air paths in the VSAH, the observed pressure drop was 113.3-133.3% higher than that of the FSAH. More impotently, the thermo-hydraulic performance factor was always higher 1 and the observed values were 1.48, 1.39, and 1.24 at the v(a) (velocity) values of 15, 20, and 25 m/s, respectively. Therefore, the proposed VSAH had an admirable thermal performance as compared to FSAH. Further, optimization through varying the roughness parameters, namely, relative blockage width (W/w), relative pitch ratio (P/e), number of baffles (n), relative blockage height (e/H), and angle of attack (beta) could helped to achieve better performance.
引用
收藏
页码:77807 / 77818
页数:12
相关论文
共 50 条
  • [21] Optimization of the Structure of a Solar Air Heater Fitted with V-Shaped Perforated Baffles
    Zhuang, Chunlong
    Fu, Boheng
    Huang, Guangqing
    Zhang, Hongyu
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2016, 34 (04) : 604 - 610
  • [22] Performance optimization of solar air heater using inclined ribs
    Fattoum, Raoua
    Hidouri, Ammar
    Attia, Mohammed El Hadi
    Arici, Muesluem
    Abbassi, Mohamed Ammar
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (17) : 9013 - 9025
  • [23] Performance study of solar air heater duct with gap in V-rib with symmetrical gap and staggered ribs
    Patel, Sumer Singh
    Lanjewar, Atul
    HEAT AND MASS TRANSFER, 2019, 55 (09) : 2517 - 2532
  • [24] Experimental Analysis of a Solar Air Heater Featuring Multiple Spiral-Shaped Semi-Conical Ribs
    Shankar, Ravi
    Kumar, Rajeev
    Pandey, Arun Kumar
    Thakur, Deep Singh
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (03):
  • [25] Performance analysis of solar air heater duct roughened with multigap V-down ribs combined with staggered ribs
    Deo, Narinderpal Singh
    Chander, Subhash
    Saini, J. S.
    RENEWABLE ENERGY, 2016, 91 : 484 - 500
  • [26] Performance Investigation of a Solar Air Heater Artificially Roughened With Joukowski Airfoil Ribs
    Roy, Bibhrat
    Reddy, Desireddy Shashidhar
    Khan, Mohd. Kaleem
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (01):
  • [27] Nusselt number and friction characteristics of solar air heater roughened with novel twisted V-shaped staggered ribs using liquid crystal thermography
    Kumar, Dheeraj
    Layek, Apurba
    RENEWABLE ENERGY, 2022, 201 : 651 - 666
  • [28] Exergetic performance analysis of solar air heater with inverted L-shape ribs as roughness element
    Chaudhari, Manmohan
    Sharma, Sohan lal
    Debbarma, Ajoy
    ARCHIVES OF THERMODYNAMICS, 2023, 44 (03) : 241 - 267
  • [29] Performance assessment of double-pass parallel flow solar air heater with perforated multi-V ribs roughness - Part B
    Singh, Varun Pratap
    Jain, Siddharth
    Gupta, Jml
    EXPERIMENTAL HEAT TRANSFER, 2022, 35 (07) : 1059 - 1076
  • [30] Effect of gap width on thermal performance of solar air heater having arc-shaped ribs with symmetrical gaps: an experimental investigation
    Jain, Sheetal Kumar
    Misra, Rohit
    Das Agrawal, Ghanshyam
    ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2020, 22 (07) : 6563 - 6583