Test-retest repeatability of electrically evoked isotonic power and isometric torque in the plantar flexors

被引:2
|
作者
Paris, Michael T. [1 ]
Zero, Alexander M. [1 ]
Rice, Charles L. [1 ,2 ]
机构
[1] Univ Western Ontario, Sch Kinesiol, Fac Hlth Sci, London, ON N6A 3K7, Canada
[2] Univ Western Ontario, Schulich Sch Med & Dent, Dept Anat & Cell Biol, London, ON N6A 3K7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
dynamic contraction; muscle power; tetanic contraction; stimulated contraction; LOW-FREQUENCY FATIGUE; SKELETAL-MUSCLE; MAXIMAL VOLUNTARY; RELIABILITY; REPRODUCIBILITY;
D O I
10.1139/apnm-2022-0348
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Electrically evoked isometric torque has good to excellent repeatability, but the degree of repeatability for electrically evoked isotonic power is unknown. We evaluated the test-retest repeatability of plantar flexion isometric torque and isotonic power evoked using brief tetanic trains at 10 and 50 Hz. Both torque and power had excellent (intraclass correlation coefficient >0.9) repeatability at low and high frequencies. Similar to isometric torque, electrically evoked isotonic power is a stable measure for studying dynamic muscle function.
引用
收藏
页码:91 / 95
页数:5
相关论文
共 50 条
  • [41] Test-Retest Reliability of Resting-State Magnetoencephalography Power in Sensor and Source Space
    Martin-Buro, Maria Carmen
    Garces, Pilar
    Maestu, Fernando
    HUMAN BRAIN MAPPING, 2016, 37 (01) : 179 - 190
  • [42] Inter-day test-retest reliability and feasibility of isokinetic, isometric, and isotonic measurements to assess quadriceps endurance in people with chronic obstructive pulmonary disease: A multicenter study
    Frykholm, Erik
    Gephine, Sarah
    Saey, Didier
    van Hees, Hieronymus
    Lemson, Arthur
    Klijn, Peter
    Maltais, Francois
    Nyberg, Andre
    CHRONIC RESPIRATORY DISEASE, 2018, 16
  • [43] Test-Retest Reliability of Low-Level Evoked Distortion Product Otoacoustic Emissions
    Stuart, Andrew
    Passmore, Amy L.
    Culbertson, Deborah S.
    Jones, Sherri M.
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2009, 52 (03): : 671 - 681
  • [44] Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke
    Mentiplay, Benjamin F.
    Tan, Dawn
    Williams, Gavin
    Adair, Brooke
    Pua, Yong-Hao
    Bower, Kelly J.
    Clark, Ross A.
    JOURNAL OF BIOMECHANICS, 2018, 75 : 171 - 175
  • [45] Test-retest reliability of binaural simultaneous cervical vestibular evoked myogenic potential recording
    Lee, Min Young
    Yi, Yeo-Jeen
    Park, Hanaro
    Kim, Mi Hee
    Lee, Jun Ho
    Oh, Seung-Ha
    Suh, Myung-Whan
    JOURNAL OF VESTIBULAR RESEARCH-EQUILIBRIUM & ORIENTATION, 2015, 25 (3-4): : 151 - 160
  • [46] Test-retest repeatability and reproducibility of ADC measures by breast DWI: Results from the ACRIN 6698 trial
    Newitt, David C.
    Zhang, Zheng
    Gibbs, Jessica E.
    Partridge, Savannah C.
    Chenevert, Thomas L.
    Rosen, Mark A.
    Bolan, Patrick J.
    Marques, Helga S.
    Aliu, Sheye
    Li, Wen
    Cimino, Lisa
    Joe, Bonnie N.
    Umphrey, Heidi
    Ojeda-Fournier, Haydee
    Dogan, Basak
    Oh, Karen
    Abe, Hiroyuki
    Drukteinis, Jennifer
    Esserman, Laura J.
    Hylton, Nola M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (06) : 1617 - 1628
  • [47] Tender or not tender:: Test-retest repeatability of pressure pain thresholds in the trapezius and deltoid muscles of healthy women
    Persson, AL
    Brogårdh, C
    Sjölund, BH
    JOURNAL OF REHABILITATION MEDICINE, 2004, 36 (01) : 17 - 27
  • [48] Test-retest reliability of an insole plantar pressure system to assess gait along linear and curved trajectories
    Godi, Marco
    Turcato, Anna Maria
    Schieppati, Marco
    Nardone, Antonio
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
  • [49] Test-retest reliability of knee extensor rate of velocity and power development in older adults using the isotonic mode on a Biodex System 3 dynamometer
    Van Driessche, Stijn
    Van Roie, Evelien
    Vanwanseele, Benedicte
    Delecluse, Christophe
    PLOS ONE, 2018, 13 (05):
  • [50] Test-retest repeatability reveals a temporal kinematic signature for an upper limb precision grasping task in adults
    Niechwiej-Szwedo, Ewa
    Nouredanesh, Mina
    Tung, James
    HUMAN MOVEMENT SCIENCE, 2021, 75