Fiberscope-Based Measurement of Coaptation Height for Intraoperative Assessment of Mitral Valve Repair

被引:2
|
作者
Recco, Dominic P. [1 ,2 ]
Kneier, Nicholas E. [1 ]
Earley, Patrick D. [1 ]
Kizilski, Shannen B. [1 ,2 ]
Hammer, Peter E. [1 ,2 ]
Hoganson, David M. [1 ,2 ,3 ]
机构
[1] Boston Childrens Hosp, Dept Cardiac Surg, Boston, MA USA
[2] Harvard Med Sch, Boston, MA USA
[3] Boston Childrens Hosp, Dept Cardiac Surg, 300 Longwood Ave,Bader,2nd Floor, Boston, MA 02215 USA
关键词
mitral valve; mitral regurgitation; mitral valve coaptation; coaptation height; coaptation measurement; congenital valve disease; SYSTOLIC ANTERIOR MOTION; REGURGITATION; REPLACEMENT; SURGERY; RECONSTRUCTION; ANNULOPLASTY; DURABILITY; MANAGEMENT; EVOLUTION; POSTERIOR;
D O I
10.1177/21501351231221459
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Restoring adequate coaptation height is a key principle of mitral valve (MV) repair. This study aimed to evaluate the utility of fiberscope (FS) technology to assess MV coaptation height for intraoperative use.Methods Ex-vivo testing was performed on five adult porcine hearts. The left atrium (LA) was resected, and the left ventricle (LV) was pressurized retrograde to 27 +/- 1mm Hg. An endoscope was inserted into the LV apex, centered under the MV orifice. An FS system (Milliscope II camera, LED light source, and 0.7 mm diameter x 15 cm long) 90 degrees semirigid scope with 1.2 mm focal length) was mounted above the MV annulus in a custom alignment and measuring fixture. Three blinded measurements were taken at two locations on each MV, A2 and P2 segment, from the top of coaptation to the leaflet edge identified by the FS. Accurate positioning was verified using the LV endoscope. A control (metal rod of similar thickness) was used for comparison, with coaptation height recorded when the control was seen via the endoscope.Results Coaptation heights were similar for the control and FS methods across all hearts at A2 (11.6 +/- 2.6 mm control vs 11.8 +/- 2.2 mm FS) and P2 (13.3 +/- 2.6 mm control vs 13.4 +/- 2.9 mm FS) segments, with similar measurement variability (control SD 0.1-1.0 mm; FS SD 0.1-0.9 mm). One outlier was excluded from analysis (n = 19/20). The maximum absolute difference and percent error between measurement methods were less than 1.1 mm (median [IQR], 0.6 [0.3-0.9] mm) and less than 14% (4.1 [2.2-7.6]%).Conclusions Utilization of a miniaturized FS enabled precise and accurate quantification of MV coaptation. This technique is promising for evaluating post-repair valve competence and coaptation height.
引用
收藏
页码:371 / 379
页数:9
相关论文
共 50 条
  • [41] Quantitative Assessment of Changes in Left Ventricular Shape following Mitral Valve Repair
    Maffessanti, F.
    Tamborini, G.
    Muratori, M.
    Zanobini, M.
    Mor-Avi, V.
    Sugeng, L.
    Alamanni, F.
    Lang, R. M.
    Pepi, M.
    Caiani, E. G.
    CINC: 2009 36TH ANNUAL COMPUTERS IN CARDIOLOGY CONFERENCE, 2009, 36 : 33 - +
  • [42] Modified Intraoperative Saline Injection Leak Test to Assess Mitral Valve Repair
    Abbasi, Mohammad
    Maleki, Mahmood Hosseinzadeh
    Javan, Hadi
    Amouzeshi, Ahmad
    Moeinipour, Ali Asghar
    Shamloo, Alireza Sepehri
    Zirak, Nahid
    IRANIAN HEART JOURNAL, 2012, 13 (02): : 20 - 23
  • [43] Catheter-Based Edge-to-Edge Mitral Valve Repair After Percutaneous Mitral Valve Annuloplasty Failure
    Grasso, Carmelo
    Attizzani, Guilherme F.
    Ohno, Yohei
    Dipasqua, Fabio
    Mangiafico, Sarah
    Ministeri, Margherita
    Caggegi, Anna
    Cannata, Stefano
    Scandura, Salvatore
    Tamburino, Corrado
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (07) : E85 - E86
  • [44] Systolic Anterior Motion (SAM) Complicating Mitral Valve Repair: Current Concepts of Intraoperative and Postoperative Management
    Nenna, Antonio
    Lusini, Mario
    Barberi, Filippo
    Greco, Salvatore Matteo
    Chello, Massimo
    Nappi, Francesco
    Spadaccio, Cristiano
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 37
  • [45] Surgical mitral valve repair technique considerations based on the available evidence
    Can, Tolga
    Kirov, Hristo
    Caldonazo, Tulio
    Mukharyamov, Murat
    Faerber, Gloria
    Doenst, Torsten
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 30 (02): : 302 - 316
  • [46] Image-based modelling and numerical simulations of the Cardioband? procedure for mitral valve regurgitation repair
    Gasparotti, Emanuele
    Vignali, Emanuele
    Mariani, Massimiliano
    Berti, Sergio
    Celi, Simona
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2022, 394
  • [47] Normalization of Mitral Annular Motion after Repair of Mitral Valve Prolapse: Geometric Quantification Using Intraoperative 3D TEE
    Chen, Tien-En
    Suri, Rakesh M.
    Enriquez-Sarano, Maurice
    Michelena, Hector I.
    Burkhart, Harold M.
    Gillespie, Shane M.
    Hayward, Geoffrey L.
    Mankad, Sunil V.
    CIRCULATION, 2012, 126 (21)
  • [48] Flow-dynamics assessment of mitral-valve surgery by intraoperative vector flow mapping
    Akiyama, Koichi
    Nakamura, Naotoshi
    Itatani, Keiichi
    Naito, Yoshifumi
    Kinoshita, Mao
    Shimizu, Masaru
    Hamaoka, Saeko
    Kato, Hideya
    Yasumoto, Hiroaki
    Nakajima, Yasufumi
    Mizobe, Toshiki
    Numata, Satoshi
    Yaku, Hitoshi
    Sawa, Teiji
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (06) : 869 - 875
  • [49] iVAC-2L to Facilitate Transcatheter Edge-to-Edge Repair of Mitral Valve Without Leaflet Coaptation
    Sacha, Jerzy
    Milejski, Wojciech
    Bugajski, Jaros law
    Pidzik, Natalia
    Pawlowski, Tomasz
    Gierlotka, Marek
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (18) : 2327 - 2328
  • [50] Surgical and Transcatheter Mitral Valve Repair for Severe Chronic Mitral Regurgitation: A Review of Clinical Indications and Patient Assessment
    Vesely, Mark R.
    Benitez, Michael
    Robinson, Shawn W.
    Collins, Julia A.
    Dawood, Murtaza Y.
    Gammie, James S.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2015, 4 (12):