Study of the Detection Method of Series AC Arc Faults Based on High-frequency Zero-sequence Current Coupling Signal

被引:1
|
作者
He, Zhipeng [1 ]
Zhang, Yezhen [1 ]
Li, Weilin [1 ]
Zhao, Hu [1 ]
Li, Bingqiang [1 ]
机构
[1] Northwestern Polytech Univ, Sch Automat, Xian, Peoples R China
关键词
Arc fault; detection method; characteristics; high-frequency zero-sequence current;
D O I
10.1109/HOLM56075.2023.10352218
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Arc fault is one of the main causes of electrical fire hazards. Most research is mainly based on current signals to detect arc faults. However, load type and other factors easily affect the current signal, which easily causes missed judgment and misjudgment of switches. To solve this issue, this paper proposes a detection method based on the high-frequency zero-sequence current coupling signal for low-voltage series AC arc faults. First, an experimental platform was built for low-voltage series AC arc fault according to the IEC 62606 standard, and the high-frequency zero-sequence current coupling signal of ten typical loads under different line conditions was collected. Then, the characteristics of zero-sequence current under different loads and line conditions were analyzed, and the arc fault detection algorithm was developed according to the different characteristics of the line's normal and arc-fault states. Finally, the effectiveness, stability, and applicability of the arc fault detection method were verified by various experimental conditions with a prototype. The result shows that the detection accuracy of the presented method is about 98%, which has a certain guiding significance for the development of arc fault detection devices.
引用
收藏
页码:186 / 193
页数:8
相关论文
共 50 条
  • [31] High-frequency Arc Fault Detection in Circuit Breaker in Substation AC Filter Branch
    Wang B.
    Wei X.
    Zhang G.
    Feng Y.
    Wen B.
    Dong X.
    1837, Chinese Society for Electrical Engineering (38): : 1837 - 1845
  • [32] Fault detection method for unbalanced distribution networks based on flexible regulation of zero-sequence voltage
    Zhang W.
    Wang L.
    Xue Y.
    Xu B.
    Wang C.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (11): : 159 - 169
  • [33] High-impedance faulty feeder detection for cross-country faults in distribution networks based on zero-sequence active power regulation
    Lan, Yuting
    Yu, Kun
    Zeng, Xiangjun
    Cai, Rong
    Deng, Qingbo
    Wu, Chenyu
    He, Shigeng
    Xu, Shijie
    Jia, Youcheng
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 162
  • [34] Initial Rotor Position Detection for Brushless DC Motors Based on Coupling Injection of High-Frequency Signal
    Chen, Wei
    Dong, Shuhai
    Li, Xinmin
    Cao, Yanfei
    Zhang, Guozheng
    IEEE ACCESS, 2019, 7 : 133433 - 133441
  • [35] Single-phase grounding fault line selection method based on zero-sequence current increment
    Hao, Bai
    ENERGY REPORTS, 2022, 8 : 305 - 312
  • [36] The arc fault detection based on the current signal short time zero crossing rate
    Liu, Xiaoming
    Xu, Yefei
    Liu, Ting
    Yu, Fangyu
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 (13): : 125 - 133
  • [37] High-Resistance Connection Detection in Permanent Magnet Synchronous Machine Using Zero-Sequence Current Component
    Hang, Jun
    Zhang, Jianzhong
    Cheng, Ming
    Zhang, Bangfu
    Ding, Shichuan
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (07) : 4710 - 4719
  • [38] Faulty Feeder Detection in Small Current Grounding System Based on Complete Waveform Recognition of Zero-sequence Signals
    Yuan J.
    Jiao Z.
    Dianwang Jishu/Power System Technology, 2024, 48 (02): : 839 - 850
  • [39] Detection of the faulted network element using frequency spectrum features of zero-sequence current under transient earth faults in the network with neutral grounding through Peterson-coil
    Moldovanova, E. A.
    Vainshtein, R. A.
    Shestakova, V. V.
    2016 THIRD INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, COMPUTER ENGINEERING AND THEIR APPLICATIONS (EECEA), 2016, : 93 - 97
  • [40] Series AC Arc Fault Detection Method Based on Hybrid Time and Frequency Analysis and Fully Connected Neural Network
    Wang, Yangkun
    Zhang, Feng
    Zhang, Xueheng
    Zhang, Shiwen
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2019, 15 (12) : 6210 - 6219