Transverse isotropic compression behavior of aligned steel fiber UHPC produced by electromagnetic field

被引:9
|
作者
Xiong, Yongming [1 ]
Yang, Ming [1 ]
Zhao, Jiankai [1 ,2 ]
Yuan, Yan [1 ]
Liu, Yan [1 ]
Shi, Heng [1 ,3 ]
机构
[1] Southeast Univ, Sch Transportat, Nanjing, Peoples R China
[2] Highway Bur, Dept Transportat Sichuan Prov, Chengdu, Peoples R China
[3] Suzhou Commun Investment Mat Co Ltd, Suzhou, Peoples R China
关键词
Aligned steel fiber ultra-high performance; concrete (ASF-UHPC); Steel fiber; Fiber orientation; Magnetic field; Transverse isotropy; Compressive behavior; REINFORCED CONCRETE; MECHANICAL-PROPERTIES; FLEXURAL BEHAVIOR; CEMENT MORTAR; ORIENTATION; PERFORMANCE;
D O I
10.1016/j.conbuildmat.2023.134579
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Aligned steel fiber ultra-high performance concrete (ASF-UHPC) demonstrates transverse isotropic mechanical properties. Specifically, when subjected to compressive stress perpendicular to the fiber orientation, surface cracks emerge proximate to the fiber tips, resulting in a significant enhancement of the material's compressive strength. Conversely, under compressive stress applied parallel to the fiber direction, fissures manifest along the fiber orientation, leading to a notable reduction in compressive strength. Consequently, the primary contributory factor underlying augmented compressive strength is the lateral restraint effectuated by the fibers. The optimization of fiber distribution for the aim of altering compressive strength is subject to the influence of the qualities of the UHPC matrix. Moreover, a comprehensive analysis extends to the examination of pertinent parameters, encompassing fiber volume fractions, fiber lengths, and fiber shapes. Investigation of these facets reveals an optimal range of fiber volume fraction, approximately 1.0% to 1.5%, which imparts maximal compressive strength in ASF-UHPC subjected to compressive stress perpendicular to the fiber orientation. When forces are applied parallel to the fiber direction, the incorporation of longer fibers or hooked-end fibers mitigates the reduction in compressive strength perpendicular to the applied stress. The consideration of the transverse mechanical attributes exhibited by aligned steel fibers, coupled with the optimization of fiber distribution characteristics, not only attenuates steel fiber consumption but also underscores a sustainable approach by curtailing CO2 emissions.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Investigation of shear response due to variation of fiber volume fraction, transverse steel, and placement method on short span R/UHPC beams
    Frank, Timothy
    Amaddio, Peter
    Landes, Cole
    Farrell, Darcy
    Decko, Elizabeth
    Tri, Alexis
    ADVANCES IN STRUCTURAL ENGINEERING, 2024, 27 (10) : 1762 - 1776
  • [22] Behavior of Rectangular-Sectional Steel Tubular Columns Filled with High-Strength Steel Fiber Reinforced Concrete Under Axial Compression
    Liu, Shiming
    Ding, Xinxin
    Li, Xiaoke
    Liu, Yongjian
    Zhao, Shunbo
    MATERIALS, 2019, 12 (17)
  • [23] Microstructural evolution and strengthening mechanism of aligned steel fiber cement-based tail backfills exposed to electromagnetic induction
    Li, Xihao
    Cao, Shuai
    Yilmaz, Erol
    INTERNATIONAL JOURNAL OF MINERALS METALLURGY AND MATERIALS, 2024, 31 (11) : 2390 - 2403
  • [24] Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
    Mu, Ru
    Wei, Luansu
    Wang, Xiaowei
    Li, Hui
    Qing, Longbang
    Zhou, Jian
    Zhao, Quanming
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (136):
  • [25] Pullout Behavior of Straight Steel Fiber Reinforced UHPC Subjected to Single Cryogenic to Elevated Cycle
    He, Bei
    Zhang, Hongen
    Zhu, Xinping
    Jiang, Zhengwu
    SMART & SUSTAINABLE INFRASTRUCTURE: BUILDING A GREENER TOMORROW, ISSSI 2023, 2024, 48 : 779 - 784
  • [26] Experimental Study on Seismic Behavior of UHPC Columns with Different Stirrup Ratios and Steel Fiber Contents
    Hu R.
    Fang Z.
    Xu B.-D.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2021, 34 (08): : 65 - 77
  • [27] Effect of steel-polypropylene hybrid fiber and coarse aggregate inclusion on the stress-strain behavior of ultra-high performance concrete under uniaxial compression
    Deng, Fangqian
    Xu, Lihua
    Chi, Yin
    Wu, Fanghong
    Chen, Qian
    COMPOSITE STRUCTURES, 2020, 252
  • [28] Electromagnetic method field test for characterizing steel fibers in ultra-high performance concrete (UHPC)
    Alabi, Daniel J.
    Voss, Megan
    Ferraro, Christopher C.
    Riding, Kyle
    Harley, Joel B.
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 374
  • [29] Behavior of unconfined steel-fiber reinforced UHPC post high-temperature exposure
    Agrawal, Sohit
    Yulianti, Erika
    Amran, Mugahed
    Hung, Chung-Chan
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2025, 22
  • [30] Preparation of Aligned Steel-Fiber-Reinforced Concrete Using a Magnetic Field Created by the Assembly of Magnetic Pieces
    Mu, Ru
    Dong, Ruixin
    Liu, Haoqi
    Chen, Haoyu
    Cheng, Qingao
    Fan, Chunhao
    CRYSTALS, 2021, 11 (07)