Multivariate Optimization and Validation of a Modified QuEChERS Method for Determination of PAHs and PCBs in Grilled Meat by GC-MS

被引:7
作者
Ostadgholami, Mahsa [1 ]
Zeeb, Mohsen [1 ]
Amirahmadi, Maryam [2 ,3 ]
Daraei, Bahram [4 ]
机构
[1] Islamic Azad Univ, Fac Sci, Dept Appl Chem, South Tehran Branch, Tehran 1777613651, Iran
[2] Minist Hlth & Med Educ, Iran Food & Drug Adm IFDA, Food & Drug Reference Control Lab FDRCL, Tehran 1113615911, Iran
[3] Minist Hlth & Med Educ, Iran Food & Drug Adm IFDA, Food & Drug Lab Res Ctr FDLRC, Tehran 1113615911, Iran
[4] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Toxicol & Pharmacol, Tehran 1996835113, Iran
关键词
central composite design; contaminants analysis; gas chromatography-mass spectrometry; grilled meat; PAHs; PCBs; POLYCYCLIC AROMATIC-HYDROCARBONS; PRESSURE GAS-CHROMATOGRAPHY; POLYCHLORINATED-BIPHENYLS; ENVIRONMENTAL CONTAMINANTS; MASS-SPECTROMETRY; EXTRACTION METHOD; PESTICIDES; FOOD; PRODUCTS; EXPOSURE;
D O I
10.3390/foods13010143
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) are recognized as carcinogens and mutagenic food contaminants that threaten public health. As for food safety aspects, control of these contaminants in processed and fatty food is necessary. In this study, eleven factors were screened by the Plackett-Burman design, and four variables were chosen to optimize with the central composite design (CCD) for the improvement of extraction and cleanup procedures of these food contaminants. The optimized variables include 5 g of sample, 2 mL mixture of 2/2/1 ethyl acetate/acetone/isooctane, 1.6 g of ammonium formate, 0.9 g of sodium chloride, and 0.25 g of sorbent Z-Sep+. A 5 min cleanup vortex time with the spike calibration curve strategy, analyzed by gas chromatography-mass spectrometry (GC-MS), led to the validated limits of quantification (LOQs) for 16 PAHs and 36 PCBs of 0.5-2 and 0.5-1 ng/g, respectively, and recoveries of 72-120%, with an average relative standard deviation (%RSD) of 17, for PAHs, and 80-120%, with an %RSD of 3, for PCBs. The method introduces excellent accuracy, precision, and efficiency, and minimizes matrix effects, and ensures a control procedure, adopted with international standards, for food authorities to determine the contaminants of interest in processed meat, and consequently, prevent food-borne disease to improve public health indices.
引用
收藏
页数:20
相关论文
共 50 条
[31]   Determination of multi-pesticide residues in honey with a modified QuEChERS procedure followed by LC-MS/MS and GC-MS/MS [J].
Oymen, Beste ;
Asir, Suleyman ;
Turkmen, Deniz ;
Denizli, Adil .
JOURNAL OF APICULTURAL RESEARCH, 2022, 61 (04) :530-542
[32]   Evaluation of the QuEChERS Method with GC-MS Detection for the Determination of Organochlorine Pesticides in Food of Animal Origin [J].
Surma, Magdalena K. ;
Sadowska-Rociek, Anna B. ;
Cieslik, Ewa J. .
FOOD ANALYTICAL METHODS, 2014, 7 (02) :366-376
[33]   A chemometric optimization of method for determination of nitrosamines in gastric juices by GC-MS [J].
Akyuz, Mehmet ;
Ata, Sevket ;
Dinc, Erdal .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 117 :26-36
[34]   Development of a fast method for the determination of pesticide multiresidues in tomatoes using QuEChERS and GC-MS/MS [J].
Wei, Quanzeng ;
Wu, Mingming ;
Xiao, Fugang ;
Wang, Deguo .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2020, 246 (08) :1563-1572
[35]   Determination of 66 pesticide residues in livestock products using QuEChERS and GC-MS/MS [J].
Kang, Hye Soon ;
Kim, MeeKyung ;
Kim, Eun Jeong ;
Choe, Won-Jo .
FOOD SCIENCE AND BIOTECHNOLOGY, 2020, 29 (11) :1573-1586
[36]   Optimization of a Multi-Residue Analytical Method during Determination of Pesticides in Meat Products by GC-MS/MS [J].
Lee, Sang-Hyeob ;
Kwak, Se-Yeon ;
Sarker, Aniruddha ;
Moon, Joon-Kwan ;
Kim, Jang-Eok .
FOODS, 2022, 11 (19)
[37]   Determination of 2 Phthalic Acid Esters in Fermented Grains by GC-MS/MS Coupled with Modified QuEChERS [J].
Jiang, Lili ;
Shang, Yuhao ;
Li, Fuxiao ;
Tian, Dongwei ;
Zhu, Xiajian ;
Hu, Feng ;
Cheng, Pingyan ;
Hu, Jianfeng .
FOOD ANALYTICAL METHODS, 2024, 17 (04) :574-584
[38]   Simultaneous determination of PAHS, nitro-PAHS and quinones in surface and groundwater samples using SDME/GC-MS [J].
Santos, Leila O. ;
dos Anjos, Jeancarlo P. ;
Ferreira, Sergio L. C. ;
de Andrade, Jailson B. .
MICROCHEMICAL JOURNAL, 2017, 133 :431-440
[39]   Development of a subcritical fluid extraction and GC-MS validation method for polychlorinated biphenyls (PCBs) in marine samples [J].
Jia, Kai ;
Feng, Xiaomei ;
Liu, Kun ;
Han, Yuqian ;
Xue, Yong ;
Xue, Changhu .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 923 :37-42
[40]   Analysis of 19 PCB congeners in catfish tissue using a modified QuEChERS method with GC-MS/MS [J].
Chamkasem, Narong ;
Lee, Sookwang ;
Harmon, Tiffany .
FOOD CHEMISTRY, 2016, 192 :900-906