Flow injection spectrophotometric determination of chromium(VI) after preconcentration on potassium-benzoic acid hydrazide dithiocarbamate

被引:0
作者
Shabir, Rabia [1 ]
Shahida, Shabnam [2 ]
Ghous, Tahseen [3 ]
Khan, Muhammad Imran [4 ]
Ghani, Lubna [5 ]
Yousaf, Saiqa [5 ]
Khan, Ashfaq Ahmed [5 ]
Khan, Mumtaz [6 ]
Bhattarai, Ajaya [7 ]
Shanableh, Abdallah [4 ]
机构
[1] Univ Azad Jammu & Kashmir Muzaffarabad, Dept Chem, Muzaffarabad, Pakistan
[2] Univ Poonch, Dept Chem, Rawalakot, Ajk, Pakistan
[3] Mirpur Univ Sci & Technol MUST, Dept Chem, Mirpur 10250, Ajk, Pakistan
[4] Univ Sharjah, Res Inst Sci & Engn RISE, Sharjah, U Arab Emirates
[5] Women Univ Azad Jammu & Kashmir Bagh, Dept Chem, Bagh, Pakistan
[6] Pakistan Inst Nucl Sci & Technol, Nilore, Pakistan
[7] Tribhuvan Univ, Dept Chem, Mahendra Morang Adarsh Multiple Campus, Biratnagar 56613, Nepal
关键词
Cr(VI); Potassium-benzoic acid hydrazide dithiocarbamate; Column; Preconcentration; Spectrophotometry; 1; 5-diphenylcarbazide; ONLINE PRECONCENTRATION; WASTE-WATER; REMOVAL; ADSORPTION; REDUCTION; CR(III);
D O I
10.5004/dwt.2023.29927
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this study a sensitive, easy to operate, robust and reproducible column preconcentration method was developed for the determination of Cr(VI) by flow injection system coupled with spectropho-tometer. The proposed method is based on the retention of the analyte in a column containing potassium-benzoic acid hydrazide dithiocarbamate from buffered solution of pH 4.0 at a flow rate of 15 mL center dot min-1, and then its elution from the column with 7.0 mol center dot dm-3 nitric acid solution. The eluted Cr(VI) solution was then mixed with 0.25% solution of 1,5-diphenylcarbazide (DPC) and pur-ple-red Cr(VI)-DPC complex was determined spectrophotometrically at 545 nm in acidic medium. The parameters studied include volume, pH, flow rate and concentration of the sample solution, different eluents and their concentration. The proposed method has a linear calibration range from 3-15 mg center dot L-1 of Cr(VI) with the regression y = 0.0467C + 0.0013, R2 = 0.9984. The 3 delta detection limit of Cr(VI) is 1 mu g center dot L-1 with enrichment factor of 4, sampling frequency of 6 samples center dot h-1 and relative standard deviation of 1.82% at 10 mg center dot L-1. The adsorbent used has a good adsorption potential as well as appreciable recovery. The column had a constant performance during all experiments except 2%-3% loss during flow rate optimization. The developed method was effectively employed for the determination of Cr(VI) from standard reference material (CRM Cu1/3 Cu alloy).
引用
收藏
页码:211 / 216
页数:6
相关论文
共 50 条
[41]   FIA-coupled spectrophotometric method for determination of Cr (VI) traces in natural waters: application of in-line dissolution of 1,5-diphenylcarbazide after heat treatment and activated alumina as adsorbent for preconcentration [J].
Meneses, Diogenes ;
Junior, Jose Guimaraes F. ;
Costa de Oliveira, Paulo Cesar .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2018, 190 (10)
[42]   GAS PERMEATION AND PRECONCENTRATION IN THE FLOW-INJECTION DETERMINATION OF ACID-AVAILABLE CYANIDE IN WASTE-WATER [J].
KUBAN, V .
ANALYTICA CHIMICA ACTA, 1992, 259 (01) :45-52
[43]   On-line chromatographic separation and determination of chromium(III) and chromium(VI) with preconcentration of the chromium(III) using potassium hydrogen phthalate, in various samples by flame atomic absorption spectrometry [J].
Gaspar, A ;
Posta, J ;
Toth, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (11) :1067-1074
[44]   Spectrophotometric determination of phenol by flow injection on-line preconcentration with a micro-column containing magnetic microspheres functionalized with Cyanex272 [J].
Ye, Juan-Juan ;
Feng, Wei ;
Tian, Miao-Miao ;
Zhang, Jun-Ling ;
Zhou, Wei-Hong ;
Jia, Qiong .
ANALYTICAL METHODS, 2013, 5 (04) :1046-1051
[45]   Flow injection spectrophotometric determination of acetylsalicylic acid in tablets after on-line microwave-assisted alkaline hydrolysis [J].
Pereira, AV ;
Aniceto, C ;
Fatibello, O .
ANALYST, 1998, 123 (05) :1011-1015
[46]   Spectrophotometric determination of lead in environmental and biological samples by flow injection microcolumn preconcentration and separation using DBMCSA chromogenic agent [J].
Fang, GZ ;
Pan, JM .
CHEMIA ANALITYCZNA, 2005, 50 (05) :925-934
[47]   Determination of europium(III) in environmental samples using a flow injection analysis system with on-line preconcentration and spectrophotometric detection [J].
Shahida, Shabnam ;
Ali, Akbar .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 300 (01) :423-429
[48]   Determination of europium(III) in environmental samples using a flow injection analysis system with on-line preconcentration and spectrophotometric detection [J].
Shabnam Shahida ;
Akbar Ali .
Journal of Radioanalytical and Nuclear Chemistry, 2014, 300 :423-429
[49]   SPECTROPHOTOMETRIC DETERMINATION OF ASCORBIC-ACID IN PHARMACEUTICALS BY BACKGROUND CORRECTION AND FLOW-INJECTION [J].
VERMA, KK ;
JAIN, A ;
VERMA, A ;
CHAURASIA, A .
ANALYST, 1991, 116 (06) :641-645
[50]   Reverse Reference Flow Injection Spectrophotometry for the Determination of Chromium(VI) Extracted from Leather by Artificial Perspiration [J].
Li Wang ;
Zhang Xinshen ;
Li Hui ;
Dai Shijun ;
Sun Dongmei ;
Sun Jing ;
Yang Yujie ;
Tong Ling .
JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2010, 94 (06) :262-267