Flow injection spectrophotometric determination of chromium(VI) after preconcentration on potassium-benzoic acid hydrazide dithiocarbamate

被引:0
作者
Shabir, Rabia [1 ]
Shahida, Shabnam [2 ]
Ghous, Tahseen [3 ]
Khan, Muhammad Imran [4 ]
Ghani, Lubna [5 ]
Yousaf, Saiqa [5 ]
Khan, Ashfaq Ahmed [5 ]
Khan, Mumtaz [6 ]
Bhattarai, Ajaya [7 ]
Shanableh, Abdallah [4 ]
机构
[1] Univ Azad Jammu & Kashmir Muzaffarabad, Dept Chem, Muzaffarabad, Pakistan
[2] Univ Poonch, Dept Chem, Rawalakot, Ajk, Pakistan
[3] Mirpur Univ Sci & Technol MUST, Dept Chem, Mirpur 10250, Ajk, Pakistan
[4] Univ Sharjah, Res Inst Sci & Engn RISE, Sharjah, U Arab Emirates
[5] Women Univ Azad Jammu & Kashmir Bagh, Dept Chem, Bagh, Pakistan
[6] Pakistan Inst Nucl Sci & Technol, Nilore, Pakistan
[7] Tribhuvan Univ, Dept Chem, Mahendra Morang Adarsh Multiple Campus, Biratnagar 56613, Nepal
关键词
Cr(VI); Potassium-benzoic acid hydrazide dithiocarbamate; Column; Preconcentration; Spectrophotometry; 1; 5-diphenylcarbazide; ONLINE PRECONCENTRATION; WASTE-WATER; REMOVAL; ADSORPTION; REDUCTION; CR(III);
D O I
10.5004/dwt.2023.29927
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this study a sensitive, easy to operate, robust and reproducible column preconcentration method was developed for the determination of Cr(VI) by flow injection system coupled with spectropho-tometer. The proposed method is based on the retention of the analyte in a column containing potassium-benzoic acid hydrazide dithiocarbamate from buffered solution of pH 4.0 at a flow rate of 15 mL center dot min-1, and then its elution from the column with 7.0 mol center dot dm-3 nitric acid solution. The eluted Cr(VI) solution was then mixed with 0.25% solution of 1,5-diphenylcarbazide (DPC) and pur-ple-red Cr(VI)-DPC complex was determined spectrophotometrically at 545 nm in acidic medium. The parameters studied include volume, pH, flow rate and concentration of the sample solution, different eluents and their concentration. The proposed method has a linear calibration range from 3-15 mg center dot L-1 of Cr(VI) with the regression y = 0.0467C + 0.0013, R2 = 0.9984. The 3 delta detection limit of Cr(VI) is 1 mu g center dot L-1 with enrichment factor of 4, sampling frequency of 6 samples center dot h-1 and relative standard deviation of 1.82% at 10 mg center dot L-1. The adsorbent used has a good adsorption potential as well as appreciable recovery. The column had a constant performance during all experiments except 2%-3% loss during flow rate optimization. The developed method was effectively employed for the determination of Cr(VI) from standard reference material (CRM Cu1/3 Cu alloy).
引用
收藏
页码:211 / 216
页数:6
相关论文
共 50 条
  • [1] Determination of chromium(III) and chromium(VI) by use of a spectrophotometric sequential injection system
    Mulaudzi, LV
    van Staden, JF
    Stefan, RI
    ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) : 51 - 60
  • [2] FLOW-INJECTION EXTRACTION SPECTROPHOTOMETRIC DETERMINATION OF CHROMIUM(VI) WITH THE BENZYLTRIBUTYLAMMONIUM CATION
    BARAKAT, SA
    BURNS, DT
    HARRIOTT, M
    ANALYTICA CHIMICA ACTA, 1993, 272 (01) : 135 - 138
  • [3] Flow injection online spectrophotometric determination of uranium after preconcentration on XAD-4 resin impregnated with nalidixic acid
    Shahida, Shabnam
    Ali, Akbar
    Khan, Muhammad Haleem
    Saeed, Muhammad Mufazzal
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2013, 185 (02) : 1613 - 1626
  • [4] The simple and rapid spectrophotometric determination of trace chromium(VI) after preconcentration as its colored complex on chitin
    Hoshi, S
    Konuma, K
    Sugawara, K
    Uto, M
    Akatsuka, K
    TALANTA, 1998, 47 (03) : 659 - 663
  • [5] Determination of trace amounts of chromium (VI) by flow injection analysis with chemiluminescence detection
    Kanwal, Shamsa
    Ma, Qiang
    Dou, Wenchao
    Wang, Guannan
    Su, Xingguang
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (02) : 210 - 221
  • [6] Rapid determination of chromium(VI) in electroplating waste water by use of a spectrophotometric flow injection system
    Yuan, Dong
    Fu, Dayou
    Wang, Rong
    Yuan, Jigang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2008, 71 (01) : 276 - 279
  • [7] A GREEN METHOD FOR THE DETERMINATION OF CHROMIUM(VI) AND IRON(III) IN WATER BY SEQUENTIAL INJECTION ANALYSIS AND SPECTROPHOTOMETRIC DETECTION
    Gao, Xia
    Sun, Yuping
    Zhu, Guifen
    Fan, Jing
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2013, 41 (05) : 500 - 511
  • [8] Flow injection online spectrophotometric determination of uranium after preconcentration on XAD-4 resin impregnated with nalidixic acid
    Shabnam Shahida
    Akbar Ali
    Muhammad Haleem Khan
    Muhammad Mufazzal Saeed
    Environmental Monitoring and Assessment, 2013, 185 : 1613 - 1626
  • [9] Determination of Chromium(VI) in waste water by Reversed Flow Injection Spectrophotometry
    Su, Ling
    Xie, Hengshen
    PROGRESS IN ENVIRONMENTAL SCIENCE AND ENGINEERING (ICEESD2011), PTS 1-5, 2012, 356-360 : 939 - 942
  • [10] Flow Injection Spectrophotometric Determination of Chromium(VI) Extracted from Dyed Leather with On-line Decolouring
    Wang Li
    Zhang Xinshen
    Qian Shu
    Zhan Yu
    Chen Shujuan
    JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2012, 96 (04): : 152 - 156