Simultaneous subcutaneous implantable cardioverter-defibrillator and leadless pacemaker implantation for patients at high risk of infection: a retrospective case series report

被引:2
|
作者
Calvagna, Giuseppe M. [1 ]
Valsecchi, Sergio [2 ]
机构
[1] ARNAS Garibaldi Ctr, Dept Cardiol, Catania, Italy
[2] Boston Sci, Milan, Italy
关键词
Implantable defibrillator; Subcutaneous; Leadless pacemaker; Extraction; Infection; ELECTRONIC DEVICE INFECTION; EUROPEAN-SOCIETY; COMPLICATIONS; ASSOCIATION; MORTALITY; ELIGIBILITY; EXTRACTION; MANAGEMENT; THERAPY; HRS;
D O I
10.1007/s10840-023-01684-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe subcutaneous implantable cardioverter defibrillator (S-ICD) and leadless pacemaker (LP) are alternative options for patients at high risk of infection requiring ICD and pacing therapy. In this analysis, we described the simultaneous implantation of S-ICD and LP in patients with high infectious risk.MethodsThe study cohort comprised patients referred to our institution for ICD implantation due to high-risk factors of infection.ResultsBetween 2018 and 2022, 13 patients were referred, including 11 with infected ICD and 2 for first ICD implantation in the presence of high-risk factors. In cases of infected ICD, successful extraction was performed using a mechanical dilatation technique. Reimplantation was delayed until resolution of infection with antibiotic therapy. The devices were implanted during a single procedure, with S-ICD implantation following LP placement for verification of sensing adequacy through surface ECG screening. Suitable vectors for sensing during inhibited and ventricular pacing were identified in all patients. Defibrillation testing was effective, and no issues with double counting or undersensing were observed. The postoperative period was uneventful, and during a median follow-up of 35 months, no complications or infections were reported. The median ventricular pacing percentage was 5%, and a single inappropriate shock episode due to myopotential interference was reported and resolved by reprogramming the sensing vector.ConclusionSimultaneous implantation of S-ICD and LP is feasible and safe in patients at high risk of infection requiring both ICD and pacing therapy. This combined approach provides an effective solution for these patients.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Survival Following Implantable Cardioverter-Defibrillator Implantation in Patients With Amyloid Cardiomyopathy
    Higgins, Angela Y.
    Annapureddy, Amarnath R.
    Wang, Yongfei
    Minges, Karl E.
    Lampert, Rachel
    Rosenfeld, Lynda E.
    Jacoby, Daniel L.
    Curtis, Jeptha P.
    Miller, Edward J.
    Freeman, James V.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2020, 9 (18):
  • [32] Long-term performance of a novel communicating antitachycardia pacing-enabled leadless pacemaker and subcutaneous implantable cardioverter-defibrillator system: A comprehensive preclinical study
    Breeman, Karel T. N.
    Swackhamer, Bryan
    Brisben, Amy J.
    Quast, Anne -Floor B. E.
    Carter, Nathan
    Shuros, Allan
    Soltis, Brian
    Koop, Brendan E.
    Burke, Martin C.
    Wilde, Arthur A. M.
    Tjong, Fleur V. Y.
    Knops, Reinoud E.
    HEART RHYTHM, 2022, 19 (05) : 837 - 846
  • [33] Optimizing patient selection for primary prevention implantable cardioverter-defibrillator implantation: utilizing multimodal machine learning to assess risk of implantable cardioverter-defibrillator non-benefit
    Kolk, Maarten Z. H.
    Ruiperez-Campillo, Samuel
    Deb, Brototo
    Bekkers, Erik J.
    Allaart, Cornelis P.
    Rogers, Albert J.
    van der Lingen, Anne-Lotte C. J.
    Florez, Laura Alvarez
    Isgum, Ivana
    De Vos, Bob D.
    Clopton, Paul
    Wilde, Arthur A. M.
    Knops, Reinoud E.
    Narayan, Sanjiv M.
    Tjong, Fleur V. Y.
    EUROPACE, 2023, 25 (09):
  • [34] Effect of malnutrition on outcomes of patients hospitalized for implantable cardioverter-defibrillator implantation
    Asemota, Iriagbonse Rotimi
    Shaka, Hafeez
    Akuna, Emmanuel
    Edigin, Ehizogie
    Adeoti, Oluwatomi
    HEART RHYTHM, 2022, 19 (05) : 858 - 859
  • [35] Safety of pacemaker and implantable cardioverter-defibrillator implantation during uninterrupted warfarin treatment - The FinPAC study
    Airaksinen, K. E. Juhani
    Korkeila, Petri
    Lund, Juha
    Ylitalo, Antti
    Karjalainen, Pasi
    Virtanen, Vesa
    Raatikainen, Pekka
    Koivisto, Ulla-Maija
    Koistinen, Juhani
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) : 3679 - 3682
  • [36] Transcutaneous lead implantation connected to an externalized pacemaker in patients with implantable cardiac defibrillator/pacemaker infection and pacemaker dependency
    Pecha, Simon
    Aydin, Muhammed Ali
    Yildirim, Yalin
    Sill, Bjoern
    Reiter, Beate
    Wilke, Iris
    Reichenspurner, Hermann
    Treede, Hendrik
    EUROPACE, 2013, 15 (08): : 1205 - 1209
  • [37] Quality of life in patients with a subcutaneous vs. transvenous implantable cardioverter-defibrillator
    Jagosz, Marta
    Jedrzejczyk-Patej, Ewa
    Kowalska, Wiktoria
    Mazurek, Michal
    Warwas, Szymon
    Wiktor, Dominika
    Sokal, Adam
    Kowalski, Oskar
    Lenarczyk, Radostaw
    Sredniawa, Beata
    Kalarus, Zbigniew
    KARDIOLOGIA POLSKA, 2022, 80 (06) : 679 - 684
  • [38] Eligibility for subcutaneous implantable cardioverter-defibrillator in patients with left ventricular assist device
    Zormpas, Christos
    Eiringhaus, Joerg
    Hillmann, Henrike A. K.
    Hohmann, Stephan
    Mueller-Leisse, Johanna
    Schmitto, Jan D.
    Veltmann, Christian
    Duncker, David
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 60 (02) : 303 - 311
  • [39] Design and rationale of the MODULAR ATP global clinical trial: A novel intercommunicative leadless pacing system and the subcutaneous implantable cardioverter-defibrillator
    Lloyd, Michael S.
    Brisben, Amy J.
    Reddy, Vivek Y.
    Blomstrom-Lundqvist, Carina
    Boersma, Lucas V. A.
    Bongiorni, Maria Grazia
    Burke, Martin C.
    Cantillon, Daniel J.
    Doshi, Rahul
    Friedman, Paul A.
    Gras, Daniel
    Kutalek, Steven P.
    Neuzil, Petr
    Roberts, Paul R.
    Wright, David J.
    Appl, Ursula
    West, Julie
    Carter, Nathan
    Stein, Kenneth M.
    Mont, Lluis
    Knops, Reinoud E.
    HEART RHYTHM O2, 2023, 4 (07): : 448 - 456
  • [40] Use of pulsed electron avalanche knife (PEAK) PlasmaBlade™ in patients undergoing implantation of subcutaneous implantable cardioverter-defibrillator
    Kaya, Elif
    Siebermair, Johannes
    Azizy, Obayda
    Dobrev, Dobromir
    Rassaf, Tienush
    Wakili, Reza
    IJC HEART & VASCULATURE, 2019, 24