The development of a clearance level radioactive waste measurement system using an array of NaI(Tl) detectors

被引:1
作者
Li, C. G. [1 ]
Gao, F. [1 ]
Sun, H. M. [1 ]
Zhao, D. S. [1 ]
Su, M. [1 ]
Bai, H. Y. [1 ]
Xiong, Z. H. [1 ]
Mo, Z. H. [1 ]
机构
[1] China Acad Engn Phys, Inst Mat, Mianyang 621908, Peoples R China
基金
中国国家自然科学基金;
关键词
Clearance level radioactive waste; NaI(Tl) detector array; Detection efficiency; Minimum detectable activity; EFFICIENCY;
D O I
10.1016/j.nima.2023.168748
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In order to meet the needs of rapid classification and measurement of the radioactive waste, a clearance level radioactive waste measurement system has been successfully developed and applied, achieving the goal of waste minimization. The measurement system consisted of 34 NaI(Tl) detectors taking into account the detector layout, detection efficiency and shielding chamber (to reduce the background of the environment). The NaI(Tl) detector array was built by a geometric condition of spatially symmetric to measure gamma rays. The shielding chamber composed of 2 mm copper and 10 mm lead is used as an passive shielding, and the radioactive waste is placed inside the shielding chamber, which suppress the gamma rays from the decay of 40K, 208Tl and other nuclides in the environment. A method to determine the counting of energy interval for the gamma rays is proposed to obtain the radioactivity of the radioactive waste package. The performance testing results of the measurement system show that the energy resolution and efficiency for 661.7 keV (137Cs) are 7.84% and 69.49% respectively, and the minimum detectable activity of 137Cs is 24.52 Bq. All these indicate that the indices of the clearance level radioactive waste measurement system have reached the international recommended level.
引用
收藏
页数:5
相关论文
共 22 条
  • [1] Efficiency of a cubic NaI(Tl) detector with rectangular cavity using standard radioactive point sources placed at non-axial position
    Abbas, Mahmoud, I
    Badawi, Mohamed S.
    Thabet, Abouzeid A.
    Kopatch, Yu N.
    Ruskov, Ivan N.
    Grozdanov, D. N.
    Noureddine, Salam
    Fedorov, N. A.
    Gouda, Mona M.
    Hramco, C.
    Abd-Elzaher, Mohamed
    Hamzawy, A.
    Elsafi, Mohamed
    El-Khatib, Ahmed M.
    [J]. APPLIED RADIATION AND ISOTOPES, 2020, 163
  • [2] Calibration of a single hexagonal NaI(Tl) detector using a new numerical method based on the efficiency transfer method
    Abbas, Mahmoud I.
    Badawi, M. S.
    Ruskov, I. N.
    El-Khatib, A. M.
    Grozdanov, D. N.
    Thabet, A. A.
    Kopatch, Yu. N.
    Gouda, M. M.
    Skoy, V. R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 771 : 110 - 114
  • [3] Evaluation of performance of gamma tomographic technique for correcting lump effect in radioactive waste assay
    Anh, TH
    Dung, TQ
    [J]. ANNALS OF NUCLEAR ENERGY, 2001, 28 (03) : 265 - 273
  • [4] [Anonymous], WM2900 Series Segmented Assay System
  • [5] [Anonymous], WM2200 Series Segmented Assay System
  • [6] [Anonymous], IQ3 Automated Low Level Waste System
  • [7] [Anonymous], WM2110 Series Q2 Low Level Waste Assay Systems
  • [8] [Anonymous], 1995, National Standard of the People's Republic of China. GB9133-1995
  • [9] [Anonymous], AVATAR-F High-Speed Scintillator Digital Multi-Channel
  • [10] Characterization of the efficiency of a cubic NaI detector with rectangular cavity for axially positioned sources
    Badawi, M. S.
    Noureddine, S.
    Kopatch, Y. N.
    Abbas, M., I
    Ruskov, I. N.
    Grozdanov, D. N.
    Thabet, A. A.
    Fedorov, N. A.
    Gouda, M. M.
    Hramco, C.
    Abd-Elzaher, M.
    Hamzawy, A.
    Elsafi, M.
    El-Khatib, A. M.
    [J]. JOURNAL OF INSTRUMENTATION, 2020, 15 (02)