Effect of cumulative radiation exposure from Coronary catheterization on lung cancer mortality

被引:1
作者
Liu, Jin [1 ,2 ]
Chen, Shiqun [1 ,2 ,3 ]
Zhou, Yang [1 ,2 ]
Zheng, Xueyan [4 ]
Meng, Ruilin [4 ]
Tan, Ning [1 ,2 ,5 ,6 ]
Liu, Yong [1 ,2 ,5 ,6 ]
机构
[1] Guangdong Acad Med Sci, Guangdong Prov Peoples Hosp, Guangdong Cardiovasc Inst, Dept Cardiol, Guangzhou, Peoples R China
[2] Guangdong Acad Med Sci, Guangdong Prov Peoples Hosp, Guangdong Cardiovasc Inst, Dept Guangdong Prov Key Lab Coronary Heart Dis Pre, Guangzhou, Peoples R China
[3] Guangdong Acad Med Sci, Guangdong Prov Peoples Hosp, Global Hlth Res Ctr, Guangzhou, Peoples R China
[4] Guangdong Prov Ctr Dis Control & Prevent, Inst Control & Prevent Chron Non Infect Dis, Guangzhou, Peoples R China
[5] Southern Med Univ, Sch Clin Med 2, Guangzhou, Peoples R China
[6] South China Univ Technol, Guangdong Prov Peoples Hosp, Sch Med, Guangzhou, Peoples R China
关键词
Lung cancer mortality; Coronary catheterization; Radiation; DOSE IONIZING-RADIATION; CARDIOVASCULAR-DISEASE; RISK; ANGIOGRAPHY;
D O I
10.1186/s12885-023-11231-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Coronary catheterization (CC) procedure inevitably exposes patients with cardiovascular disease (CVD) to radiation, while cumulative radiation exposure may lead to higher risk of cancer. Methods This multi-center, retrospective study was based on the CC procedure in Cardiorenal ImprovemeNt II cohort (CIN-II, NCT05050877) among five regional central tertiary teaching hospitals in China between 2007 and 2020. Patients without known cancer were stratified according to the times they received CC procedure. Baseline information from their last CC procedure was analyzed. Cox regression and Fine-Gray competing risk models were used to assess the relationship between cumulative radiation exposure from CC procedures and cancer-specific, all-cause and cardiovascular mortality. Results Of 136,495 hospitalized survivors without cancer at baseline (mean age: 62.3 +/- 11.1 years, 30.9% female), 116,992 patients (85.7%) underwent CC procedure once, 15,184 patients (11.1%) on twice, and 4,319 patients (3.2%) underwent CC procedure more than three times. During the median follow-up of 4.7 years (IQR: 2.5 to 7.4), totally 18,656 patients (13.7%) died after discharge, of which 617 (0.5%) died of lung cancer. Compared with the patients who underwent CC procedure once, the risk of lung cancer mortality increased significantly with the increase of the number of CC procedure (CC 2 times vs. 1 time: HR 1.42, 95% CI 1.13 to 1.78, P < 0.001; CC >= 3 times vs. 1 time: HR 1.64, 95%CI 1.13 to 2.39, P < 0.05). Similar results were observed in all-cause mortality and cardiovascular mortality, but not in other cancer-specific mortality. Conclusions Our data suggest that substantial proportion of CVD patients are exposed to multiple high levels of low-dose ionizing radiation from CC procedure, which is associated with an increased risk of cancer mortality in this population.
引用
收藏
页数:9
相关论文
共 30 条
[1]   Novel Breast Cancer Risk Alleles and Interaction with Ionizing Radiation among US Radiologic Technologists [J].
Bhatti, Parveen ;
Doody, Michele M. ;
Rajaraman, Preetha ;
Alexander, Bruce H. ;
Yeager, Meredith ;
Hutchinson, Amy ;
Burdette, Laurie ;
Thomas, Gilles ;
Hunter, David J. ;
Simon, Steven L. ;
Weinstock, Robert M. ;
Rosenstein, Marvin ;
Stovall, Marilyn ;
Preston, Dale L. ;
Linet, Martha S. ;
Hoover, Robert N. ;
Chanock, Stephen J. ;
Sigurdson, Alice J. .
RADIATION RESEARCH, 2010, 173 (02) :214-224
[2]   Cancer Therapy-Related Cardiovascular Complications in Clinical Practice: Current Perspectives [J].
Bohdan, Michal ;
Kowalczys, Anna ;
Mickiewicz, Agnieszka ;
Gruchala, Marcin ;
Lewicka, Ewa .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (08)
[3]   Patient doses and dosimetric evaluations in interventional cardiology [J].
Bor, Dogan ;
Olgar, Turan ;
Toklu, Tuerkay ;
Caglan, Ayca ;
Oenal, Elif ;
Padovani, Renato .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (01) :31-42
[4]   Estimated radiation risks potentially associated with full-body CT screening [J].
Brenner, DJ ;
Elliston, CD .
RADIOLOGY, 2004, 232 (03) :735-738
[5]   Cumulative Exposure to Ionizing Radiation From Diagnostic and Therapeutic Cardiac Imaging Procedures [J].
Chen, Jersey ;
Einstein, Andrew J. ;
Fazel, Reza ;
Krumholz, Harlan M. ;
Wang, Yongfei ;
Ross, Joseph S. ;
Ting, Henry H. ;
Shah, Nilay D. ;
Nasir, Khurram ;
Nallamothu, Brahmajee K. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (09) :702-711
[6]   Sex Differences in Characteristics, Treatments, and In-hospital Outcomes of Patients Undergoing Coronary Angiography or Intervention [J].
Chen, Shi-Qun ;
Liu, Jin ;
Zhou, Yang ;
Huang, Zhi-Dong ;
Xie, Yun ;
Huang, Hao-Zhang ;
Yan, Xiao-Ming ;
Xie, Yong-Yi ;
Hao, Peng-Fei ;
Liang, Yan ;
Dong, Shao-Hong ;
Huang, Xiao-Yu ;
Chen, Li-Ling ;
Tan, Ning ;
Liu, Yong ;
Chen, Ji-Yan .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
[7]   Exposure to Low-Dose Ionizing Radiation From Cardiac Procedures and Malignancy Risk in Adults With Congenital Heart Disease [J].
Cohen, Sarah ;
Liu, Aihua ;
Gurvitz, Michelle ;
Guo, Liming ;
Therrien, Judith ;
Laprise, Claudie ;
Kaufman, Jay S. ;
Abrahamowicz, Michal ;
Marelli, Ariane J. .
CIRCULATION, 2018, 137 (13) :1334-+
[8]   Radiation-Related Cancer Risks From CT Colonography Screening: A Risk-Benefit Analysis [J].
de Gonzalez, Amy Berrington ;
Kim, Kwang Pyo ;
Knudsen, Amy B. ;
Lansdorp-Vogelaar, Iris ;
Rutter, Carolyn M. ;
Smith-Bindman, Rebecca ;
Yee, Judy ;
Kuntz, Karen M. ;
van Ballegooijen, Marjolein ;
Zauber, Ann G. ;
Berg, Christine D. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (04) :816-823
[9]   Analysis of Computed Tomography Radiation Doses Used for Lung Cancer Screening Scans [J].
Demb, Joshua ;
Chu, Philip ;
Yu, Sophronia ;
Whitebird, Robin ;
Solberg, Leif ;
Miglioretti, Diana L. ;
Smith-Bindman, Rebecca .
JAMA INTERNAL MEDICINE, 2019, 179 (12) :1650-1657
[10]   Cancer risk related to low-dose ionizing radiation from cardiac imaging in patients after acute myocardial infarction [J].
Eisenberg, Mark J. ;
Afilalo, Jonathan ;
Lawler, Patrick R. ;
Abrahamowicz, Michal ;
Richard, Hugues ;
Pilote, Louise .
CANADIAN MEDICAL ASSOCIATION JOURNAL, 2011, 183 (04) :430-436