摘要
The fault-tolerant control after phase loss is crucial in the studies of the six-phase permanent magnet synchronous motor (PMSM), and the one phase loss is the most frequent phase loss fault. To improve the system instability caused by nonlinear and time-varying perturbations of inductance parameters in a double-Y phase shifted 30 & DEG; six-phase PMSM, an improved deadbeat predictive current fault-tolerant control (DPC-FTC) method is proposed in this study. The transformation matrix after single-phase open-phase is first reduced and reconstructed, and the reduced-dimensional voltage equation is derived. Based on this equation, the deadbeat current predictive control is then used to predict the expected voltage using the current feedback value and the reference value, so as to shorten the response time and improve the overall control effect. The voltage equation after parameter perturbation is rewritten, and the current discrete transfer function under constant expected voltage before and after parameter perturbation is calculated. Afterwards, to further improve the low stability of fault-tolerant control after phase loss, which is caused by the inductance parameter perturbation of the control system, the weight coefficient is introduced in order to enhance the deadbeat predictive current control so that it splits and optimizes the direct-quadrature axis current. The stability of the system is then analyzed. By changing the weight coefficient, the fault-tolerant control system has a wider stable working range. Finally, the simulation model and experimental platform are completed. The results show that the improved DPC-FTC method improves the permissible inductor parameter uptake range by a factor of 1/& beta;, reduces the current static difference by 32.05% and 46.02% when the inductor parameter is mismatched by a factor of 2, reduces the current oscillation and effectively reduces the sensitivity of system stability to inductor parameter uptake.
引用
收藏
页数:29
相关论文
共 50 条
  • [31] Phase-Shifting Fault-Tolerant Control of Permanent-Magnet Linear Motors With Single-Phase Current Sensor
    Wang, Wei
    Zeng, Xinlu
    Hua, Wei
    Wang, Zheng
    Cheng, Ming
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (03) : 2414 - 2425
  • [32] Fault Tolerant Vector Controlled Five-Phase Permanent Magnet Synchronous Motor Drive With an Open Phase
    Hosseyni, Anissa
    Trabelsi, Ramzi
    Mimouni, Med Faouzi
    Iqbal, Atif
    2018 15TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS AND DEVICES (SSD), 2018, : 780 - 784
  • [33] Reliability Analysis approach to Fault Tolerant Permanent Magnet Synchronous Motor System
    Xu Jinquan
    Guo Hong
    Kuang Xiaolin
    Zhou Tong
    2016 IEEE VEHICLE POWER AND PROPULSION CONFERENCE (VPPC), 2016,
  • [34] Simplified Fault-Tolerant Model Predictive Control for a Five-Phase Permanent-Magnet Motor With Reduced Computation Burden
    Tao, Tao
    Zhao, Wenxiang
    Du, Yuxuan
    Cheng, Yu
    Zhu, Jihong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (04) : 3850 - 3858
  • [35] Direct Control of Bearingless Permanent Magnet Synchronous Motor Based on Prediction Model
    Zhu, Huangqiu
    Wu, Mingcan
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2021, 101 : 127 - 138
  • [36] Open phase fault-tolerant support vector machine predictive power control for six-phase induction generator WECS
    Hamoudi, Yanis
    Abdolrasol, Maher G. M.
    Amimeur, Hocine
    Hassaini, Faycal
    Ker, Pin Jern
    Ustun, Taha Selim
    ENERGY EXPLORATION & EXPLOITATION, 2025, 43 (02) : 744 - 775
  • [37] Current control designed with model based predictive control for six-phase motor drives
    Ayala, Magno
    Doval-Gandoy, Jesus
    Rodas, Jorge
    Gonzalez, Osvaldo
    Gregor, Raul
    ISA TRANSACTIONS, 2020, 98 (98) : 496 - 504
  • [38] Deadbeat Predictive Current Control of Permanent-Magnet Synchronous Motors with Stator Current and Disturbance Observer
    Zhang, Xiaoguang
    Hou, Benshuai
    Mei, Yang
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (05) : 3818 - 3834
  • [39] Fault-Tolerant Control of Five-Phase Permanent-Magnet Motors With Trapezoidal Back EMF
    Dwari, Suman
    Parsa, Leila
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (02) : 476 - 485
  • [40] Study on the Design of Six-Phase Surface Inset Permanent Magnet Synchronous Generator and Motor Considering the Power Factor and Torque Ripple
    Kim, Hyunwoo
    Park, Yeji
    Oh, Seung-Taek
    Jin, Chang-Sung
    Lee, Ju
    Kim, Won-Ho
    IEEE TRANSACTIONS ON MAGNETICS, 2022, 58 (02)