Surface Plasmon Resonance Microscopy Based on Total Internal Reflection

被引:5
|
作者
Zhang, Teliang [1 ]
Wang, Xueliang [1 ]
Zeng, Youjun [2 ]
Huang, Songfeng [1 ]
Dai, Xiaoqi [1 ]
Kong, Weifu [1 ]
Liu, Qian [1 ]
Chen, Jiajie [1 ]
Qu, Junle [1 ]
Shao, Yonghong [1 ]
机构
[1] Shenzhen Univ, Coll Phys & Optoelect Engn, Key Lab Optoelect Devices & Syst, Minist Educ & Guangdong Prov, Shenzhen 518060, Peoples R China
[2] Guangdong Univ Technol, Coll Phys & Optoelect Engn, Guangzhou 510006, Peoples R China
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 02期
基金
中国国家自然科学基金;
关键词
total internal reflection; surface plasmon resonance; surface plasmon resonance microscopy; biomolecular interaction;
D O I
10.3390/bios13020261
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Surface plasmon resonance microscopy (SPRM) has been widely employed in biological fields because of its high spatial resolution and label-free detection modality. In this study, SPRM based on total internal reflection (TIR) is studied via a home-built SPRM system, and the principle of imaging of a single nanoparticle is analyzed as well. By designing a ring filter and combining it with the deconvolution algorithm in Fourier space, the parabolic tail of the nanoparticle image is removed, in which a spatial resolution of 248 nm is obtained. In addition, we also measured the specific binding between the human IgG antigen and goat anti-human IgG antibody using the TIR-based SPRM. The experimental results have proved that the system can image sparse nanoparticles and monitor biomolecular interactions.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Surface plasmon resonance biosensing by electro-optically modulated attenuated total reflection
    T.-J. Wang
    C.-C. Cheng
    S.-C. Yang
    Applied Physics B, 2011, 103 : 701 - 706
  • [42] Attenuated-total-reflection predictions to surface-plasmon resonance in a layered structure
    Singh, DB
    Tripathi, VK
    JOURNAL OF APPLIED PHYSICS, 2005, 98 (05)
  • [43] Triangular resonator based on surface plasmon resonance of attenuated reflection mirror
    Kim, D. G.
    Choi, W. K.
    Choi, Y. W.
    Dagli, N.
    ELECTRONICS LETTERS, 2007, 43 (24) : 1365 - 1367
  • [44] A surface plasmon resonance sensor probe based on retro-reflection
    Cahill, CP
    Johnston, KS
    Yee, SS
    SENSORS AND ACTUATORS B-CHEMICAL, 1997, 45 (02) : 161 - 166
  • [45] Partial internal reflections on total internal reflection fluorescent microscopy
    Simon, Sanford M.
    TRENDS IN CELL BIOLOGY, 2009, 19 (11) : 661 - 668
  • [46] Surface Plasmonic Resonance: The Underlying Fano Resonance Mechanism for the Attenuated Total Internal Reflection (ATIR)
    Parrish, Trevor
    Yang, Weiguo
    IEEE SOUTHEASTCON 2020, 2020,
  • [47] Spatial resolution in prism-based surface plasmon resonance microscopy
    Laplatine, Loic
    Leroy, Loic
    Calemczuk, Roberto
    Baganizi, Dieudonne
    Marche, Patrice N.
    Roupioz, Yoann
    Livache, Thierry
    OPTICS EXPRESS, 2014, 22 (19): : 22771 - 22785
  • [48] Effect of Defocus on Surface Plasmon Resonance Microscopy
    Huo Tong
    Wang Liang'an
    Wang Xue
    Sun Xiaojuan
    Sun Xuqing
    Liu Hongyao
    Huang Shangyong
    Yu Hui
    Lu Xinchao
    Huang Chengjun
    ACTA OPTICA SINICA, 2022, 42 (23)
  • [49] Recent Advances in Surface Plasmon Resonance Microscopy
    Huang, Songfeng
    Chen, Jiajie
    Zhang, Teliang
    Dai, Xiaoqi
    Wang, Xueliang
    Zhou, Jianxing
    Kong, Weifu
    Liu, Qian
    Qu, Junle
    Shao, Yonghong
    CHEMOSENSORS, 2022, 10 (12)
  • [50] Flexible hyperspectral surface plasmon resonance microscopy
    Liu, Ziwei
    Wu, Jingning
    Cai, Chen
    Yang, Bo
    Qi, Zhi-mei
    NATURE COMMUNICATIONS, 2022, 13 (01)