Improved pH measurement of mobile phases in reversed-phase liquid chromatography

被引:3
|
作者
Heering, Agnes [1 ]
Lahe, Markus [1 ]
Vilbaste, Martin [1 ]
Saame, Jaan [1 ]
Samin, John Paulo [1 ]
Leito, Ivo [1 ]
机构
[1] Univ Tartu UT, Inst Chem, Ravila St 14a, EE-50411 Tartu, Estonia
关键词
MASS SPECTROMETRY; PK(A) VALUES; UNIFIED PH; GIBBS ENERGIES; SALT BRIDGE; SINGLE IONS; WATER; ACIDS; RETENTION; MIXTURES;
D O I
10.1039/d3an02029k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mobile phase pH is a critically important parameter in reversed-phase liquid chromatographic (RPLC) separations involving analytes that display acidic or basic properties in the pH range used for the mobile phase. The main problem in measuring mobile phase pH lies in the fact that RPLC mobile phases are typically aqueous-organic mixtures. In addition to experimental difficulties, the pH values refer to different aqueous-organic compositions that cannot be correctly compared. Given this situation, the unified pH (wabspH, also termed as ) based on the absolute chemical potential of the solvated proton has been proposed as a rigorous way of characterising mobile phase acidity that is fully inter-comparable between mobile phases of any composition. Here we report the wabspH values of 78 reversed-phase liquid chromatography-mass spectrometry mobile phases that were carefully measured by potential differences in a symmetric cell with two glass electrode half-cells and almost ideal ionic liquid triethylamylammonium bis((trifluoromethyl)sulfonyl)imide [N2225][NTf2] salt bridge with multiple overlapping measurements. The system of altogether 300 Delta wabspH values was anchored to the pH value of standard pH 7.00 aqueous buffer solution. The consistency standard deviation of the whole set of measurements was 0.09 pH units. In addition to the differential potentiometric reference method, simpler measurement methods that use double junction reference or double junction combined electrodes were tested and were found suitable for routine laboratories if high accuracy is not required. Mobile phase unified pH was investigated using several methods to provide pH values comparable between different mobile phase compositions. A double junction combined electrode filled with ionic liquid was tested for the first time.
引用
收藏
页码:1481 / 1488
页数:8
相关论文
共 50 条
  • [41] Wide injection zone compression in gradient reversed-phase liquid chromatography
    Gilar, Martin
    McDonald, Thomas S.
    Johnson, Jay S.
    Murphy, James P.
    Jorgenson, James W.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1390 : 86 - 94
  • [42] Heavy water enhancement of fluorescence signal in reversed-phase liquid chromatography
    Taborsky, Petr
    Kucera, Josef
    Jurica, Jan
    Pes, Ondrej
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1092 : 7 - 14
  • [43] Modern Trends and Best Practices in Mobile-Phase Selection in Reversed-Phase Chromatography
    Dong, Michael W.
    Boyes, Barry E.
    LC GC NORTH AMERICA, 2018, 36 (10) : 752 - 768
  • [44] Modern Trends and Best Practices in Mobile-Phase Selection in Reversed-Phase Chromatography
    Dong, Michael W.
    Boyes, Barry E.
    LC GC EUROPE, 2018, 31 (10) : 572 - +
  • [45] Chemometric-assisted method development in reversed-phase liquid chromatography
    Cela, R.
    Ordonez, E. Y.
    Quintana, J. B.
    Rodil, R.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1287 : 2 - 22
  • [46] Suppression of peak tailing of phosphate prodrugs in reversed-phase liquid chromatography
    Zhang, Jin
    Wang, Qinggang
    Kleintop, Brent
    Raglione, Thomas
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 98 : 247 - 252
  • [47] Comparison of reversed-phase and hydrophilic interaction liquid chromatography for the separation of ephedrines
    Heaton, James
    Gray, Nicola
    Cowan, David A.
    Plumb, Robert S.
    Legido-Quigley, Cristina
    Smith, Norman W.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1228 : 329 - 337
  • [48] Assessment of antibody fragmentation by reversed-phase liquid chromatography and mass spectrometry
    Liu, Hongcheng
    Gaza-Bulseco, Georgeen
    Lundell, Edwin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 876 (01): : 13 - 23
  • [49] Recovery of Proteins Affected by Mobile Phase Trifluoroacetic Acid Concentration in Reversed-Phase Chromatography
    Bobaly, Balazs
    Mikola, Vivien
    Sipko, Eniko
    Marta, Zoltan
    Fekete, Jeno
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (07) : 1078 - 1083
  • [50] Online combination of reversed-phase/reversed-phase and porous graphitic carbon liquid chromatography for multicomponent separation of proteomics and glycoproteomics samples
    Lam, Maggie P. Y.
    Lau, Edward
    Siu, S. O.
    Ng, Dominic C. M.
    Kong, Ricky P. W.
    Chiu, Philip C. N.
    Yeung, William S. B.
    Lo, Clive
    Chu, Ivan K.
    ELECTROPHORESIS, 2011, 32 (21) : 2930 - 2940