Improved pH measurement of mobile phases in reversed-phase liquid chromatography

被引:3
|
作者
Heering, Agnes [1 ]
Lahe, Markus [1 ]
Vilbaste, Martin [1 ]
Saame, Jaan [1 ]
Samin, John Paulo [1 ]
Leito, Ivo [1 ]
机构
[1] Univ Tartu UT, Inst Chem, Ravila St 14a, EE-50411 Tartu, Estonia
关键词
MASS SPECTROMETRY; PK(A) VALUES; UNIFIED PH; GIBBS ENERGIES; SALT BRIDGE; SINGLE IONS; WATER; ACIDS; RETENTION; MIXTURES;
D O I
10.1039/d3an02029k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mobile phase pH is a critically important parameter in reversed-phase liquid chromatographic (RPLC) separations involving analytes that display acidic or basic properties in the pH range used for the mobile phase. The main problem in measuring mobile phase pH lies in the fact that RPLC mobile phases are typically aqueous-organic mixtures. In addition to experimental difficulties, the pH values refer to different aqueous-organic compositions that cannot be correctly compared. Given this situation, the unified pH (wabspH, also termed as ) based on the absolute chemical potential of the solvated proton has been proposed as a rigorous way of characterising mobile phase acidity that is fully inter-comparable between mobile phases of any composition. Here we report the wabspH values of 78 reversed-phase liquid chromatography-mass spectrometry mobile phases that were carefully measured by potential differences in a symmetric cell with two glass electrode half-cells and almost ideal ionic liquid triethylamylammonium bis((trifluoromethyl)sulfonyl)imide [N2225][NTf2] salt bridge with multiple overlapping measurements. The system of altogether 300 Delta wabspH values was anchored to the pH value of standard pH 7.00 aqueous buffer solution. The consistency standard deviation of the whole set of measurements was 0.09 pH units. In addition to the differential potentiometric reference method, simpler measurement methods that use double junction reference or double junction combined electrodes were tested and were found suitable for routine laboratories if high accuracy is not required. Mobile phase unified pH was investigated using several methods to provide pH values comparable between different mobile phase compositions. A double junction combined electrode filled with ionic liquid was tested for the first time.
引用
收藏
页码:1481 / 1488
页数:8
相关论文
共 50 条
  • [21] Thermodynamic Insights into the Separation of Carotenoids in Reversed-Phase Liquid Chromatography
    Marchetti, Nicola
    Giovannini, Pier Paolo
    Catani, Martina
    Pasti, Luisa
    Cavazzini, Alberto
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 2019
  • [22] Analysis of vanilla extract by reversed phase liquid chromatography using water rich mobile phases
    Lavine, Barry K.
    Corona, Desire T.
    MICROCHEMICAL JOURNAL, 2012, 103 : 49 - 61
  • [23] Preparation and Chromatographic Evaluation of Columns for Reversed-Phase Liquid Chromatography
    Zhang, Mengyao
    Wang, Haibo
    Chen, Hui
    Sun, Xiaoli
    Jiang, Ru
    ACTA CHIMICA SLOVENICA, 2011, 58 (01) : 60 - 68
  • [24] Thermodynamic interpretation of the drift and noise of gradient baselines in reversed-phase liquid chromatography using mobile phase additives
    Gritti, Fabrice
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1633 (1633)
  • [25] Estimating the hydrophobicity extent of molecular fragments using reversed-phase liquid chromatography
    Carotti, Andrea
    Varfaj, Ina
    Pruscini, Ilaria
    Abualzulof, Ghaid W. A.
    Mercolini, Laura
    Bianconi, Elisa
    Macchiarulo, Antonio
    Camaioni, Emidio
    Sardella, Roccaldo
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (18)
  • [26] In silico method development for the reversed-phase liquid chromatography separation of proteins using chaotropic mobile phase modifiers
    Ahmad, Imad A. Haidar
    Bennett, Raffeal
    Makey, Devin
    Shchurik, Vladimir
    Lhotka, Hayley
    Mann, Benjamin F.
    McClain, Ray
    Lu, Tian
    Hua, Xiaoqing
    Strulson, Christopher A.
    Loughney, John W.
    Mangion, Ian
    Makarov, Alexey A.
    Regalado, Erik L.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1173
  • [27] Void volume markers in reversed-phase and biomimetic liquid chromatography
    Tsopelas, Fotios
    Ochsenkuehn-Petropoulou, Maria
    Tsantili-Kakoulidou, Anna
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (17) : 2847 - 2854
  • [28] Cholesterol capillary monolithic columns for reversed-phase liquid chromatography
    Grzywinski, Damian
    Szumski, Michal
    Buszewski, Boguslaw
    PROCEEDINGS OF THE 11TH INTERNATIONAL STUDENTS CONFERENCE "MODERN ANALYTICAL CHEMISTRY", 2015, : 12 - 18
  • [29] Performance of different C18 columns in reversed-phase liquid chromatography with hydro-organic and micellar-organic mobile phases
    Ruiz-Angel, M. J.
    Pous-Torres, S.
    Carda-Broch, S.
    Garcia-Alvarez-Coque, M. C.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1344 : 76 - 82
  • [30] Analysis of gentisic acid and related renal cell carcinoma biomarkers using reversed-phase liquid chromatography with water-rich mobile phases
    Dahal, Kaushalya Sharma
    Gamagedara, Sanjeewa
    Perera, Undugodage Don Nuwan
    Lavine, Barry K.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2019, 42 (19-20) : 681 - 687