Improved pH measurement of mobile phases in reversed-phase liquid chromatography

被引:3
|
作者
Heering, Agnes [1 ]
Lahe, Markus [1 ]
Vilbaste, Martin [1 ]
Saame, Jaan [1 ]
Samin, John Paulo [1 ]
Leito, Ivo [1 ]
机构
[1] Univ Tartu UT, Inst Chem, Ravila St 14a, EE-50411 Tartu, Estonia
关键词
MASS SPECTROMETRY; PK(A) VALUES; UNIFIED PH; GIBBS ENERGIES; SALT BRIDGE; SINGLE IONS; WATER; ACIDS; RETENTION; MIXTURES;
D O I
10.1039/d3an02029k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mobile phase pH is a critically important parameter in reversed-phase liquid chromatographic (RPLC) separations involving analytes that display acidic or basic properties in the pH range used for the mobile phase. The main problem in measuring mobile phase pH lies in the fact that RPLC mobile phases are typically aqueous-organic mixtures. In addition to experimental difficulties, the pH values refer to different aqueous-organic compositions that cannot be correctly compared. Given this situation, the unified pH (wabspH, also termed as ) based on the absolute chemical potential of the solvated proton has been proposed as a rigorous way of characterising mobile phase acidity that is fully inter-comparable between mobile phases of any composition. Here we report the wabspH values of 78 reversed-phase liquid chromatography-mass spectrometry mobile phases that were carefully measured by potential differences in a symmetric cell with two glass electrode half-cells and almost ideal ionic liquid triethylamylammonium bis((trifluoromethyl)sulfonyl)imide [N2225][NTf2] salt bridge with multiple overlapping measurements. The system of altogether 300 Delta wabspH values was anchored to the pH value of standard pH 7.00 aqueous buffer solution. The consistency standard deviation of the whole set of measurements was 0.09 pH units. In addition to the differential potentiometric reference method, simpler measurement methods that use double junction reference or double junction combined electrodes were tested and were found suitable for routine laboratories if high accuracy is not required. Mobile phase unified pH was investigated using several methods to provide pH values comparable between different mobile phase compositions. A double junction combined electrode filled with ionic liquid was tested for the first time.
引用
收藏
页码:1481 / 1488
页数:8
相关论文
共 50 条
  • [1] THE INFLUENCE OF MOBILE PHASE pH ON THE RETENTION AND SELECTIVITY OF RELATED BASIC COMPOUNDS IN REVERSED-PHASE LIQUID CHROMATOGRAPHY
    Galaon, Toma
    David, Victor
    REVUE ROUMAINE DE CHIMIE, 2012, 57 (02) : 131 - 140
  • [2] Mobile Phase Effects in Reversed-Phase and Hydrophilic Interaction Liquid Chromatography
    Jandera, Pavel
    Hajek, Tarns
    ADVANCES IN CHROMATOGRAPHY, VOL 57, 2021, 57 : 1 - 58
  • [3] IONIC LIQUIDS AS MOBILE PHASE ADDITIVES IN REVERSED-PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
    Flieger, J.
    Czajkowska-Zelazko, A.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (18) : 2224 - 2242
  • [4] Imidazoline type stationary phase for hydrophilic interaction chromatography and reversed-phase liquid chromatography
    Li, Yuanyuan
    Feng, Yaoyao
    Chen, Tong
    Zhang, Haixia
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (35) : 5987 - 5994
  • [5] Characterization of stationary phases for reversed-phase chromatography
    Molikova, Martina
    Jandera, Pavel
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (4-5) : 453 - 463
  • [6] A comprehensive two-dimensional normal-phase x reversed-phase liquid chromatography based on the modification of mobile phases
    Wei, Yuanlong
    Lan, Tao
    Tang, Tao
    Zhang, Lingyi
    Wang, Fengyun
    Li, Tong
    Du, Yiping
    Zhang, Weibing
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (44) : 7466 - 7471
  • [7] Unified pH Values of Liquid Chromatography Mobile Phases
    Suu, Agnes
    Jalukse, Lauri
    Liigand, Jaanus
    Kruve, Anneli
    Himmel, Daniel
    Krossing, Ingo
    Roses, Marti
    Leito, Ivo
    ANALYTICAL CHEMISTRY, 2015, 87 (05) : 2623 - 2630
  • [8] How Reversed-Phase Liquid Chromatography Works
    Schure, Mark R.
    Rafferty, Jake L.
    Zhang, Ling
    Siepmann, J. Ilja
    LC GC EUROPE, 2014, 27 (01) : 18 - +
  • [9] How Reversed-Phase Liquid Chromatography Works
    Schure, Mark R.
    Rafferty, Jake L.
    Zhang, Ling
    Siepmann, J. Ilja
    LC GC NORTH AMERICA, 2013, 31 (08) : 630 - 637
  • [10] Sorption Isotherms of Ternary Eluents in Reversed-Phase Liquid Chromatography
    Wang, Mei
    Mallette, Jennifer
    Parcher, Jon F.
    ANALYTICAL CHEMISTRY, 2009, 81 (03) : 984 - 990