Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

被引:9
|
作者
Hama, Dler Raouf [1 ]
Mahmood, Bayad Jaza [1 ]
机构
[1] Univ Sulaimani, Coll Dent, Dept Oral & Maxillofacial Surg, Madam Mitterrand St, Sulaymaniyah 46001, Iraq
来源
关键词
Computer-aided design; Cone-beam CT; Dental implant; COMPUTED-TOMOGRAPHY; ANTERIOR MAXILLA; RESTORATIONS; SURGEONS;
D O I
10.5051/jpis.2204700235
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.
引用
收藏
页码:388 / 401
页数:14
相关论文
共 18 条
  • [1] Free-Hand versus Surgical Guide Implant Placement
    Afshari, Aysooda
    Shahmohammadi, Rojin
    Mosaddad, Seyed Ali
    Pesteei, Ozra
    Hajmohammadi, Emran
    Rahbar, Mahdi
    Alam, Mostafa
    Abbasi, Kamyar
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2022, 2022
  • [2] Three-dimensional Accuracy of Angled Dental Implant Placement: A Comparison Study of the Dynamic Navigation System and Free-hand Method
    Ustek, Gunes Kenan
    Simsek, Hasan Onur
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2021, 22 : 119 - 128
  • [3] Accuracy of dental implant placement using augmented reality-based navigation, static computer assisted implant surgery, and the free-hand method: An in vitro study
    Kivovics, Marton
    Takacs, Anna
    Penzes, Dorottya
    Nemeth, Orsolya
    Mijiritsky, Eitan
    JOURNAL OF DENTISTRY, 2022, 119
  • [4] Accuracy of Implant Placement Using a CAD/CAM Surgical Guide: An In Vitro Study
    Nokar, Saeid
    Moslehifard, Elnaz
    Bahman, Tootiaii
    Bayanzadeh, Masoud
    Nasirpouri, Farzad
    Nokar, Arash
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (03) : 520 - 526
  • [5] ACCURACY OF THREE DIFFERENT TYPES OF STEREOLITHOGRAPHIC SURGICAL GUIDE IN IMPLANT PLACEMENT: AN IN VITRO STUDY
    Turbush, Sarah Katherine
    Turkyilmaz, Ilser
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 108 (03): : 181 - 188
  • [6] Influence of Metal Guide Sleeves on the Accuracy and Precision of Dental Implant Placement Using Guided Implant Surgery: An In Vitro Study
    Adams, Coleman R.
    Ammoun, Rami
    Deeb, George R.
    Bencharit, Sompop
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (01): : 62 - 70
  • [7] RESEARCH AND EDUCATION Accuracy of a custom two-piece surgical guide for all-on-four dental implant placement: An in vitro study
    Elnashoukaty, Hassan M.
    ElDakkak, Sherif
    Abdelhakim, Ahmed
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (01): : 101.e1 - 101.e9
  • [8] Comparative analysis of dental implant placement accuracy: Semi-active robotic versus free-hand techniques: A randomized controlled clinical trial
    Yang, Fan
    Chen, Jianping
    Cao, Ruijue
    Tang, Qingwei
    Liu, Haiyan
    Zheng, Yuchen
    Liu, BeiLei
    Huang, Min
    Wang, Zhenshi
    Ding, Yude
    Wang, Linhong
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (06) : 1149 - 1161
  • [9] Evaluation of the difference in accuracy between implant placement by virtual planning data and surgical guide templates versus the conventional free-hand method - a combined in vivo - in vitro technique using cone-beam CT (Part II)
    Nickenig, Hans-Joachim
    Wichmann, Manfred
    Hamel, Joerg
    Schlegel, Karl Andreas
    Eitner, Stephan
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2010, 38 (07) : 488 - 493
  • [10] Comparison of the accuracy of dental implant placement using static and dynamic computer-assisted systems: an in vitro study
    Zhou, Miao
    Zhou, Hui
    Li, Shu-Yi
    Zhu, Yi-Bo
    Geng, Yuan-Ming
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) : 343 - 348