The silicone metacarpophalangeal joint arthroplasty: An in-vitro analysis

被引:2
作者
Completo, A. [1 ]
Semitela, A. [1 ]
Fonseca, F. [2 ]
Nascimento, A. [2 ]
机构
[1] Univ Aveiro, Mech Engn Dept, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[2] Coimbra Univ Hosp, Orthopaed Dept, Coimbra, Portugal
关键词
Experimental strains; Strain gauges; Finite element analysis; MCP joint; MCPX-Preflex implant; Silicone metacarpophalangeal arthroplasty; IMPLANT ARTHROPLASTY; BONE; SWANSON; SURVIVORSHIP; FRACTURE;
D O I
10.1016/j.clinbiomech.2023.106120
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Silicone is still the gold standard implant in metacarpophalangeal arthroplasty. Whereas the clinical results are acceptable, in follow-ups with >10 years, high rates of implant fracture are common, and 5 to 7% of implants required revision. This work's purpose is to analyse the hypothesis that the joint flexion amplitude has a relevant effect on bone strain level, implant stress and bone-implant micromotion, which can reflect an increase in the risk of bone resorption/fatigue failure, implant fracture and osteolysis.Methods: To experimentally predict the cortical loading behaviour, composite metacarpals and proximal phalanges were used in intact and implanted states. A finite element model was developed to evaluate the structural behaviour of cancellous bone and implant. This model was validated by comparing cortical strain and load-displacement curve with experimental measurements.Findings: Bone strain changes between the intact and the implanted states showed a load transfer effect from the cortical to the cancellous bone that increases significantly with the flexion's amplitude rise. The peak implant stress occurred in the flexion amplitudes further away from the implant neutral angle. The highest implant pistoning motion and the highest phalanx cancellous-bone strain occurred simultaneously at the maximum flexion amplitude.Interpretation: Limiting joint flexion range will be helpful to reduce the strain-shielding effect on cortical bone, minimizing the overload effect on cancellous bone and decreasing the stress levels and the pistoning motion on the implant, ultimately contributing to the longevity of silicone arthroplasty.
引用
收藏
页数:8
相关论文
共 36 条
[1]   FORCES IN THE NORMAL AND ABNORMAL HAND [J].
AN, KN ;
CHAO, EY ;
COONEY, WP ;
LINSCHEID, RL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (02) :202-211
[2]  
[Anonymous], 2021, ASTM F1839-08
[3]  
Biddis E., 2004, INT J MECH MATER DES, V1, P317, DOI [10.1007/s10999-005-3308-3, DOI 10.1007/S10999-005-3308-3]
[4]   Long-term outcomes of silicone metacarpophalangeal arthroplasty: a longitudinal analysis of 325 cases [J].
Boe, Chelsea ;
Wagner, Eric ;
Rizzo, Marco .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (10) :1076-1082
[5]   My personal experience with arthroplasties in the hand and wrist over the past four decades [J].
Boeckstyns, Michel E. H. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2019, 44 (02) :129-137
[6]   A COMPARISON OF THE FATIGUE BEHAVIOR OF HUMAN TRABECULAR AND CORTICAL BONE TISSUE [J].
CHOI, K ;
GOLDSTEIN, SA .
JOURNAL OF BIOMECHANICS, 1992, 25 (12) :1371-1381
[7]   A new press-fit stem concept to reduce the risk of end-of-stem pain at revision TKA: A pre-clinical study [J].
Completo, A. ;
Fonseca, F. ;
Simoes, J. A. ;
Ramos, A. ;
Relvas, C. .
KNEE, 2012, 19 (05) :537-542
[8]   Experimental Evaluation of Strain Shielding in Distal Femur in Revision TKA [J].
Completo, A. ;
Simoes, J. A. ;
Fonseca, F. .
EXPERIMENTAL MECHANICS, 2008, 48 (06) :817-824
[9]   The many adaptations of bone [J].
Currey, JD .
JOURNAL OF BIOMECHANICS, 2003, 36 (10) :1487-1495
[10]   SWANSON SILICONE FINGER JOINT IMPLANTS - A REVIEW OF THE LITERATURE REGARDING LONG-TERM COMPLICATIONS [J].
FOLIART, DE .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (03) :445-449