Robot-assisted pyeloplasty for ureteropelvic junction obstruction: initial experience with the novel avatera system

被引:4
作者
Kallidonis, Panagiotis [1 ]
Tatanis, Vasileios [1 ]
Peteinaris, Angelis [1 ]
Katsakiori, Paraskevi [1 ]
Gkeka, Kristiana [1 ]
Faitatziadis, Solon [1 ]
Vagionis, Athanasios [1 ]
Vrettos, Theofanis [2 ]
Stolzenburg, Jens-Uwe [3 ]
Liatsikos, Evangelos [1 ,4 ,5 ]
机构
[1] Univ Patras, Dept Urol, Patras, Greece
[2] Univ Patras, Dept Anesthesiol & ICU, Patras, Greece
[3] Univ Hosp Leipzig, Dept Urol, Leipzig, Germany
[4] Med Univ Vienna, Dept Urol, Vienna, Austria
[5] Univ Patras, Dept Urol, Med Sch, Patras 26500, Greece
关键词
Avatera system; Robot-assisted pyeloplasty; Pyeloplasty; Ureteropelvic junction obstruction; HYNES DISMEMBERED PYELOPLASTY; LAPAROSCOPIC PYELOPLASTY;
D O I
10.1007/s00345-023-04586-7
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
PurposeThis pilot study was designed to interpret the technically specific features of the avatera robotic system and present our initial experience with this novel platform in robot-assisted pyeloplasty (RAP).MethodsA single-center prospective study was conducted including all patients who underwent RAP with the avatera robotic system from June 2022 to October 2022 in our Department. Transperitoneal robot-assisted dismembered pyeloplasty was performed in all cases. The trocar placement and the surgical technique were similar in all patients. The successful completion of the procedures, operation time (including draping, docking and console time), decrease in hemoglobin postoperatively, and presence of any complications were the study's primary endpoints.ResultsIn total, nine patients underwent RAP using the avatera system. All procedures were successfully completed. The draping of the robotic unit was completed in a median time of 10 min (range 7-15), while the median docking time was 17 min (range 10-24). The median console time was 88 min (range 78-116) and no complications were noticed. The median hemoglobin drop was calculated to 0.7 g/dL (range 0.4-1). During the mean follow-up of 9.33 & PLUSMN; 2.78 months, no late postoperative complications were noticed.ConclusionThe early outcomes of the use of the novel avatera system in RAP are presented. All operations were successfully completed with safety and efficacy, without complications or significant blood loss.
引用
收藏
页码:3155 / 3160
页数:6
相关论文
共 50 条
  • [31] Robot-assisted laparoscopic pyeloplasty is a valid option for ureteropelvic junction obstruction repair in adults with congenital renal abnormalities: a case series study
    Sarah Razavi
    Joshua Babbin
    Douglas Dahl
    BMC Urology, 23
  • [32] Robot assisted laparoscopic pyeloplasty in patients of ureteropelvic junction obstruction with previously failed open surgical repair
    Hemal, Ashok K.
    Mishra, Saurabh
    Mukharjee, Satydip
    Suryavanshi, Manav
    INTERNATIONAL JOURNAL OF UROLOGY, 2008, 15 (08) : 744 - 746
  • [33] Comparison of open, laparoscopic and robot-assisted pyeloplasty for pelviureteric junction obstruction in adult patients
    Rasool, Shahnawaz
    Singh, Mahendra
    Jain, Saurabh
    Chaddha, Sudhir
    Tyagi, Vipin
    Pahwa, Mrinal
    Pandey, Himanshu
    JOURNAL OF ROBOTIC SURGERY, 2020, 14 (02) : 325 - 329
  • [34] Laparoscopic dismembered pyeloplasty for ureteropelvic junction obstruction in children
    Kojima, Yoshiyuki
    Sasaki, Shoichi
    Mizuno, Kentaro
    Tozawa, Keiichi
    Hayashi, Yutaro
    Kohri, Kenjiro
    INTERNATIONAL JOURNAL OF UROLOGY, 2009, 16 (05) : 472 - 476
  • [35] Transperitoneal laparoscopic pyeloplasty in the treatment of ureteropelvic junction obstruction
    Gomez Rivas, Juan
    Alonso y Gregorio, Sergio
    Portilla Eastmond, Maria A.
    Tabernero Gomez, Angel
    Cisneros Ledo, Jesus
    Hidalgo Togores, Luis
    de la Pena Barthel, Jesus Javier
    CENTRAL EUROPEAN JOURNAL OF UROLOGY, 2013, 66 (03) : 361 - 365
  • [36] Comparison of open, laparoscopic and robot-assisted pyeloplasty for pelviureteric junction obstruction in adult patients
    Shahnawaz Rasool
    Mahendra Singh
    Saurabh Jain
    Sudhir Chaddha
    Vipin Tyagi
    Mrinal Pahwa
    Himanshu Pandey
    Journal of Robotic Surgery, 2020, 14 : 325 - 329
  • [37] Single-Port vs Multiple-Port Robot-Assisted Laparoscopic Pyeloplasty for the Treatment of Ureteropelvic Junction Obstruction: A Systematic Review and Meta-Analysis
    Gu, Li
    Li, Yijian
    Li, Xurui
    Liu, Wentao
    JOURNAL OF ENDOUROLOGY, 2023, 37 (06) : 681 - 687
  • [38] Analysis of a large single-center experience with robot-assisted pyeloplasty
    Tobis, Scott
    Venigalla, Sriram
    Balakumaran, Kathir
    Scosyrev, Emelian
    Lloyd, Granville L.
    Golijanin, Dragan J.
    Joseph, Jean V.
    Rashid, Hani
    Wu, Guan
    INTERNATIONAL JOURNAL OF UROLOGY, 2013, 20 (02) : 230 - 234
  • [39] Experience with laparoscopic pyeloplasty for treating ureteropelvic junction obstruction in children.: Technique and results
    Subotic, S.
    Schulze, M.
    Goezen, A.
    Rassweiler, J.
    Teber, D.
    UROLOGE, 2008, 47 (06): : 718 - 723
  • [40] Robot-assisted and laparoscopic pyeloplasty
    Ignacio Pascual-Piedrola, Juan
    Merino-Narro, Imanol
    Hevia-Suarez, Mateo
    Javier Ancizu-Viarckert, Francisco
    Garcia-Cortes, Angel
    Domenech-Lopez, Pablo
    ARCHIVOS ESPANOLES DE UROLOGIA, 2017, 70 (04): : 454 - 461